Eva Ródenas-Torralba, Fábio R P Rocha, Boaventura F Reis, Angel Morales-Rubio, Miguel de la Guardia
{"title":"用于光度环境测量的多换向流系统的评价。","authors":"Eva Ródenas-Torralba, Fábio R P Rocha, Boaventura F Reis, Angel Morales-Rubio, Miguel de la Guardia","doi":"10.1155/JAMMC/2006/20384","DOIUrl":null,"url":null,"abstract":"<p><p>A portable flow analysis instrument is described for in situ photometric measurements. This system is based on light-emitting diodes (LEDs) and a photodiode detector, coupled to a multipumping flow system. The whole equipment presents dimensions of 25 cm x 22 cm x 10 cm, weighs circa 3 kg, and costs 650 euro. System performance was evaluated for different chemistries without changing hardware configuration for determinations of (i) Fe(3+) with SCN(-), (ii) iodometric nitrite determination, (iii) phenol with sodium nitroprusside, and (iv) 1-naphthol-N-methylcarbamate (carbaryl) with p-aminophenol. The detection limits were estimated as 22, 60, 25, and 60 ng mL (-1) for iron, nitrite, phenol, and carbaryl at the 99.7% confidence level with RSD of 2.3, 1.0, 1.8, and 0.8%, respectively. Reagent and waste volumes were lower than those obtained by flow systems with continuous reagent addition. Sampling rates of 100, 110, 65, and 72 determinations per hour were achieved for iron, nitrite, phenol, and carbaryl determinations.</p>","PeriodicalId":15248,"journal":{"name":"Journal of Automated Methods & Management in Chemistry","volume":"2006 ","pages":"20384"},"PeriodicalIF":0.0000,"publicationDate":"2006-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1155/JAMMC/2006/20384","citationCount":"40","resultStr":"{\"title\":\"Evaluation of a multicommuted flow system for photometric environmental measurements.\",\"authors\":\"Eva Ródenas-Torralba, Fábio R P Rocha, Boaventura F Reis, Angel Morales-Rubio, Miguel de la Guardia\",\"doi\":\"10.1155/JAMMC/2006/20384\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>A portable flow analysis instrument is described for in situ photometric measurements. This system is based on light-emitting diodes (LEDs) and a photodiode detector, coupled to a multipumping flow system. The whole equipment presents dimensions of 25 cm x 22 cm x 10 cm, weighs circa 3 kg, and costs 650 euro. System performance was evaluated for different chemistries without changing hardware configuration for determinations of (i) Fe(3+) with SCN(-), (ii) iodometric nitrite determination, (iii) phenol with sodium nitroprusside, and (iv) 1-naphthol-N-methylcarbamate (carbaryl) with p-aminophenol. The detection limits were estimated as 22, 60, 25, and 60 ng mL (-1) for iron, nitrite, phenol, and carbaryl at the 99.7% confidence level with RSD of 2.3, 1.0, 1.8, and 0.8%, respectively. Reagent and waste volumes were lower than those obtained by flow systems with continuous reagent addition. Sampling rates of 100, 110, 65, and 72 determinations per hour were achieved for iron, nitrite, phenol, and carbaryl determinations.</p>\",\"PeriodicalId\":15248,\"journal\":{\"name\":\"Journal of Automated Methods & Management in Chemistry\",\"volume\":\"2006 \",\"pages\":\"20384\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2006-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1155/JAMMC/2006/20384\",\"citationCount\":\"40\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Automated Methods & Management in Chemistry\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1155/JAMMC/2006/20384\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Automated Methods & Management in Chemistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1155/JAMMC/2006/20384","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 40
摘要
介绍了一种用于原位光度测量的便携式流量分析仪器。该系统是基于发光二极管(led)和光电二极管检测器,耦合到一个多泵浦流系统。整个设备的尺寸为25厘米× 22厘米× 10厘米,重约3公斤,价格为650欧元。在不改变硬件配置的情况下,对不同化学物质的系统性能进行了评估,包括(i)用SCN(-)测定Fe(3+), (ii)用碘量测定亚硝酸盐,(iii)用硝普钠测定苯酚,(iv)用对氨基酚测定1-萘酚-n -甲基氨基甲酸酯(西威因)。铁、亚硝酸盐、苯酚和西维因的检出限分别为22、60、25和60 ng mL(-1),置信水平为99.7%,RSD分别为2.3、1.0、1.8和0.8%。试剂和废物体积低于连续添加试剂的流动系统。铁、亚硝酸盐、苯酚和西维因的采样率分别为每小时100、110、65和72次。
Evaluation of a multicommuted flow system for photometric environmental measurements.
A portable flow analysis instrument is described for in situ photometric measurements. This system is based on light-emitting diodes (LEDs) and a photodiode detector, coupled to a multipumping flow system. The whole equipment presents dimensions of 25 cm x 22 cm x 10 cm, weighs circa 3 kg, and costs 650 euro. System performance was evaluated for different chemistries without changing hardware configuration for determinations of (i) Fe(3+) with SCN(-), (ii) iodometric nitrite determination, (iii) phenol with sodium nitroprusside, and (iv) 1-naphthol-N-methylcarbamate (carbaryl) with p-aminophenol. The detection limits were estimated as 22, 60, 25, and 60 ng mL (-1) for iron, nitrite, phenol, and carbaryl at the 99.7% confidence level with RSD of 2.3, 1.0, 1.8, and 0.8%, respectively. Reagent and waste volumes were lower than those obtained by flow systems with continuous reagent addition. Sampling rates of 100, 110, 65, and 72 determinations per hour were achieved for iron, nitrite, phenol, and carbaryl determinations.