fMEG信号的时频和相干分析。

X Wu, Y Chan, H Preissl, H Eswaran, J Wilson, P Murphy, C L Lowery
{"title":"fMEG信号的时频和相干分析。","authors":"X Wu,&nbsp;Y Chan,&nbsp;H Preissl,&nbsp;H Eswaran,&nbsp;J Wilson,&nbsp;P Murphy,&nbsp;C L Lowery","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Fetal magnetoencephalographic (fMEG) measurements are performed with interference from the fetal and maternal magnetocardiogram (MCG). Fetal movement, fetal breathing, fetal eye blinks or eye rollings and maternal muscle-contraction may generate detectable signals. These factors can be called \"interventions,\" which can be manifested in space and/or time. They make the fMEG signals nonstationary. By examining temporal relationship of the multi-channel records, we are able to find the spatial signature of these \"interventions.\" The aim of this study is to examine nonstationarity in single channel and nonhomogeniety in multiple channels of the fMEG data. Preliminary results are reported here, and may be used in further studies, leading toward intervention identification, and ultimately fetal state determination.</p>","PeriodicalId":83814,"journal":{"name":"Neurology & clinical neurophysiology : NCN","volume":"2004 ","pages":"11"},"PeriodicalIF":0.0000,"publicationDate":"2004-11-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Time-frequency and coherence analysis of fMEG signals.\",\"authors\":\"X Wu,&nbsp;Y Chan,&nbsp;H Preissl,&nbsp;H Eswaran,&nbsp;J Wilson,&nbsp;P Murphy,&nbsp;C L Lowery\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Fetal magnetoencephalographic (fMEG) measurements are performed with interference from the fetal and maternal magnetocardiogram (MCG). Fetal movement, fetal breathing, fetal eye blinks or eye rollings and maternal muscle-contraction may generate detectable signals. These factors can be called \\\"interventions,\\\" which can be manifested in space and/or time. They make the fMEG signals nonstationary. By examining temporal relationship of the multi-channel records, we are able to find the spatial signature of these \\\"interventions.\\\" The aim of this study is to examine nonstationarity in single channel and nonhomogeniety in multiple channels of the fMEG data. Preliminary results are reported here, and may be used in further studies, leading toward intervention identification, and ultimately fetal state determination.</p>\",\"PeriodicalId\":83814,\"journal\":{\"name\":\"Neurology & clinical neurophysiology : NCN\",\"volume\":\"2004 \",\"pages\":\"11\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2004-11-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Neurology & clinical neurophysiology : NCN\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Neurology & clinical neurophysiology : NCN","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

胎儿脑磁图(fMEG)测量是在胎儿和母体心磁图(MCG)的干扰下进行的。胎儿运动、胎儿呼吸、胎儿眨眼或翻白眼以及母体肌肉收缩都可能产生可检测的信号。这些因素可以被称为“干预”,可以在空间和/或时间上表现出来。它们使fMEG信号变得不稳定。通过检查多通道记录的时间关系,我们能够找到这些“干预”的空间特征。本研究的目的是检验fMEG数据的单通道非平稳性和多通道非均匀性。这里报告了初步结果,并可能用于进一步的研究,导致干预鉴定,并最终确定胎儿状态。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Time-frequency and coherence analysis of fMEG signals.

Fetal magnetoencephalographic (fMEG) measurements are performed with interference from the fetal and maternal magnetocardiogram (MCG). Fetal movement, fetal breathing, fetal eye blinks or eye rollings and maternal muscle-contraction may generate detectable signals. These factors can be called "interventions," which can be manifested in space and/or time. They make the fMEG signals nonstationary. By examining temporal relationship of the multi-channel records, we are able to find the spatial signature of these "interventions." The aim of this study is to examine nonstationarity in single channel and nonhomogeniety in multiple channels of the fMEG data. Preliminary results are reported here, and may be used in further studies, leading toward intervention identification, and ultimately fetal state determination.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信