激光诱导牙本质温度变化。

O R Keller, F E Weber, K W Grätz, M M Baltensperger, G K Eyrich
{"title":"激光诱导牙本质温度变化。","authors":"O R Keller,&nbsp;F E Weber,&nbsp;K W Grätz,&nbsp;M M Baltensperger,&nbsp;G K Eyrich","doi":"10.1089/104454703322650194","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>The purpose of this work is to study the temperature rise and potential thermal damage caused during ablation of human dentine using a super pulsed carbon dioxide laser of 9.6-microm wavelength, equipped with a water-cooling spray and scanner system.</p><p><strong>Background data: </strong>There have been no reports on thermal effects of super pulsed CO2 laser of 9.6 microm wavelength on human dentine recently.</p><p><strong>Materials and methods: </strong>Two different types of samples were investigated to yield data most consistent with a typical clinical situation. Human dentine slices and crown segments were studied at a drilling depth of 1.0 +/- 0.1 mm and 2.5 +/- 0.5 mm, respectively. A control group treated with a conventional hand piece was compared to four laser groups with settings varying from 2 to 8 W.</p><p><strong>Results: </strong>In the laser group demonstrating the highest elevation in temperature of the four studied, dentine slices lased at 2 W for 15 sec showed a mean temperature rise of less than 1.68 degrees C at an ablation rate of 0.86 +/- 0.08 mm. Conventional drilling with a comparable ablation rate of 0.76 +/- 0.59 mm resulted in a mean rise of 2.87 degrees C. The laser groups of crown segments revealed a constant decrease in temperature. SEM observations were lacking the typical morphological changes seen in earlier studies, specifically extensive melting, charring or cracking.</p><p><strong>Conclusion: </strong>A maximum rise of mean temperature to 1.68 degrees C in closest vicinity to the pulpal chamber and the morphological unaltered dentine surfaces demonstrate the safe and tissue preserving character of the superpulsed 9.6 microm CO2 laser. The laser caused an even lower temperature rise than conventional drilling. Moreover, the laser showed acceptable efficacy with ablation rates that did not significantly differ from the conventional dental drill.</p>","PeriodicalId":79503,"journal":{"name":"Journal of clinical laser medicine & surgery","volume":"21 6","pages":"375-81"},"PeriodicalIF":0.0000,"publicationDate":"2003-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1089/104454703322650194","citationCount":"7","resultStr":"{\"title\":\"Laser-induced temperature changes in dentine.\",\"authors\":\"O R Keller,&nbsp;F E Weber,&nbsp;K W Grätz,&nbsp;M M Baltensperger,&nbsp;G K Eyrich\",\"doi\":\"10.1089/104454703322650194\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objective: </strong>The purpose of this work is to study the temperature rise and potential thermal damage caused during ablation of human dentine using a super pulsed carbon dioxide laser of 9.6-microm wavelength, equipped with a water-cooling spray and scanner system.</p><p><strong>Background data: </strong>There have been no reports on thermal effects of super pulsed CO2 laser of 9.6 microm wavelength on human dentine recently.</p><p><strong>Materials and methods: </strong>Two different types of samples were investigated to yield data most consistent with a typical clinical situation. Human dentine slices and crown segments were studied at a drilling depth of 1.0 +/- 0.1 mm and 2.5 +/- 0.5 mm, respectively. A control group treated with a conventional hand piece was compared to four laser groups with settings varying from 2 to 8 W.</p><p><strong>Results: </strong>In the laser group demonstrating the highest elevation in temperature of the four studied, dentine slices lased at 2 W for 15 sec showed a mean temperature rise of less than 1.68 degrees C at an ablation rate of 0.86 +/- 0.08 mm. Conventional drilling with a comparable ablation rate of 0.76 +/- 0.59 mm resulted in a mean rise of 2.87 degrees C. The laser groups of crown segments revealed a constant decrease in temperature. SEM observations were lacking the typical morphological changes seen in earlier studies, specifically extensive melting, charring or cracking.</p><p><strong>Conclusion: </strong>A maximum rise of mean temperature to 1.68 degrees C in closest vicinity to the pulpal chamber and the morphological unaltered dentine surfaces demonstrate the safe and tissue preserving character of the superpulsed 9.6 microm CO2 laser. The laser caused an even lower temperature rise than conventional drilling. Moreover, the laser showed acceptable efficacy with ablation rates that did not significantly differ from the conventional dental drill.</p>\",\"PeriodicalId\":79503,\"journal\":{\"name\":\"Journal of clinical laser medicine & surgery\",\"volume\":\"21 6\",\"pages\":\"375-81\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2003-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1089/104454703322650194\",\"citationCount\":\"7\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of clinical laser medicine & surgery\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1089/104454703322650194\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of clinical laser medicine & surgery","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1089/104454703322650194","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 7

摘要

目的:研究9.6微米波长超脉冲二氧化碳激光在水冷喷涂和扫描系统下消融人牙本质过程中的温升和潜在热损伤。背景资料:9.6微米波长超脉冲CO2激光对人牙本质的热效应,目前尚未见报道。材料和方法:研究了两种不同类型的样本,以获得最符合典型临床情况的数据。钻孔深度分别为1.0 +/- 0.1 mm和2.5 +/- 0.5 mm,研究人类牙本质切片和牙冠段。对照组用传统的手片治疗,与四组设置从2到8 W不等的激光进行比较。结果:在四种研究中,激光组的温度升高最高,在2 W激光照射15秒的情况下,牙本质切片的平均温升小于1.68℃,烧蚀率为0.86±0.08 mm。传统钻孔的烧蚀率为0.76 +/- 0.59 mm,平均升温2.87℃,冠段激光组温度持续下降。扫描电镜观察缺乏早期研究中看到的典型形态变化,特别是广泛的熔化,炭化或开裂。结论:超脉冲9.6微米CO2激光在牙髓腔附近的平均温度最高可达1.68℃,牙本质表面形态未发生改变,具有安全、保存组织的特点。激光造成的温升甚至比传统钻孔更低。此外,激光显示出可接受的疗效,消融率与传统牙钻没有显着差异。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Laser-induced temperature changes in dentine.

Objective: The purpose of this work is to study the temperature rise and potential thermal damage caused during ablation of human dentine using a super pulsed carbon dioxide laser of 9.6-microm wavelength, equipped with a water-cooling spray and scanner system.

Background data: There have been no reports on thermal effects of super pulsed CO2 laser of 9.6 microm wavelength on human dentine recently.

Materials and methods: Two different types of samples were investigated to yield data most consistent with a typical clinical situation. Human dentine slices and crown segments were studied at a drilling depth of 1.0 +/- 0.1 mm and 2.5 +/- 0.5 mm, respectively. A control group treated with a conventional hand piece was compared to four laser groups with settings varying from 2 to 8 W.

Results: In the laser group demonstrating the highest elevation in temperature of the four studied, dentine slices lased at 2 W for 15 sec showed a mean temperature rise of less than 1.68 degrees C at an ablation rate of 0.86 +/- 0.08 mm. Conventional drilling with a comparable ablation rate of 0.76 +/- 0.59 mm resulted in a mean rise of 2.87 degrees C. The laser groups of crown segments revealed a constant decrease in temperature. SEM observations were lacking the typical morphological changes seen in earlier studies, specifically extensive melting, charring or cracking.

Conclusion: A maximum rise of mean temperature to 1.68 degrees C in closest vicinity to the pulpal chamber and the morphological unaltered dentine surfaces demonstrate the safe and tissue preserving character of the superpulsed 9.6 microm CO2 laser. The laser caused an even lower temperature rise than conventional drilling. Moreover, the laser showed acceptable efficacy with ablation rates that did not significantly differ from the conventional dental drill.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信