心力衰竭患者心肺运动试验结果的规范化和预测。

Robert L Bard, John M Nicklas
{"title":"心力衰竭患者心肺运动试验结果的规范化和预测。","authors":"Robert L Bard,&nbsp;John M Nicklas","doi":"10.1097/00008483-200611000-00008","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Cardiopulmonary exercise testing is a common prognostic tool in heart failure, yet it is not standardized. The purpose of this study was to evaluate a means of standardizing oxygen consumption (VO(2)) measurement and to evaluate the ability to predict peak VO(2) from submaximal exercise.</p><p><strong>Methods: </strong>Fifty consecutive exercise tests with a respiratory exchange ratio > or =1.10 were evaluated. VO(2) was graphed against respiratory exchange ratio and the peak VO(2) was determined with logarithmic, linear, power, and exponential regression lines. To predict a peak VO(2), each patient's submaximal exercise data (respiratory exchange ratio < or =0.98) were fitted to each regression line. The mean of the last 30 seconds of un-averaged breath-by-breath data was used as the reference value. Peak VO(2) assessments are also provided from the metabolic cart, a rolling time average, and the graphical method.</p><p><strong>Results: </strong>Logarithmic regression best standardized peak VO(2). Mean absolute bias (mL x kg x min) was 0.60 +/- 0.44 for logarithmic, 0.61 +/- 0.47 for linear, 0.85 +/- 0.67 for power, and 1.44 +/- 2.22 for exponential. The mean absolute bias between the peak logarithmic predicted VO(2) and the reference peak VO(2) was 1.62 +/- 1.20 mL x kg x min (9.5% of the peak VO(2)).</p><p><strong>Conclusion: </strong>Among the methods studied, logarithmic regression analysis was the best method to standardize and predict peak VO(2) in this cohort of patients with heart failure.</p>","PeriodicalId":15203,"journal":{"name":"Journal of Cardiopulmonary Rehabilitation","volume":"26 6","pages":"384-90"},"PeriodicalIF":0.0000,"publicationDate":"2006-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1097/00008483-200611000-00008","citationCount":"0","resultStr":"{\"title\":\"Standardizing and predicting results from cardiopulmonary exercise testing in patients with heart failure.\",\"authors\":\"Robert L Bard,&nbsp;John M Nicklas\",\"doi\":\"10.1097/00008483-200611000-00008\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>Cardiopulmonary exercise testing is a common prognostic tool in heart failure, yet it is not standardized. The purpose of this study was to evaluate a means of standardizing oxygen consumption (VO(2)) measurement and to evaluate the ability to predict peak VO(2) from submaximal exercise.</p><p><strong>Methods: </strong>Fifty consecutive exercise tests with a respiratory exchange ratio > or =1.10 were evaluated. VO(2) was graphed against respiratory exchange ratio and the peak VO(2) was determined with logarithmic, linear, power, and exponential regression lines. To predict a peak VO(2), each patient's submaximal exercise data (respiratory exchange ratio < or =0.98) were fitted to each regression line. The mean of the last 30 seconds of un-averaged breath-by-breath data was used as the reference value. Peak VO(2) assessments are also provided from the metabolic cart, a rolling time average, and the graphical method.</p><p><strong>Results: </strong>Logarithmic regression best standardized peak VO(2). Mean absolute bias (mL x kg x min) was 0.60 +/- 0.44 for logarithmic, 0.61 +/- 0.47 for linear, 0.85 +/- 0.67 for power, and 1.44 +/- 2.22 for exponential. The mean absolute bias between the peak logarithmic predicted VO(2) and the reference peak VO(2) was 1.62 +/- 1.20 mL x kg x min (9.5% of the peak VO(2)).</p><p><strong>Conclusion: </strong>Among the methods studied, logarithmic regression analysis was the best method to standardize and predict peak VO(2) in this cohort of patients with heart failure.</p>\",\"PeriodicalId\":15203,\"journal\":{\"name\":\"Journal of Cardiopulmonary Rehabilitation\",\"volume\":\"26 6\",\"pages\":\"384-90\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2006-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1097/00008483-200611000-00008\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Cardiopulmonary Rehabilitation\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1097/00008483-200611000-00008\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Cardiopulmonary Rehabilitation","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1097/00008483-200611000-00008","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

目的:心肺运动试验是一种常见的心衰预后工具,但尚未标准化。本研究的目的是评估一种标准化的耗氧量(VO(2))测量方法,并评估从次最大运动中预测VO(2)峰值的能力。方法:对50例呼吸交换比>或=1.10的连续运动试验进行评价。将VO(2)与呼吸交换比作图,并采用对数、线性、功率和指数回归线确定VO(2)峰值。为了预测VO峰值(2),将每个患者的次最大运动数据(呼吸交换比<或=0.98)拟合到每条回归线上。最后30秒非平均呼吸数据的平均值被用作参考值。峰值VO(2)评估也提供了从代谢车,滚动时间平均值和图形方法。结果:对数回归最佳标准化峰值VO(2)。平均绝对偏差(mL x kg x min)对数为0.60 +/- 0.44,线性为0.61 +/- 0.47,功率为0.85 +/- 0.67,指数为1.44 +/- 2.22。峰值对数预测VO(2)与参考峰VO(2)之间的平均绝对偏差为1.62±1.20 mL × kg × min(峰值VO(2)的9.5%)。结论:在研究的方法中,对数回归分析是标准化和预测该心衰患者VO(2)峰值的最佳方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Standardizing and predicting results from cardiopulmonary exercise testing in patients with heart failure.

Purpose: Cardiopulmonary exercise testing is a common prognostic tool in heart failure, yet it is not standardized. The purpose of this study was to evaluate a means of standardizing oxygen consumption (VO(2)) measurement and to evaluate the ability to predict peak VO(2) from submaximal exercise.

Methods: Fifty consecutive exercise tests with a respiratory exchange ratio > or =1.10 were evaluated. VO(2) was graphed against respiratory exchange ratio and the peak VO(2) was determined with logarithmic, linear, power, and exponential regression lines. To predict a peak VO(2), each patient's submaximal exercise data (respiratory exchange ratio < or =0.98) were fitted to each regression line. The mean of the last 30 seconds of un-averaged breath-by-breath data was used as the reference value. Peak VO(2) assessments are also provided from the metabolic cart, a rolling time average, and the graphical method.

Results: Logarithmic regression best standardized peak VO(2). Mean absolute bias (mL x kg x min) was 0.60 +/- 0.44 for logarithmic, 0.61 +/- 0.47 for linear, 0.85 +/- 0.67 for power, and 1.44 +/- 2.22 for exponential. The mean absolute bias between the peak logarithmic predicted VO(2) and the reference peak VO(2) was 1.62 +/- 1.20 mL x kg x min (9.5% of the peak VO(2)).

Conclusion: Among the methods studied, logarithmic regression analysis was the best method to standardize and predict peak VO(2) in this cohort of patients with heart failure.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信