Mehmet Fuat Alakus, Mehtap Caglayan, Nazım Ekin, Hasan Oncul, Esref Arac, Umut Dag, Halit Diri
{"title":"有无Kayser-Fleischer环的Wilson病患者角膜地形学和密度特性的研究。","authors":"Mehmet Fuat Alakus, Mehtap Caglayan, Nazım Ekin, Hasan Oncul, Esref Arac, Umut Dag, Halit Diri","doi":"10.1186/s40662-021-00231-9","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>To investigate the topographic measurements and densitometry of corneas in Wilson's disease (WD) patients with or without a Kayser-Fleischer ring (KF-r) compared to healthy individuals.</p><p><strong>Methods: </strong>This cross-sectional study included 20 WD patients without a KF-r (group I), 18 WD patients with a KF-r (group II), and 20 age-matched controls (group III). The Pentacam high resolution imaging system is used to determine corneal topographic measurements and densitometry.</p><p><strong>Results: </strong>Mean age for groups I, II and III was 25.40 ± 6.43 years (14-36 years), 25.38 ± 6.96 years (16-39 years), 23.60 ± 6.56 years (17-35 years), respectively (P = 0.623). There was no significant difference between the groups in terms of the anterior corneal densitometry values (P > 0.05), while the 6-10 mm and 10-12 mm mid stroma and the 2-6 mm, 6-10 mm, and 10-12 mm posterior corneal densitometry values in group II were significantly higher than those in groups I and III (for all values, P < 0.05). However, the 10-12 mm posterior corneal densitometry values in group I were also significantly higher than those in group III (P = 0.038). The central corneal thickness (CCT), thinnest corneal thickness (tCT), and corneal volume (CV) values in groups I and II were significantly lower than those in group III (for CCT values, P = 0.011 and P = 0.009; for tCT values, P = 0.010 and P = 0.005; for CV values, P = 0.043 and P = 0.029).</p><p><strong>Conclusion: </strong>In WD patients with a KF-r, corneal transparency decreased in the peripheral posterior and mid stromal corneal layers; for these patients, corneal transparency may be impaired not only in the peripheral cornea but also in the paracentral cornea.</p>","PeriodicalId":520624,"journal":{"name":"Eye and vision (London, England)","volume":" ","pages":"8"},"PeriodicalIF":0.0000,"publicationDate":"2021-03-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1186/s40662-021-00231-9","citationCount":"3","resultStr":"{\"title\":\"Investigation of corneal topographic and densitometric properties of Wilson's disease patients with or without a Kayser-Fleischer ring.\",\"authors\":\"Mehmet Fuat Alakus, Mehtap Caglayan, Nazım Ekin, Hasan Oncul, Esref Arac, Umut Dag, Halit Diri\",\"doi\":\"10.1186/s40662-021-00231-9\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>To investigate the topographic measurements and densitometry of corneas in Wilson's disease (WD) patients with or without a Kayser-Fleischer ring (KF-r) compared to healthy individuals.</p><p><strong>Methods: </strong>This cross-sectional study included 20 WD patients without a KF-r (group I), 18 WD patients with a KF-r (group II), and 20 age-matched controls (group III). The Pentacam high resolution imaging system is used to determine corneal topographic measurements and densitometry.</p><p><strong>Results: </strong>Mean age for groups I, II and III was 25.40 ± 6.43 years (14-36 years), 25.38 ± 6.96 years (16-39 years), 23.60 ± 6.56 years (17-35 years), respectively (P = 0.623). There was no significant difference between the groups in terms of the anterior corneal densitometry values (P > 0.05), while the 6-10 mm and 10-12 mm mid stroma and the 2-6 mm, 6-10 mm, and 10-12 mm posterior corneal densitometry values in group II were significantly higher than those in groups I and III (for all values, P < 0.05). However, the 10-12 mm posterior corneal densitometry values in group I were also significantly higher than those in group III (P = 0.038). The central corneal thickness (CCT), thinnest corneal thickness (tCT), and corneal volume (CV) values in groups I and II were significantly lower than those in group III (for CCT values, P = 0.011 and P = 0.009; for tCT values, P = 0.010 and P = 0.005; for CV values, P = 0.043 and P = 0.029).</p><p><strong>Conclusion: </strong>In WD patients with a KF-r, corneal transparency decreased in the peripheral posterior and mid stromal corneal layers; for these patients, corneal transparency may be impaired not only in the peripheral cornea but also in the paracentral cornea.</p>\",\"PeriodicalId\":520624,\"journal\":{\"name\":\"Eye and vision (London, England)\",\"volume\":\" \",\"pages\":\"8\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-03-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1186/s40662-021-00231-9\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Eye and vision (London, England)\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1186/s40662-021-00231-9\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Eye and vision (London, England)","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s40662-021-00231-9","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Investigation of corneal topographic and densitometric properties of Wilson's disease patients with or without a Kayser-Fleischer ring.
Background: To investigate the topographic measurements and densitometry of corneas in Wilson's disease (WD) patients with or without a Kayser-Fleischer ring (KF-r) compared to healthy individuals.
Methods: This cross-sectional study included 20 WD patients without a KF-r (group I), 18 WD patients with a KF-r (group II), and 20 age-matched controls (group III). The Pentacam high resolution imaging system is used to determine corneal topographic measurements and densitometry.
Results: Mean age for groups I, II and III was 25.40 ± 6.43 years (14-36 years), 25.38 ± 6.96 years (16-39 years), 23.60 ± 6.56 years (17-35 years), respectively (P = 0.623). There was no significant difference between the groups in terms of the anterior corneal densitometry values (P > 0.05), while the 6-10 mm and 10-12 mm mid stroma and the 2-6 mm, 6-10 mm, and 10-12 mm posterior corneal densitometry values in group II were significantly higher than those in groups I and III (for all values, P < 0.05). However, the 10-12 mm posterior corneal densitometry values in group I were also significantly higher than those in group III (P = 0.038). The central corneal thickness (CCT), thinnest corneal thickness (tCT), and corneal volume (CV) values in groups I and II were significantly lower than those in group III (for CCT values, P = 0.011 and P = 0.009; for tCT values, P = 0.010 and P = 0.005; for CV values, P = 0.043 and P = 0.029).
Conclusion: In WD patients with a KF-r, corneal transparency decreased in the peripheral posterior and mid stromal corneal layers; for these patients, corneal transparency may be impaired not only in the peripheral cornea but also in the paracentral cornea.