用气体体积计评价三种可包装复合树脂的聚合收缩。

Q2 Dentistry
Ricardo Amore, Clóvis Pagani, Michel Nicolau Youssef, Camillo Anauate Netto, Hugo Roberto Lewgoy
{"title":"用气体体积计评价三种可包装复合树脂的聚合收缩。","authors":"Ricardo Amore,&nbsp;Clóvis Pagani,&nbsp;Michel Nicolau Youssef,&nbsp;Camillo Anauate Netto,&nbsp;Hugo Roberto Lewgoy","doi":"10.1590/s1517-74912003000300013","DOIUrl":null,"url":null,"abstract":"<p><p>Modern restorative dentistry has been playing an outstanding role lately since composite resins, allied to adhesive systems, have been widely applied on anterior and posterior teeth restorations. The evolution of composite resins has mostly been verified due to the improvement of their aesthetic behavior and the increase in their compressive and abrasive strengths. In spite of these developments, the polymerization shrinkage inherent to the material has been a major deficiency that, so far, has been impossible to avoid. Using a gas pycnometry, this research investigated the polymerization shrinkage of three packable composite resins: Filtek P60 (3M), Prodigy Condensable (Kerr), and SureFil (Dentsply/Caulk), varying the distance from the light source to the surface of the resins (2 mm or 10 mm). The pycnometer Accupyc 1330 (Micromeritics, USA) precisely records helium displacement, allowing fast and reliable measurements of the volume of composite resin immediately before and after polymerization, without interference of temperature or humidity. Results were not found to be statistically different for the three tested resins, either for 2 mm or 10 mm-distance from the light source to the composite surface.</p>","PeriodicalId":35295,"journal":{"name":"Pesquisa odontologica brasileira = Brazilian oral research","volume":"17 3","pages":"273-7"},"PeriodicalIF":0.0000,"publicationDate":"2003-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1590/s1517-74912003000300013","citationCount":"13","resultStr":"{\"title\":\"Polymerization shrinkage evaluation of three packable composite resins using a gas pycnometer.\",\"authors\":\"Ricardo Amore,&nbsp;Clóvis Pagani,&nbsp;Michel Nicolau Youssef,&nbsp;Camillo Anauate Netto,&nbsp;Hugo Roberto Lewgoy\",\"doi\":\"10.1590/s1517-74912003000300013\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Modern restorative dentistry has been playing an outstanding role lately since composite resins, allied to adhesive systems, have been widely applied on anterior and posterior teeth restorations. The evolution of composite resins has mostly been verified due to the improvement of their aesthetic behavior and the increase in their compressive and abrasive strengths. In spite of these developments, the polymerization shrinkage inherent to the material has been a major deficiency that, so far, has been impossible to avoid. Using a gas pycnometry, this research investigated the polymerization shrinkage of three packable composite resins: Filtek P60 (3M), Prodigy Condensable (Kerr), and SureFil (Dentsply/Caulk), varying the distance from the light source to the surface of the resins (2 mm or 10 mm). The pycnometer Accupyc 1330 (Micromeritics, USA) precisely records helium displacement, allowing fast and reliable measurements of the volume of composite resin immediately before and after polymerization, without interference of temperature or humidity. Results were not found to be statistically different for the three tested resins, either for 2 mm or 10 mm-distance from the light source to the composite surface.</p>\",\"PeriodicalId\":35295,\"journal\":{\"name\":\"Pesquisa odontologica brasileira = Brazilian oral research\",\"volume\":\"17 3\",\"pages\":\"273-7\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2003-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1590/s1517-74912003000300013\",\"citationCount\":\"13\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Pesquisa odontologica brasileira = Brazilian oral research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1590/s1517-74912003000300013\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2003/12/16 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"Dentistry\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Pesquisa odontologica brasileira = Brazilian oral research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1590/s1517-74912003000300013","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2003/12/16 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"Dentistry","Score":null,"Total":0}
引用次数: 13

摘要

近年来,复合树脂在牙前、后牙修复中得到了广泛的应用。复合树脂的发展主要是由于其美学性能的改善和抗压强度和磨料强度的增加而得到证实。尽管有了这些发展,材料固有的聚合收缩一直是一个主要的缺陷,到目前为止,是无法避免的。本研究使用气体体积测量法,研究了三种可包装复合树脂:Filtek P60 (3M)、Prodigy condensed (Kerr)和SureFil (Dentsply/Caulk)的聚合收缩率,改变了从光源到树脂表面的距离(2mm或10mm)。Accupyc 1330体积计(Micromeritics, USA)精确记录氦气位移,可以在聚合前后立即快速可靠地测量复合树脂的体积,而不受温度或湿度的干扰。从光源到复合材料表面的距离为2 mm或10 mm,三种测试树脂的结果没有统计学差异。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Polymerization shrinkage evaluation of three packable composite resins using a gas pycnometer.

Modern restorative dentistry has been playing an outstanding role lately since composite resins, allied to adhesive systems, have been widely applied on anterior and posterior teeth restorations. The evolution of composite resins has mostly been verified due to the improvement of their aesthetic behavior and the increase in their compressive and abrasive strengths. In spite of these developments, the polymerization shrinkage inherent to the material has been a major deficiency that, so far, has been impossible to avoid. Using a gas pycnometry, this research investigated the polymerization shrinkage of three packable composite resins: Filtek P60 (3M), Prodigy Condensable (Kerr), and SureFil (Dentsply/Caulk), varying the distance from the light source to the surface of the resins (2 mm or 10 mm). The pycnometer Accupyc 1330 (Micromeritics, USA) precisely records helium displacement, allowing fast and reliable measurements of the volume of composite resin immediately before and after polymerization, without interference of temperature or humidity. Results were not found to be statistically different for the three tested resins, either for 2 mm or 10 mm-distance from the light source to the composite surface.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
3.80
自引率
0.00%
发文量
0
期刊介绍: Pesquisa Odontológica Brasileira is a new quarterly published journal (January-March, April-June, July-September, October-December), with an annual supplement (Anais da Reunião de Pesquisa Odontológica da SBPqO), by the Sociedade Brasileira de Pesquisa Odontológica [Brazilian Society of Odontological Research] and University of São Paulo. It replaces Revista de Odontologia da Universidade de São Paulo (ISSN 0103-0663).
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信