纯己丙肾上腺素、药物制剂和生物样品的流动注射电位测定。

Rasha M El-Nashar
{"title":"纯己丙肾上腺素、药物制剂和生物样品的流动注射电位测定。","authors":"Rasha M El-Nashar","doi":"10.1155/2008/586310","DOIUrl":null,"url":null,"abstract":"<p><p>Different hexoprenaline (Hx(2)SO(4)) conventional and coated wire electrodes were constructed and evaluated. Membranes were based on hexoprenalinium phosphotungstate (Hx-PTA) and hexporenalinium phosphomolybdate (Hx-PMA). The electrodes were fully characterized in terms of their composition, response time, life span, pH, and temperature and then were applied to the potentiometric determination of the hexoprenalinium ion in its pure state, pharmaceutical preparations, and biological samples, urine and plasma, under batch and flow injection conditions. The selectivity of the electrodes towards many inorganic cations, sugars, amino acids, and some other brochodilatures of close chemical composition was also tested.</p>","PeriodicalId":15248,"journal":{"name":"Journal of Automated Methods & Management in Chemistry","volume":"2008 ","pages":"586310"},"PeriodicalIF":0.0000,"publicationDate":"2008-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1155/2008/586310","citationCount":"7","resultStr":"{\"title\":\"Flow injection potentiometric assay of hexoprenaline in its pure state, pharmaceutical preparations, and biological samples.\",\"authors\":\"Rasha M El-Nashar\",\"doi\":\"10.1155/2008/586310\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Different hexoprenaline (Hx(2)SO(4)) conventional and coated wire electrodes were constructed and evaluated. Membranes were based on hexoprenalinium phosphotungstate (Hx-PTA) and hexporenalinium phosphomolybdate (Hx-PMA). The electrodes were fully characterized in terms of their composition, response time, life span, pH, and temperature and then were applied to the potentiometric determination of the hexoprenalinium ion in its pure state, pharmaceutical preparations, and biological samples, urine and plasma, under batch and flow injection conditions. The selectivity of the electrodes towards many inorganic cations, sugars, amino acids, and some other brochodilatures of close chemical composition was also tested.</p>\",\"PeriodicalId\":15248,\"journal\":{\"name\":\"Journal of Automated Methods & Management in Chemistry\",\"volume\":\"2008 \",\"pages\":\"586310\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2008-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1155/2008/586310\",\"citationCount\":\"7\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Automated Methods & Management in Chemistry\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1155/2008/586310\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Automated Methods & Management in Chemistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1155/2008/586310","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 7

摘要

构建不同的己丙肾上腺素(Hx(2)SO(4))常规和涂覆丝电极并进行评价。膜是基于磷酸钨酸六丙二钠(Hx-PTA)和磷酸钼酸六丙二钠(Hx-PMA)。电极在组成、响应时间、寿命、pH值和温度方面进行了充分的表征,然后应用于纯己戊二钠离子、药物制剂、生物样品、尿液和血浆、批量和流动注射条件下的电位测定。还测试了电极对许多无机阳离子、糖、氨基酸和其他一些化学成分相近的溴化物的选择性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Flow injection potentiometric assay of hexoprenaline in its pure state, pharmaceutical preparations, and biological samples.

Flow injection potentiometric assay of hexoprenaline in its pure state, pharmaceutical preparations, and biological samples.

Flow injection potentiometric assay of hexoprenaline in its pure state, pharmaceutical preparations, and biological samples.

Flow injection potentiometric assay of hexoprenaline in its pure state, pharmaceutical preparations, and biological samples.

Different hexoprenaline (Hx(2)SO(4)) conventional and coated wire electrodes were constructed and evaluated. Membranes were based on hexoprenalinium phosphotungstate (Hx-PTA) and hexporenalinium phosphomolybdate (Hx-PMA). The electrodes were fully characterized in terms of their composition, response time, life span, pH, and temperature and then were applied to the potentiometric determination of the hexoprenalinium ion in its pure state, pharmaceutical preparations, and biological samples, urine and plasma, under batch and flow injection conditions. The selectivity of the electrodes towards many inorganic cations, sugars, amino acids, and some other brochodilatures of close chemical composition was also tested.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
审稿时长
>12 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信