E Gray, P Rigsby, M-E Behr-Gross
{"title":"建立测定用低分子质量肝素的合作研究——欧洲药典生物参比制剂。","authors":"E Gray,&nbsp;P Rigsby,&nbsp;M-E Behr-Gross","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Thirty laboratories participated in a collaborative study to calibrate replacements for the 1st International Standard for Low Molecular Weight Heparin and the European Pharmacopoeia Low-molecular-mass heparin for assay Biological Reference Preparation. Two freeze-dried materials and one liquid preparation were included in the study. All three samples gave excellent intra- and inter-laboratory variations (majority of mean % geometric coefficient of variation < 10 %) when assayed against the 1st International Standard by both anti-Xa and anti-IIa assays. There were no major differences found between potency estimates using all methods and that obtained using European Pharmacopoeia method only. Overall, this study showed that the differences between the candidates are marginal. Based on the results of the study Sample B, 01/608 was established as the 2nd International Standard for Low Molecular Weight Heparin. Sample A, 01/592 and sample C, the liquid preparation, were established as replacements for the European Pharmacopoeia 'Low-molecular-mass heparin for assay' Biological Reference Preparation.</p>","PeriodicalId":86996,"journal":{"name":"Pharmeuropa bio","volume":"2004 1","pages":"59-76"},"PeriodicalIF":0.0000,"publicationDate":"2004-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Collaborative study to establish the Low-molecular-mass heparin for assay--European Pharmacopoeia Biological Reference Preparation.\",\"authors\":\"E Gray,&nbsp;P Rigsby,&nbsp;M-E Behr-Gross\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Thirty laboratories participated in a collaborative study to calibrate replacements for the 1st International Standard for Low Molecular Weight Heparin and the European Pharmacopoeia Low-molecular-mass heparin for assay Biological Reference Preparation. Two freeze-dried materials and one liquid preparation were included in the study. All three samples gave excellent intra- and inter-laboratory variations (majority of mean % geometric coefficient of variation < 10 %) when assayed against the 1st International Standard by both anti-Xa and anti-IIa assays. There were no major differences found between potency estimates using all methods and that obtained using European Pharmacopoeia method only. Overall, this study showed that the differences between the candidates are marginal. Based on the results of the study Sample B, 01/608 was established as the 2nd International Standard for Low Molecular Weight Heparin. Sample A, 01/592 and sample C, the liquid preparation, were established as replacements for the European Pharmacopoeia 'Low-molecular-mass heparin for assay' Biological Reference Preparation.</p>\",\"PeriodicalId\":86996,\"journal\":{\"name\":\"Pharmeuropa bio\",\"volume\":\"2004 1\",\"pages\":\"59-76\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2004-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Pharmeuropa bio\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Pharmeuropa bio","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

30个实验室参与了一项合作研究,以校准用于测定生物参比制剂的第一个低分子量肝素国际标准和欧洲药典低分子质量肝素的替代品。研究中包括两种冻干材料和一种液体制剂。当用抗xa和抗iia检测方法对照国际标准1进行检测时,所有三个样品在实验室内和实验室间都有很好的变化(大多数平均百分比几何变异系数< 10%)。使用所有方法的效价估计值与仅使用欧洲药典方法获得的效价估计值之间没有发现重大差异。总的来说,这项研究表明,候选人之间的差异是微乎其微的。根据研究样品B的结果,建立01/608作为低分子量肝素第二国际标准。样品A(01/592)和样品C(液体制剂)被确定为欧洲药典“低分子质量肝素测定用”生物参比制剂的替代品。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Collaborative study to establish the Low-molecular-mass heparin for assay--European Pharmacopoeia Biological Reference Preparation.

Thirty laboratories participated in a collaborative study to calibrate replacements for the 1st International Standard for Low Molecular Weight Heparin and the European Pharmacopoeia Low-molecular-mass heparin for assay Biological Reference Preparation. Two freeze-dried materials and one liquid preparation were included in the study. All three samples gave excellent intra- and inter-laboratory variations (majority of mean % geometric coefficient of variation < 10 %) when assayed against the 1st International Standard by both anti-Xa and anti-IIa assays. There were no major differences found between potency estimates using all methods and that obtained using European Pharmacopoeia method only. Overall, this study showed that the differences between the candidates are marginal. Based on the results of the study Sample B, 01/608 was established as the 2nd International Standard for Low Molecular Weight Heparin. Sample A, 01/592 and sample C, the liquid preparation, were established as replacements for the European Pharmacopoeia 'Low-molecular-mass heparin for assay' Biological Reference Preparation.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信