{"title":"精浆中α -葡萄糖苷酶测定的标准化和质量控制。","authors":"J-C Lu, H-R Xu, F Chen, Y-F Huang, N-Q Lu","doi":"10.1080/01485010600822705","DOIUrl":null,"url":null,"abstract":"<p><p>We attempted to provide an instruction for the standardization of alpha-glucosidase level determination and quality controls within the same laboratory and among different laboratories. Each of 51 semen samples was divided into two aliquots, centrifuging at 1000 g for 10 min or 3000 g for 15 min. The alpha-glucosidase level and sperm concentration of each sample were assayed. The alpha-glucosidase level in seminal plasma obtained at 3000 g for 15 min centrifugation was significantly lower than that at 1000 g for 10 min (p = 0.001). An additional 6 samples of seminal plasma with or without phenylmethylsulfonyl fluoride (PMSF), obtained at 3000 g for 15 min centrifugation, were frozen for 20 days, and each of 6 samples was determined for their alpha-glucosidase levels after thawing every other day. There was no significant difference between alpha-glucosidase levels in seminal plasma regardless of the presence of PMSF. The alpha-glucosidase level increased with the length of abstinence period. In conclusion, centrifugal velocity and abstinence time should be standardized in the alpha-glucosidase determination. Frozen seminal plasma may serve as the sample for quality control among clinical laboratories.</p>","PeriodicalId":8143,"journal":{"name":"Archives of andrology","volume":"52 6","pages":"447-53"},"PeriodicalIF":0.0000,"publicationDate":"2006-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1080/01485010600822705","citationCount":"7","resultStr":"{\"title\":\"Standardization and quality control for the determination of alpha-glucosidase in seminal plasma.\",\"authors\":\"J-C Lu, H-R Xu, F Chen, Y-F Huang, N-Q Lu\",\"doi\":\"10.1080/01485010600822705\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>We attempted to provide an instruction for the standardization of alpha-glucosidase level determination and quality controls within the same laboratory and among different laboratories. Each of 51 semen samples was divided into two aliquots, centrifuging at 1000 g for 10 min or 3000 g for 15 min. The alpha-glucosidase level and sperm concentration of each sample were assayed. The alpha-glucosidase level in seminal plasma obtained at 3000 g for 15 min centrifugation was significantly lower than that at 1000 g for 10 min (p = 0.001). An additional 6 samples of seminal plasma with or without phenylmethylsulfonyl fluoride (PMSF), obtained at 3000 g for 15 min centrifugation, were frozen for 20 days, and each of 6 samples was determined for their alpha-glucosidase levels after thawing every other day. There was no significant difference between alpha-glucosidase levels in seminal plasma regardless of the presence of PMSF. The alpha-glucosidase level increased with the length of abstinence period. In conclusion, centrifugal velocity and abstinence time should be standardized in the alpha-glucosidase determination. Frozen seminal plasma may serve as the sample for quality control among clinical laboratories.</p>\",\"PeriodicalId\":8143,\"journal\":{\"name\":\"Archives of andrology\",\"volume\":\"52 6\",\"pages\":\"447-53\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2006-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1080/01485010600822705\",\"citationCount\":\"7\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Archives of andrology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1080/01485010600822705\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Archives of andrology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/01485010600822705","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Standardization and quality control for the determination of alpha-glucosidase in seminal plasma.
We attempted to provide an instruction for the standardization of alpha-glucosidase level determination and quality controls within the same laboratory and among different laboratories. Each of 51 semen samples was divided into two aliquots, centrifuging at 1000 g for 10 min or 3000 g for 15 min. The alpha-glucosidase level and sperm concentration of each sample were assayed. The alpha-glucosidase level in seminal plasma obtained at 3000 g for 15 min centrifugation was significantly lower than that at 1000 g for 10 min (p = 0.001). An additional 6 samples of seminal plasma with or without phenylmethylsulfonyl fluoride (PMSF), obtained at 3000 g for 15 min centrifugation, were frozen for 20 days, and each of 6 samples was determined for their alpha-glucosidase levels after thawing every other day. There was no significant difference between alpha-glucosidase levels in seminal plasma regardless of the presence of PMSF. The alpha-glucosidase level increased with the length of abstinence period. In conclusion, centrifugal velocity and abstinence time should be standardized in the alpha-glucosidase determination. Frozen seminal plasma may serve as the sample for quality control among clinical laboratories.