{"title":"【化妆品中二硫化硒等禁用成分分析研究】。","authors":"Tadashi Uchino, Yoshiaki Ikarashi, Hiroshi Tokunaga","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Selenium disulfide is one kind of prohibited ingredients in cosmetics by the Japanese Pharmaceutical Affairs Act. We established the analytical method for selenium disulfide in cosmetics by ICP-MS. Selenium disulfide of 20 mg was put into a teflon vessel. After adding 5 ml of concentrated nitric acid and 2 ml of the shampoo into the teflon vessel, the mixture was digested with microwave-oven. After digesting, the mixture was made up to 25 ml with milliQ water and then it was filtrated through a milli-pore membrane (0.45 micro). After filtration, the solution was diluted with 7% of nitric acid and used as the test solution. The test solution of 100 microl was analyzed by ICP-MS (HP-4500, monitoring mass 82). The working curve from 10 to 1000 microg/l showed a linear line between the concentrations of selenium and the peak areas. Detection limit of selenium disulfide is 22 microg/l. There was no effect of the ingredients in the shampoo on selenium disulfide determination.</p>","PeriodicalId":35462,"journal":{"name":"Bulletin of National Institute of Health Sciences","volume":" 124","pages":"49-52"},"PeriodicalIF":0.0000,"publicationDate":"2006-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"[Studies for analyzing the prohibited ingredients such as selenium disulfide in cosmetics].\",\"authors\":\"Tadashi Uchino, Yoshiaki Ikarashi, Hiroshi Tokunaga\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Selenium disulfide is one kind of prohibited ingredients in cosmetics by the Japanese Pharmaceutical Affairs Act. We established the analytical method for selenium disulfide in cosmetics by ICP-MS. Selenium disulfide of 20 mg was put into a teflon vessel. After adding 5 ml of concentrated nitric acid and 2 ml of the shampoo into the teflon vessel, the mixture was digested with microwave-oven. After digesting, the mixture was made up to 25 ml with milliQ water and then it was filtrated through a milli-pore membrane (0.45 micro). After filtration, the solution was diluted with 7% of nitric acid and used as the test solution. The test solution of 100 microl was analyzed by ICP-MS (HP-4500, monitoring mass 82). The working curve from 10 to 1000 microg/l showed a linear line between the concentrations of selenium and the peak areas. Detection limit of selenium disulfide is 22 microg/l. There was no effect of the ingredients in the shampoo on selenium disulfide determination.</p>\",\"PeriodicalId\":35462,\"journal\":{\"name\":\"Bulletin of National Institute of Health Sciences\",\"volume\":\" 124\",\"pages\":\"49-52\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2006-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Bulletin of National Institute of Health Sciences\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Bulletin of National Institute of Health Sciences","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
[Studies for analyzing the prohibited ingredients such as selenium disulfide in cosmetics].
Selenium disulfide is one kind of prohibited ingredients in cosmetics by the Japanese Pharmaceutical Affairs Act. We established the analytical method for selenium disulfide in cosmetics by ICP-MS. Selenium disulfide of 20 mg was put into a teflon vessel. After adding 5 ml of concentrated nitric acid and 2 ml of the shampoo into the teflon vessel, the mixture was digested with microwave-oven. After digesting, the mixture was made up to 25 ml with milliQ water and then it was filtrated through a milli-pore membrane (0.45 micro). After filtration, the solution was diluted with 7% of nitric acid and used as the test solution. The test solution of 100 microl was analyzed by ICP-MS (HP-4500, monitoring mass 82). The working curve from 10 to 1000 microg/l showed a linear line between the concentrations of selenium and the peak areas. Detection limit of selenium disulfide is 22 microg/l. There was no effect of the ingredients in the shampoo on selenium disulfide determination.