Liang Wei, Xinshen Zhang, Yichun Dai, Jin Huang, Yong-Hong Xie, Kai Xiao
{"title":"自然水中微量锌的在线富集和测定。","authors":"Liang Wei, Xinshen Zhang, Yichun Dai, Jin Huang, Yong-Hong Xie, Kai Xiao","doi":"10.1155/2008/742319","DOIUrl":null,"url":null,"abstract":"<p><p>A simple, sensitive, reliable and flexible flow injection spectrophotometric method is proposed for on-line preconcentration and determination of trace amounts of zinc in water. At the presence of Tween-80 in pH 9.3 buffer solutions, the shade of color of Zn (II)-PAN complex is in a linear relation to the zinc amount at the point of the maximum absorption peak of 560 nm. The optimal experimental conditions, including reaction conditions and preconcentration conditions, had been obtained. The linear range of the proposed method was between 2.0 and 360 mug L(-1) and the detection limit was 0.42 mug L(-1). The relative standard deviation was 3.55% and 2.14% for 5.0 mug L(-1) and 50 mug L(-1) of zinc standard solution (n = 8). The method had been successfully applied to zinc determination in water samples and the analytical results were satisfactory.</p>","PeriodicalId":15248,"journal":{"name":"Journal of Automated Methods & Management in Chemistry","volume":"2008 ","pages":"742319"},"PeriodicalIF":0.0000,"publicationDate":"2008-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1155/2008/742319","citationCount":"7","resultStr":"{\"title\":\"Online preconcentration and determination of trace amounts of zinc in nature waters.\",\"authors\":\"Liang Wei, Xinshen Zhang, Yichun Dai, Jin Huang, Yong-Hong Xie, Kai Xiao\",\"doi\":\"10.1155/2008/742319\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>A simple, sensitive, reliable and flexible flow injection spectrophotometric method is proposed for on-line preconcentration and determination of trace amounts of zinc in water. At the presence of Tween-80 in pH 9.3 buffer solutions, the shade of color of Zn (II)-PAN complex is in a linear relation to the zinc amount at the point of the maximum absorption peak of 560 nm. The optimal experimental conditions, including reaction conditions and preconcentration conditions, had been obtained. The linear range of the proposed method was between 2.0 and 360 mug L(-1) and the detection limit was 0.42 mug L(-1). The relative standard deviation was 3.55% and 2.14% for 5.0 mug L(-1) and 50 mug L(-1) of zinc standard solution (n = 8). The method had been successfully applied to zinc determination in water samples and the analytical results were satisfactory.</p>\",\"PeriodicalId\":15248,\"journal\":{\"name\":\"Journal of Automated Methods & Management in Chemistry\",\"volume\":\"2008 \",\"pages\":\"742319\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2008-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1155/2008/742319\",\"citationCount\":\"7\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Automated Methods & Management in Chemistry\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1155/2008/742319\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Automated Methods & Management in Chemistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1155/2008/742319","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Online preconcentration and determination of trace amounts of zinc in nature waters.
A simple, sensitive, reliable and flexible flow injection spectrophotometric method is proposed for on-line preconcentration and determination of trace amounts of zinc in water. At the presence of Tween-80 in pH 9.3 buffer solutions, the shade of color of Zn (II)-PAN complex is in a linear relation to the zinc amount at the point of the maximum absorption peak of 560 nm. The optimal experimental conditions, including reaction conditions and preconcentration conditions, had been obtained. The linear range of the proposed method was between 2.0 and 360 mug L(-1) and the detection limit was 0.42 mug L(-1). The relative standard deviation was 3.55% and 2.14% for 5.0 mug L(-1) and 50 mug L(-1) of zinc standard solution (n = 8). The method had been successfully applied to zinc determination in water samples and the analytical results were satisfactory.