机械心脏瓣膜假体引起的空化——综述。

APMIS. Supplementum Pub Date : 2003-01-01
Peter Johansen, Brandon R Travis, Peter K Paulsen, Hans Nygaard, J Michael Hasenkam
{"title":"机械心脏瓣膜假体引起的空化——综述。","authors":"Peter Johansen,&nbsp;Brandon R Travis,&nbsp;Peter K Paulsen,&nbsp;Hans Nygaard,&nbsp;J Michael Hasenkam","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Heart valve dysfunction often necessitates surgical implantation of a mechanical heart valve (MHV). Although implantation of a MHV is a life-saving procedure, the patient still faces potentially complications such as thromboembolic events and material failure. These complications may be caused by cavitation, which can occur during valve closure. Cavitation is an erosive phenomenon that can be generated in fluids when the pressure locally drops below the vapor pressure. This paper reviews the literature on cavitation and MHVs and particular features of the valve and closing conditions that potentially increase the intensity of cavitation. Techniques for detecting cavitation will be discussed. Of these, an acoustic approach will be emphasized, since it is currently the only technique able to detect and quantify cavitation in vivo.</p>","PeriodicalId":77006,"journal":{"name":"APMIS. Supplementum","volume":" 109","pages":"108-12"},"PeriodicalIF":0.0000,"publicationDate":"2003-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Cavitation caused by mechanical heart valve prostheses--a review.\",\"authors\":\"Peter Johansen,&nbsp;Brandon R Travis,&nbsp;Peter K Paulsen,&nbsp;Hans Nygaard,&nbsp;J Michael Hasenkam\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Heart valve dysfunction often necessitates surgical implantation of a mechanical heart valve (MHV). Although implantation of a MHV is a life-saving procedure, the patient still faces potentially complications such as thromboembolic events and material failure. These complications may be caused by cavitation, which can occur during valve closure. Cavitation is an erosive phenomenon that can be generated in fluids when the pressure locally drops below the vapor pressure. This paper reviews the literature on cavitation and MHVs and particular features of the valve and closing conditions that potentially increase the intensity of cavitation. Techniques for detecting cavitation will be discussed. Of these, an acoustic approach will be emphasized, since it is currently the only technique able to detect and quantify cavitation in vivo.</p>\",\"PeriodicalId\":77006,\"journal\":{\"name\":\"APMIS. Supplementum\",\"volume\":\" 109\",\"pages\":\"108-12\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2003-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"APMIS. Supplementum\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"APMIS. Supplementum","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

心脏瓣膜功能障碍往往需要手术植入机械心脏瓣膜(MHV)。尽管植入MHV是一项挽救生命的手术,但患者仍然面临潜在的并发症,如血栓栓塞事件和材料失效。这些并发症可能是由在阀门关闭过程中发生的空化引起的。空化是一种侵蚀现象,当局部压力低于蒸汽压时,会在流体中产生。本文综述了有关气蚀和mhv的文献,以及可能增加气蚀强度的阀门的特性和关闭条件。将讨论探测空化的技术。其中,声学方法将被强调,因为它是目前唯一能够检测和量化体内空化的技术。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Cavitation caused by mechanical heart valve prostheses--a review.

Heart valve dysfunction often necessitates surgical implantation of a mechanical heart valve (MHV). Although implantation of a MHV is a life-saving procedure, the patient still faces potentially complications such as thromboembolic events and material failure. These complications may be caused by cavitation, which can occur during valve closure. Cavitation is an erosive phenomenon that can be generated in fluids when the pressure locally drops below the vapor pressure. This paper reviews the literature on cavitation and MHVs and particular features of the valve and closing conditions that potentially increase the intensity of cavitation. Techniques for detecting cavitation will be discussed. Of these, an acoustic approach will be emphasized, since it is currently the only technique able to detect and quantify cavitation in vivo.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信