H E Horng, S H Liao, S J Hsu, H C Yang, J Y Wu, C C Chen, C H Wu, C C Wu
{"title":"主动补偿磁屏蔽环境下动物的心脏磁图。","authors":"H E Horng, S H Liao, S J Hsu, H C Yang, J Y Wu, C C Chen, C H Wu, C C Wu","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>A high-Tc 1st-order electronic superconducting quantum interference device (SQUID) gradiometer system is constructed to study the magnetocardiogram (MCG) of rabbits in a moderately magnetically shielded environment with active compensation. In the noisy hospital environment, the noise cannot be completely reduced with the 1st-order gradiometer, therefore, a reference SQUID with active compensation was used to further reduce the noise level leaking into the room. The MCG system was equipped with a x-y translation bed. We used a low-pass filter with the cut off frequency at 44 Hz, a high-pass filter with the cut off frequency at 0.1 Hz and the 60 Hz notch filter to reduce the power line interference. The noise level of the 1st order gradiometer MCG system in this moderately magnetically shielded room was about 1 pT/square root of Hz1/2 at 1 Hz. The MCG of a normal rabbits was measured with this system and a MCG contour map and a current density distribution was constructed.</p>","PeriodicalId":83814,"journal":{"name":"Neurology & clinical neurophysiology : NCN","volume":"2004 ","pages":"84"},"PeriodicalIF":0.0000,"publicationDate":"2004-11-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Magnetocardiography of animals in magnetically shielded environment with active compensation.\",\"authors\":\"H E Horng, S H Liao, S J Hsu, H C Yang, J Y Wu, C C Chen, C H Wu, C C Wu\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>A high-Tc 1st-order electronic superconducting quantum interference device (SQUID) gradiometer system is constructed to study the magnetocardiogram (MCG) of rabbits in a moderately magnetically shielded environment with active compensation. In the noisy hospital environment, the noise cannot be completely reduced with the 1st-order gradiometer, therefore, a reference SQUID with active compensation was used to further reduce the noise level leaking into the room. The MCG system was equipped with a x-y translation bed. We used a low-pass filter with the cut off frequency at 44 Hz, a high-pass filter with the cut off frequency at 0.1 Hz and the 60 Hz notch filter to reduce the power line interference. The noise level of the 1st order gradiometer MCG system in this moderately magnetically shielded room was about 1 pT/square root of Hz1/2 at 1 Hz. The MCG of a normal rabbits was measured with this system and a MCG contour map and a current density distribution was constructed.</p>\",\"PeriodicalId\":83814,\"journal\":{\"name\":\"Neurology & clinical neurophysiology : NCN\",\"volume\":\"2004 \",\"pages\":\"84\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2004-11-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Neurology & clinical neurophysiology : NCN\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Neurology & clinical neurophysiology : NCN","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Magnetocardiography of animals in magnetically shielded environment with active compensation.
A high-Tc 1st-order electronic superconducting quantum interference device (SQUID) gradiometer system is constructed to study the magnetocardiogram (MCG) of rabbits in a moderately magnetically shielded environment with active compensation. In the noisy hospital environment, the noise cannot be completely reduced with the 1st-order gradiometer, therefore, a reference SQUID with active compensation was used to further reduce the noise level leaking into the room. The MCG system was equipped with a x-y translation bed. We used a low-pass filter with the cut off frequency at 44 Hz, a high-pass filter with the cut off frequency at 0.1 Hz and the 60 Hz notch filter to reduce the power line interference. The noise level of the 1st order gradiometer MCG system in this moderately magnetically shielded room was about 1 pT/square root of Hz1/2 at 1 Hz. The MCG of a normal rabbits was measured with this system and a MCG contour map and a current density distribution was constructed.