{"title":"支架的腐蚀测试:一种新颖的夹具,以保持整个设备的部署形式和完成。","authors":"R Venugopalan","doi":"10.1002/(sici)1097-4636(1999)48:6<829::aid-jbm10>3.0.co;2-#","DOIUrl":null,"url":null,"abstract":"<p><p>Stainless steel and nickel-titanium alloy stents for cardiac, biliary, and prostatic clinical applications may be susceptible to loss of mechanical integrity/failure due to their small size and unique geometry. Because their corrosion behavior is a critical aspect of their biocompatibility, it is necessary to test such devices for corrosion behavior using a final deployed form and finish condition. Welding wire leads or holding with metallic clips can result in surface variability or damage to the stents. A novel fixture to hold stents for corrosion testing was designed and evaluated in this study. This fixture design minimally influenced the properties of stents, and also facilitated easy removal post-testing for other types of characterization.</p>","PeriodicalId":15159,"journal":{"name":"Journal of biomedical materials research","volume":"48 6","pages":"829-32"},"PeriodicalIF":0.0000,"publicationDate":"1999-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1002/(sici)1097-4636(1999)48:6<829::aid-jbm10>3.0.co;2-#","citationCount":"31","resultStr":"{\"title\":\"Corrosion testing of stents: a novel fixture to hold entire device in deployed form and finish.\",\"authors\":\"R Venugopalan\",\"doi\":\"10.1002/(sici)1097-4636(1999)48:6<829::aid-jbm10>3.0.co;2-#\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Stainless steel and nickel-titanium alloy stents for cardiac, biliary, and prostatic clinical applications may be susceptible to loss of mechanical integrity/failure due to their small size and unique geometry. Because their corrosion behavior is a critical aspect of their biocompatibility, it is necessary to test such devices for corrosion behavior using a final deployed form and finish condition. Welding wire leads or holding with metallic clips can result in surface variability or damage to the stents. A novel fixture to hold stents for corrosion testing was designed and evaluated in this study. This fixture design minimally influenced the properties of stents, and also facilitated easy removal post-testing for other types of characterization.</p>\",\"PeriodicalId\":15159,\"journal\":{\"name\":\"Journal of biomedical materials research\",\"volume\":\"48 6\",\"pages\":\"829-32\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1999-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1002/(sici)1097-4636(1999)48:6<829::aid-jbm10>3.0.co;2-#\",\"citationCount\":\"31\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of biomedical materials research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1002/(sici)1097-4636(1999)48:6<829::aid-jbm10>3.0.co;2-#\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of biomedical materials research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1002/(sici)1097-4636(1999)48:6<829::aid-jbm10>3.0.co;2-#","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Corrosion testing of stents: a novel fixture to hold entire device in deployed form and finish.
Stainless steel and nickel-titanium alloy stents for cardiac, biliary, and prostatic clinical applications may be susceptible to loss of mechanical integrity/failure due to their small size and unique geometry. Because their corrosion behavior is a critical aspect of their biocompatibility, it is necessary to test such devices for corrosion behavior using a final deployed form and finish condition. Welding wire leads or holding with metallic clips can result in surface variability or damage to the stents. A novel fixture to hold stents for corrosion testing was designed and evaluated in this study. This fixture design minimally influenced the properties of stents, and also facilitated easy removal post-testing for other types of characterization.