{"title":"[夜间脉搏血氧仪在睡眠呼吸暂停筛查中的预测价值]。","authors":"R Nuber, J Vavrina, W Karrer","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>The monitoring of overnight oxygen saturation is widely used for sleep apnoea screening. The point of this screening has been questioned as a wide range of sensitivity has been reported in the literature. In a prospective study 70 subjects presenting with a possible sleep apnoea-hypopnoea syndrome had overnight oximetry followed by polysomnography 2 to 4 months later. Compared to polysomnography, the sensitivity of oximetry for sleep apnoea-hypopnoea was 85.2%, the specificity 77.8% and the predictive value positive 96.3%. When short, non-significant, repetitive desaturations have been declared pathologic, sensitivity increased to 91.8%. In the hands of an expert user, oximetry represents an excellent instrument for detecting patients with sleep apnoea-hypopnoea. Patients with pathological nocturnal oximetry are candidates for nCPAP treatment and therefore should undergo a sleep laboratory investigation.</p>","PeriodicalId":76532,"journal":{"name":"Schweizerische medizinische Wochenschrift. Supplementum","volume":"116 ","pages":"120S-122S"},"PeriodicalIF":0.0000,"publicationDate":"2000-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"[Predictive value of nocturnal pulse oximetry in sleep apnea screening].\",\"authors\":\"R Nuber, J Vavrina, W Karrer\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The monitoring of overnight oxygen saturation is widely used for sleep apnoea screening. The point of this screening has been questioned as a wide range of sensitivity has been reported in the literature. In a prospective study 70 subjects presenting with a possible sleep apnoea-hypopnoea syndrome had overnight oximetry followed by polysomnography 2 to 4 months later. Compared to polysomnography, the sensitivity of oximetry for sleep apnoea-hypopnoea was 85.2%, the specificity 77.8% and the predictive value positive 96.3%. When short, non-significant, repetitive desaturations have been declared pathologic, sensitivity increased to 91.8%. In the hands of an expert user, oximetry represents an excellent instrument for detecting patients with sleep apnoea-hypopnoea. Patients with pathological nocturnal oximetry are candidates for nCPAP treatment and therefore should undergo a sleep laboratory investigation.</p>\",\"PeriodicalId\":76532,\"journal\":{\"name\":\"Schweizerische medizinische Wochenschrift. Supplementum\",\"volume\":\"116 \",\"pages\":\"120S-122S\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2000-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Schweizerische medizinische Wochenschrift. Supplementum\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Schweizerische medizinische Wochenschrift. Supplementum","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
[Predictive value of nocturnal pulse oximetry in sleep apnea screening].
The monitoring of overnight oxygen saturation is widely used for sleep apnoea screening. The point of this screening has been questioned as a wide range of sensitivity has been reported in the literature. In a prospective study 70 subjects presenting with a possible sleep apnoea-hypopnoea syndrome had overnight oximetry followed by polysomnography 2 to 4 months later. Compared to polysomnography, the sensitivity of oximetry for sleep apnoea-hypopnoea was 85.2%, the specificity 77.8% and the predictive value positive 96.3%. When short, non-significant, repetitive desaturations have been declared pathologic, sensitivity increased to 91.8%. In the hands of an expert user, oximetry represents an excellent instrument for detecting patients with sleep apnoea-hypopnoea. Patients with pathological nocturnal oximetry are candidates for nCPAP treatment and therefore should undergo a sleep laboratory investigation.