飞机发动机冷启动微粒的取样分析及静电个人微粒取样器的演示。

Alfredo Armendariz, David Leith, Maryanne Boundy, Randall Goodman, Les Smith, Gary Carlton
{"title":"飞机发动机冷启动微粒的取样分析及静电个人微粒取样器的演示。","authors":"Alfredo Armendariz,&nbsp;David Leith,&nbsp;Maryanne Boundy,&nbsp;Randall Goodman,&nbsp;Les Smith,&nbsp;Gary Carlton","doi":"10.1202/512.1","DOIUrl":null,"url":null,"abstract":"<p><p>Aircraft engines emit an aerosol plume during startup in extremely cold weather that can drift into areas occupied by flightline ground crews. This study tested a personal sampler used to assess exposure to particles in the plume under challenging field conditions. Area and personal samples were taken at two U.S. Air Force (USAF) flightlines during the winter months. Small tube-and-wire electrostatic precipitators (ESPs) were mounted on a stationary stand positioned behind the engines to sample the exhaust. Other ESPs were worn by ground crews to sample breathing zone concentrations. In addition, an aerodynamic particle sizer 3320 (APS) was used to determine the size distribution of the particles. Samples collected with the ESP were solvent extracted and analyzed with gas chromatography-mass spectrometry. Results indicated that the plume consisted of up to 75 mg/m(3) of unburned jet fuel particles. The APS showed that nearly the entire particle mass was respirable, because the plumes had mass median diameters less than 2 micro m. These tests demonstrated that the ESP could be used at cold USAF flightlines to perform exposure assessments to the cold start particles.</p>","PeriodicalId":83618,"journal":{"name":"AIHA journal : a journal for the science of occupational and environmental health and safety","volume":"64 6","pages":"777-84"},"PeriodicalIF":0.0000,"publicationDate":"2003-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Sampling and analysis of aircraft engine cold start particles and demonstration of an electrostatic personal particle sampler.\",\"authors\":\"Alfredo Armendariz,&nbsp;David Leith,&nbsp;Maryanne Boundy,&nbsp;Randall Goodman,&nbsp;Les Smith,&nbsp;Gary Carlton\",\"doi\":\"10.1202/512.1\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Aircraft engines emit an aerosol plume during startup in extremely cold weather that can drift into areas occupied by flightline ground crews. This study tested a personal sampler used to assess exposure to particles in the plume under challenging field conditions. Area and personal samples were taken at two U.S. Air Force (USAF) flightlines during the winter months. Small tube-and-wire electrostatic precipitators (ESPs) were mounted on a stationary stand positioned behind the engines to sample the exhaust. Other ESPs were worn by ground crews to sample breathing zone concentrations. In addition, an aerodynamic particle sizer 3320 (APS) was used to determine the size distribution of the particles. Samples collected with the ESP were solvent extracted and analyzed with gas chromatography-mass spectrometry. Results indicated that the plume consisted of up to 75 mg/m(3) of unburned jet fuel particles. The APS showed that nearly the entire particle mass was respirable, because the plumes had mass median diameters less than 2 micro m. These tests demonstrated that the ESP could be used at cold USAF flightlines to perform exposure assessments to the cold start particles.</p>\",\"PeriodicalId\":83618,\"journal\":{\"name\":\"AIHA journal : a journal for the science of occupational and environmental health and safety\",\"volume\":\"64 6\",\"pages\":\"777-84\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2003-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"AIHA journal : a journal for the science of occupational and environmental health and safety\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1202/512.1\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"AIHA journal : a journal for the science of occupational and environmental health and safety","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1202/512.1","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

在极端寒冷的天气下,飞机发动机在启动过程中会释放出一种气溶胶羽状物,这种气溶胶会飘到航线地勤人员所在的区域。这项研究测试了一个个人采样器,用于评估在具有挑战性的现场条件下暴露于羽流中的颗粒。在冬季的几个月里,在美国空军(USAF)的两条航线上采集了区域和个人样本。小型管线式静电除尘器(esp)安装在发动机后面的固定支架上,对尾气进行取样。其他esp由地勤人员佩戴,以检测呼吸区浓度。此外,采用气动粒度仪3320 (APS)测定了颗粒的粒径分布。ESP采集的样品经溶剂萃取,气相色谱-质谱联用分析。结果表明,羽流由高达75 mg/m(3)的未燃烧喷气燃料颗粒组成。APS表明,由于羽流的质量中值直径小于2微米,几乎整个颗粒质量都是可吸入的。这些测试表明,ESP可以用于寒冷的美国空军航线,对冷启动颗粒进行暴露评估。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Sampling and analysis of aircraft engine cold start particles and demonstration of an electrostatic personal particle sampler.

Aircraft engines emit an aerosol plume during startup in extremely cold weather that can drift into areas occupied by flightline ground crews. This study tested a personal sampler used to assess exposure to particles in the plume under challenging field conditions. Area and personal samples were taken at two U.S. Air Force (USAF) flightlines during the winter months. Small tube-and-wire electrostatic precipitators (ESPs) were mounted on a stationary stand positioned behind the engines to sample the exhaust. Other ESPs were worn by ground crews to sample breathing zone concentrations. In addition, an aerodynamic particle sizer 3320 (APS) was used to determine the size distribution of the particles. Samples collected with the ESP were solvent extracted and analyzed with gas chromatography-mass spectrometry. Results indicated that the plume consisted of up to 75 mg/m(3) of unburned jet fuel particles. The APS showed that nearly the entire particle mass was respirable, because the plumes had mass median diameters less than 2 micro m. These tests demonstrated that the ESP could be used at cold USAF flightlines to perform exposure assessments to the cold start particles.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信