{"title":"工人在两个垃圾衍生燃料厂暴露于微粒、内毒素和生物气溶胶。","authors":"S Mahar, S J Reynolds, P S Thorne","doi":"10.1080/00028899908984491","DOIUrl":null,"url":null,"abstract":"<p><p>Exposures of refuse-derived fuel (RDF) production workers to total particulates, endotoxin, and total (viable plus nonviable) bioaerosols were characterized at two RDF production plants. Full-shift personal air monitoring for 35 workers was conducted for total particulates, analyzed by gravimetric analysis; endotoxin, analyzed by chromogenic endpoint assay; and total bioaerosols, analyzed by fluorescent microscopy (FM). Geometric mean values of personal air samples were 0.50 mg/m3 for total dust, 29.0 EU/m3 (2.9 ng/m3) for endotoxin, and 6.8 x 10(5) organisms/m3 for bioaerosols. Significant differences were observed between the two plants only for total endotoxin exposures. The mean concentrations for total particulates, total FM bioaerosols, and endotoxins did not differ among the day, evening, or night shifts. Interjob differences were found for exposures to total dust, total endotoxin, and FM bioaerosols. Individual comparisons for total particulates and endotoxin exposures were significant for comparisons between job categories as a result of the greater exposures for personnel cleaning the plants. Significant correlations were detected between total particulates and total endotoxin measurements and between inhalable and total particulates.</p>","PeriodicalId":7930,"journal":{"name":"American Industrial Hygiene Association journal","volume":"60 5","pages":"679-83"},"PeriodicalIF":0.0000,"publicationDate":"1999-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1080/00028899908984491","citationCount":"17","resultStr":"{\"title\":\"Worker exposures to particulates, endotoxins, and bioaerosols in two refuse-derived fuel plants.\",\"authors\":\"S Mahar, S J Reynolds, P S Thorne\",\"doi\":\"10.1080/00028899908984491\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Exposures of refuse-derived fuel (RDF) production workers to total particulates, endotoxin, and total (viable plus nonviable) bioaerosols were characterized at two RDF production plants. Full-shift personal air monitoring for 35 workers was conducted for total particulates, analyzed by gravimetric analysis; endotoxin, analyzed by chromogenic endpoint assay; and total bioaerosols, analyzed by fluorescent microscopy (FM). Geometric mean values of personal air samples were 0.50 mg/m3 for total dust, 29.0 EU/m3 (2.9 ng/m3) for endotoxin, and 6.8 x 10(5) organisms/m3 for bioaerosols. Significant differences were observed between the two plants only for total endotoxin exposures. The mean concentrations for total particulates, total FM bioaerosols, and endotoxins did not differ among the day, evening, or night shifts. Interjob differences were found for exposures to total dust, total endotoxin, and FM bioaerosols. Individual comparisons for total particulates and endotoxin exposures were significant for comparisons between job categories as a result of the greater exposures for personnel cleaning the plants. Significant correlations were detected between total particulates and total endotoxin measurements and between inhalable and total particulates.</p>\",\"PeriodicalId\":7930,\"journal\":{\"name\":\"American Industrial Hygiene Association journal\",\"volume\":\"60 5\",\"pages\":\"679-83\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1999-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1080/00028899908984491\",\"citationCount\":\"17\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"American Industrial Hygiene Association journal\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1080/00028899908984491\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"American Industrial Hygiene Association journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/00028899908984491","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 17
摘要
在两个垃圾衍生燃料生产工厂,研究了垃圾衍生燃料生产工人暴露于总微粒、内毒素和总(可活的和不可活的)生物气溶胶的特征。对35名工人进行全班个人空气总颗粒物监测,采用重量分析法进行分析;内毒素,显色终点法分析;和总生物气溶胶,荧光显微镜(FM)分析。个人空气样本的几何平均值为总粉尘0.50 mg/m3,内毒素29.0 EU/m3 (2.9 ng/m3),生物气溶胶6.8 x 10(5)个生物体/m3。两种植物仅在总内毒素暴露量上观察到显著差异。总颗粒物、总FM生物气溶胶和内毒素的平均浓度在白班、夜班和夜班之间没有差异。暴露于总粉尘、总内毒素和FM生物气溶胶的工作间存在差异。总颗粒物和内毒素暴露的个体比较对于不同工作类别的比较具有重要意义,因为清洁工厂的人员暴露量较大。在总颗粒物和总内毒素测量之间以及可吸入颗粒物和总颗粒物之间检测到显著相关性。
Worker exposures to particulates, endotoxins, and bioaerosols in two refuse-derived fuel plants.
Exposures of refuse-derived fuel (RDF) production workers to total particulates, endotoxin, and total (viable plus nonviable) bioaerosols were characterized at two RDF production plants. Full-shift personal air monitoring for 35 workers was conducted for total particulates, analyzed by gravimetric analysis; endotoxin, analyzed by chromogenic endpoint assay; and total bioaerosols, analyzed by fluorescent microscopy (FM). Geometric mean values of personal air samples were 0.50 mg/m3 for total dust, 29.0 EU/m3 (2.9 ng/m3) for endotoxin, and 6.8 x 10(5) organisms/m3 for bioaerosols. Significant differences were observed between the two plants only for total endotoxin exposures. The mean concentrations for total particulates, total FM bioaerosols, and endotoxins did not differ among the day, evening, or night shifts. Interjob differences were found for exposures to total dust, total endotoxin, and FM bioaerosols. Individual comparisons for total particulates and endotoxin exposures were significant for comparisons between job categories as a result of the greater exposures for personnel cleaning the plants. Significant correlations were detected between total particulates and total endotoxin measurements and between inhalable and total particulates.