Muhammad I Ibrahimy, M A Mohd Ali, Edmond Zahedi, Shinji Tsuruoka
{"title":"腹部心电图与多普勒超声检测胎儿心率的比较。","authors":"Muhammad I Ibrahimy, M A Mohd Ali, Edmond Zahedi, Shinji Tsuruoka","doi":"10.1163/156855701321138950","DOIUrl":null,"url":null,"abstract":"<p><p>A fetal monitor has been developed for the measurement of the fetal and maternal heart rates from maternal abdominal electrocardiogram during pregnancy and labor for ambulatory monitoring. Developed algorithm of the fetal monitor is based on digital filtering, adaptive thresholding. statistical properties in the time domain and differencing of local maxima and minima. Five volunteers with low risk pregnancies, between 35 to 40 weeks of gestation and no evidence of labor, were studied for the fetal heart rate detection. A Doppler ultrasound fetal monitor was used to compare the accuracy of the measurement system. Results showed an average percent rms difference (PRD) of 5.32% in comparison with the reference ultrasound method. The fetal heart rates curve remained inside a +/- 5 beats/min limit relative to the reference ultrasound method for 84.1% of the time.</p>","PeriodicalId":77139,"journal":{"name":"Frontiers of medical and biological engineering : the international journal of the Japan Society of Medical Electronics and Biological Engineering","volume":"11 4","pages":"307-22"},"PeriodicalIF":0.0000,"publicationDate":"2002-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1163/156855701321138950","citationCount":"4","resultStr":"{\"title\":\"A comparison of abdominal ECG and Doppler ultrasound for fetal heart rate detection.\",\"authors\":\"Muhammad I Ibrahimy, M A Mohd Ali, Edmond Zahedi, Shinji Tsuruoka\",\"doi\":\"10.1163/156855701321138950\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>A fetal monitor has been developed for the measurement of the fetal and maternal heart rates from maternal abdominal electrocardiogram during pregnancy and labor for ambulatory monitoring. Developed algorithm of the fetal monitor is based on digital filtering, adaptive thresholding. statistical properties in the time domain and differencing of local maxima and minima. Five volunteers with low risk pregnancies, between 35 to 40 weeks of gestation and no evidence of labor, were studied for the fetal heart rate detection. A Doppler ultrasound fetal monitor was used to compare the accuracy of the measurement system. Results showed an average percent rms difference (PRD) of 5.32% in comparison with the reference ultrasound method. The fetal heart rates curve remained inside a +/- 5 beats/min limit relative to the reference ultrasound method for 84.1% of the time.</p>\",\"PeriodicalId\":77139,\"journal\":{\"name\":\"Frontiers of medical and biological engineering : the international journal of the Japan Society of Medical Electronics and Biological Engineering\",\"volume\":\"11 4\",\"pages\":\"307-22\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2002-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1163/156855701321138950\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Frontiers of medical and biological engineering : the international journal of the Japan Society of Medical Electronics and Biological Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1163/156855701321138950\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Frontiers of medical and biological engineering : the international journal of the Japan Society of Medical Electronics and Biological Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1163/156855701321138950","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
A comparison of abdominal ECG and Doppler ultrasound for fetal heart rate detection.
A fetal monitor has been developed for the measurement of the fetal and maternal heart rates from maternal abdominal electrocardiogram during pregnancy and labor for ambulatory monitoring. Developed algorithm of the fetal monitor is based on digital filtering, adaptive thresholding. statistical properties in the time domain and differencing of local maxima and minima. Five volunteers with low risk pregnancies, between 35 to 40 weeks of gestation and no evidence of labor, were studied for the fetal heart rate detection. A Doppler ultrasound fetal monitor was used to compare the accuracy of the measurement system. Results showed an average percent rms difference (PRD) of 5.32% in comparison with the reference ultrasound method. The fetal heart rates curve remained inside a +/- 5 beats/min limit relative to the reference ultrasound method for 84.1% of the time.