{"title":"高背景水平损害了心肌肌钙蛋白I RNA检测作为心脏病学诊断工具在外周血中的应用。","authors":"P Tschentscher, C Heeschen, C Hamm, C Wagener","doi":"10.1007/s005990070027","DOIUrl":null,"url":null,"abstract":"<p><p>The detection of cardiac troponins in peripheral blood as protein markers of myocardial infarction is a new diagnostic tool in the diagnosis of cardiac disease. In order to increase the sensitivity and specificity of this diagnostic approach, a reverse transcription polymerase chain reaction assay has been developed to detect the mRNA encoding cardiac troponin I from myocardial cells hypothetically released from damaged cardiac tissue. The detection is specific for cardiac troponin I mRNA, with no amplification of homologous sequences of other troponin I isoforms, i.e., troponin I from skeletal muscle cells. However, a strong amplification signal for cardiac troponin I mRNA was detected in samples of peripheral blood from healthy human volunteers. In patients with acute myocardial infarction or angina pectoris, the cardiac troponin I mRNA levels were not increased over background levels. In conclusion, a reverse transcription polymerase chain reaction approach based on the amplification of cardiac troponin I mRNA is not feasible in the diagnosis of cardiac diseases.</p>","PeriodicalId":77180,"journal":{"name":"International journal of clinical & laboratory research","volume":"30 1","pages":"13-5"},"PeriodicalIF":0.0000,"publicationDate":"2000-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1007/s005990070027","citationCount":"2","resultStr":"{\"title\":\"High background levels compromise the use of cardiac troponin I RNA detection in peripheral blood as a diagnostic tool in cardiology.\",\"authors\":\"P Tschentscher, C Heeschen, C Hamm, C Wagener\",\"doi\":\"10.1007/s005990070027\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The detection of cardiac troponins in peripheral blood as protein markers of myocardial infarction is a new diagnostic tool in the diagnosis of cardiac disease. In order to increase the sensitivity and specificity of this diagnostic approach, a reverse transcription polymerase chain reaction assay has been developed to detect the mRNA encoding cardiac troponin I from myocardial cells hypothetically released from damaged cardiac tissue. The detection is specific for cardiac troponin I mRNA, with no amplification of homologous sequences of other troponin I isoforms, i.e., troponin I from skeletal muscle cells. However, a strong amplification signal for cardiac troponin I mRNA was detected in samples of peripheral blood from healthy human volunteers. In patients with acute myocardial infarction or angina pectoris, the cardiac troponin I mRNA levels were not increased over background levels. In conclusion, a reverse transcription polymerase chain reaction approach based on the amplification of cardiac troponin I mRNA is not feasible in the diagnosis of cardiac diseases.</p>\",\"PeriodicalId\":77180,\"journal\":{\"name\":\"International journal of clinical & laboratory research\",\"volume\":\"30 1\",\"pages\":\"13-5\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2000-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1007/s005990070027\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International journal of clinical & laboratory research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1007/s005990070027\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International journal of clinical & laboratory research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/s005990070027","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
High background levels compromise the use of cardiac troponin I RNA detection in peripheral blood as a diagnostic tool in cardiology.
The detection of cardiac troponins in peripheral blood as protein markers of myocardial infarction is a new diagnostic tool in the diagnosis of cardiac disease. In order to increase the sensitivity and specificity of this diagnostic approach, a reverse transcription polymerase chain reaction assay has been developed to detect the mRNA encoding cardiac troponin I from myocardial cells hypothetically released from damaged cardiac tissue. The detection is specific for cardiac troponin I mRNA, with no amplification of homologous sequences of other troponin I isoforms, i.e., troponin I from skeletal muscle cells. However, a strong amplification signal for cardiac troponin I mRNA was detected in samples of peripheral blood from healthy human volunteers. In patients with acute myocardial infarction or angina pectoris, the cardiac troponin I mRNA levels were not increased over background levels. In conclusion, a reverse transcription polymerase chain reaction approach based on the amplification of cardiac troponin I mRNA is not feasible in the diagnosis of cardiac diseases.