膜技术净化血液——一种有效去除低密度脂蛋白胆固醇的新方法。

J M Wójcicki, A Ciechanowska, W Strobl, S Sabalińska, D Falkenhagen
{"title":"膜技术净化血液——一种有效去除低密度脂蛋白胆固醇的新方法。","authors":"J M Wójcicki,&nbsp;A Ciechanowska,&nbsp;W Strobl,&nbsp;S Sabalińska,&nbsp;D Falkenhagen","doi":"10.1163/15685570052061982","DOIUrl":null,"url":null,"abstract":"<p><p>A membrane plasma fractionation (MPS) technique is applied in order to obtain selective removal of pathological plasma components from the extracorporeal circuit. An effective plasma fractionation procedure should be characterized by the highest possible removal of the pathological plasma components and, equally as important, the lowest unwanted protein losses caused mainly by adsorption to the membrane structure. In order to obtain a higher efficiency of the MPS procedure (high selectivity between removal of pathological plasma components and unwanted losses mainly represented by albumin) several methods such as thermofiltration, application of pulsate flow at the end of secondary filter, etc. have been developed. Clinical verification of these methods led to some improvement in MPS procedure but these results did not seem to be optimal. The main objective of this paper is to present a new two-stage membrane system utilizing a high flow recirculation circuit developed particularly, but not only, for effective removal of low-density lipoprotein cholesterol. The designed and developed system has been tested in vitro using several different plasma fractionation membranes. The results obtained indicated the importance of the membrane structure and membrane material on the efficiency of the tested plasma fractionation procedure. It was also found that it is possible to obtain negligible protein losses for some selected membrane structures applied in the assessed system. Based on preliminary results, it seems that the new two-stage membrane system proposed could be characterized by a very low range of unwanted protein losses leading to high effectiveness of the plasma fractionation procedure.</p>","PeriodicalId":77139,"journal":{"name":"Frontiers of medical and biological engineering : the international journal of the Japan Society of Medical Electronics and Biological Engineering","volume":"10 2","pages":"131-7"},"PeriodicalIF":0.0000,"publicationDate":"2000-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1163/15685570052061982","citationCount":"2","resultStr":"{\"title\":\"Blood purification by a membrane technique--a new method for the effective removal of low-density lipoprotein cholesterol.\",\"authors\":\"J M Wójcicki,&nbsp;A Ciechanowska,&nbsp;W Strobl,&nbsp;S Sabalińska,&nbsp;D Falkenhagen\",\"doi\":\"10.1163/15685570052061982\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>A membrane plasma fractionation (MPS) technique is applied in order to obtain selective removal of pathological plasma components from the extracorporeal circuit. An effective plasma fractionation procedure should be characterized by the highest possible removal of the pathological plasma components and, equally as important, the lowest unwanted protein losses caused mainly by adsorption to the membrane structure. In order to obtain a higher efficiency of the MPS procedure (high selectivity between removal of pathological plasma components and unwanted losses mainly represented by albumin) several methods such as thermofiltration, application of pulsate flow at the end of secondary filter, etc. have been developed. Clinical verification of these methods led to some improvement in MPS procedure but these results did not seem to be optimal. The main objective of this paper is to present a new two-stage membrane system utilizing a high flow recirculation circuit developed particularly, but not only, for effective removal of low-density lipoprotein cholesterol. The designed and developed system has been tested in vitro using several different plasma fractionation membranes. The results obtained indicated the importance of the membrane structure and membrane material on the efficiency of the tested plasma fractionation procedure. It was also found that it is possible to obtain negligible protein losses for some selected membrane structures applied in the assessed system. Based on preliminary results, it seems that the new two-stage membrane system proposed could be characterized by a very low range of unwanted protein losses leading to high effectiveness of the plasma fractionation procedure.</p>\",\"PeriodicalId\":77139,\"journal\":{\"name\":\"Frontiers of medical and biological engineering : the international journal of the Japan Society of Medical Electronics and Biological Engineering\",\"volume\":\"10 2\",\"pages\":\"131-7\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2000-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1163/15685570052061982\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Frontiers of medical and biological engineering : the international journal of the Japan Society of Medical Electronics and Biological Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1163/15685570052061982\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Frontiers of medical and biological engineering : the international journal of the Japan Society of Medical Electronics and Biological Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1163/15685570052061982","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

膜等离子体分离(MPS)技术的应用,以获得选择性去除病理等离子体成分从体外电路。一个有效的血浆分离程序的特点应该是尽可能去除病理血浆成分,同样重要的是,减少主要由膜结构吸附引起的不必要的蛋白质损失。为了获得更高的MPS程序效率(去除病理血浆成分和主要以白蛋白为代表的不必要损失之间的高选择性),已经开发了几种方法,如热过滤,在二级过滤末端应用脉冲流等。这些方法的临床验证导致MPS程序的一些改进,但这些结果似乎并不理想。本文的主要目的是提出一种新的两级膜系统,利用高流量循环回路,特别是,但不仅仅是,有效地去除低密度脂蛋白胆固醇。设计和开发的系统已经在体外使用几种不同的血浆分离膜进行了测试。实验结果表明,膜结构和膜材料对等离子体分离过程的效率有重要影响。还发现,在评估系统中应用的一些选定的膜结构可以获得可忽略不计的蛋白质损失。根据初步结果,似乎提出的新的两级膜系统可以具有非常低的不必要的蛋白质损失范围,从而导致血浆分离过程的高效率。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Blood purification by a membrane technique--a new method for the effective removal of low-density lipoprotein cholesterol.

A membrane plasma fractionation (MPS) technique is applied in order to obtain selective removal of pathological plasma components from the extracorporeal circuit. An effective plasma fractionation procedure should be characterized by the highest possible removal of the pathological plasma components and, equally as important, the lowest unwanted protein losses caused mainly by adsorption to the membrane structure. In order to obtain a higher efficiency of the MPS procedure (high selectivity between removal of pathological plasma components and unwanted losses mainly represented by albumin) several methods such as thermofiltration, application of pulsate flow at the end of secondary filter, etc. have been developed. Clinical verification of these methods led to some improvement in MPS procedure but these results did not seem to be optimal. The main objective of this paper is to present a new two-stage membrane system utilizing a high flow recirculation circuit developed particularly, but not only, for effective removal of low-density lipoprotein cholesterol. The designed and developed system has been tested in vitro using several different plasma fractionation membranes. The results obtained indicated the importance of the membrane structure and membrane material on the efficiency of the tested plasma fractionation procedure. It was also found that it is possible to obtain negligible protein losses for some selected membrane structures applied in the assessed system. Based on preliminary results, it seems that the new two-stage membrane system proposed could be characterized by a very low range of unwanted protein losses leading to high effectiveness of the plasma fractionation procedure.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信