{"title":"工作场所暴露于人工弧焊碳钢产生的亚微米颗粒质量和数量浓度。","authors":"Dale Stephenson,&nbsp;Gauri Seshadri,&nbsp;John M Veranth","doi":"10.1202/394.1","DOIUrl":null,"url":null,"abstract":"<p><p>Particle emissions from manual shielded metal arc welding of carbon steel were sampled in a typical industrial maintenance and metal fabrication workplace environment. Particle number measurements over the size range from 14 nm to 10 microm using a scanning mobility particle sizer and an optical particle counter showed that welding produced an approximately lognormal particle mode with a 120 nm count median and a geometric standard deviation of 2.07. This study produced welding particle number concentrations on the order of 2 x 10(5)/cm(3) in the building air 8.5 m away from the welding. Workplace exposure samples were below the current 8-hour American Conference of Governmental Industrial Hygienists mass concentration threshold limit value of 5 mg/m(3). Submicron particles comprised 80% of the total aerosol mass collected by a cascade impactor during welding. The concentration of larger particles was indistinguishable from indoor background. Microscopy showed that the welding emissions are dominated by clusters formed from <0.1 microm primary spheres. These data on the particles resulting from aerosol transformation by natural dilution inside an industrial building can be compared with laboratory-scale studies of welding particulate. The particle number characteristics observed in this study are significant because toxicological hypotheses suggest that number or surface area may be a better metric than mass when evaluating the health effects of fine particles.</p>","PeriodicalId":83618,"journal":{"name":"AIHA journal : a journal for the science of occupational and environmental health and safety","volume":"64 4","pages":"516-21"},"PeriodicalIF":0.0000,"publicationDate":"2003-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Workplace exposure to submicron particle mass and number concentrations from manual arc welding of carbon steel.\",\"authors\":\"Dale Stephenson,&nbsp;Gauri Seshadri,&nbsp;John M Veranth\",\"doi\":\"10.1202/394.1\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Particle emissions from manual shielded metal arc welding of carbon steel were sampled in a typical industrial maintenance and metal fabrication workplace environment. Particle number measurements over the size range from 14 nm to 10 microm using a scanning mobility particle sizer and an optical particle counter showed that welding produced an approximately lognormal particle mode with a 120 nm count median and a geometric standard deviation of 2.07. This study produced welding particle number concentrations on the order of 2 x 10(5)/cm(3) in the building air 8.5 m away from the welding. Workplace exposure samples were below the current 8-hour American Conference of Governmental Industrial Hygienists mass concentration threshold limit value of 5 mg/m(3). Submicron particles comprised 80% of the total aerosol mass collected by a cascade impactor during welding. The concentration of larger particles was indistinguishable from indoor background. Microscopy showed that the welding emissions are dominated by clusters formed from <0.1 microm primary spheres. These data on the particles resulting from aerosol transformation by natural dilution inside an industrial building can be compared with laboratory-scale studies of welding particulate. The particle number characteristics observed in this study are significant because toxicological hypotheses suggest that number or surface area may be a better metric than mass when evaluating the health effects of fine particles.</p>\",\"PeriodicalId\":83618,\"journal\":{\"name\":\"AIHA journal : a journal for the science of occupational and environmental health and safety\",\"volume\":\"64 4\",\"pages\":\"516-21\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2003-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"AIHA journal : a journal for the science of occupational and environmental health and safety\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1202/394.1\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"AIHA journal : a journal for the science of occupational and environmental health and safety","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1202/394.1","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

在典型的工业维修和金属加工工作环境中,对碳钢手工保护金属电弧焊的颗粒排放进行了采样。使用扫描迁移率粒度仪和光学粒子计数器在14 nm至10微米的尺寸范围内测量粒子数,结果表明,焊接产生的粒子模式近似对数正态分布,计数中位数为120 nm,几何标准偏差为2.07。本研究得出,在距离焊接点8.5 m的建筑空气中,焊接颗粒数浓度约为2 × 10(5)/cm(3)。工作场所暴露样本低于目前美国政府工业卫生学家会议的8小时质量浓度阈值5 mg/m(3)。在焊接过程中,亚微米颗粒占级联冲击器收集的总气溶胶质量的80%。较大颗粒的浓度与室内背景无法区分。显微观察表明,焊接辐射主要是由
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Workplace exposure to submicron particle mass and number concentrations from manual arc welding of carbon steel.

Particle emissions from manual shielded metal arc welding of carbon steel were sampled in a typical industrial maintenance and metal fabrication workplace environment. Particle number measurements over the size range from 14 nm to 10 microm using a scanning mobility particle sizer and an optical particle counter showed that welding produced an approximately lognormal particle mode with a 120 nm count median and a geometric standard deviation of 2.07. This study produced welding particle number concentrations on the order of 2 x 10(5)/cm(3) in the building air 8.5 m away from the welding. Workplace exposure samples were below the current 8-hour American Conference of Governmental Industrial Hygienists mass concentration threshold limit value of 5 mg/m(3). Submicron particles comprised 80% of the total aerosol mass collected by a cascade impactor during welding. The concentration of larger particles was indistinguishable from indoor background. Microscopy showed that the welding emissions are dominated by clusters formed from <0.1 microm primary spheres. These data on the particles resulting from aerosol transformation by natural dilution inside an industrial building can be compared with laboratory-scale studies of welding particulate. The particle number characteristics observed in this study are significant because toxicological hypotheses suggest that number or surface area may be a better metric than mass when evaluating the health effects of fine particles.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信