锁骨下支架和支架移植物:值得关注吗?

L H Phipp, D J Scott, D Kessel, I Robertson
{"title":"锁骨下支架和支架移植物:值得关注吗?","authors":"L H Phipp,&nbsp;D J Scott,&nbsp;D Kessel,&nbsp;I Robertson","doi":"10.1177/152660289900600302","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To report cases of stent and stent-graft fracture in the subclavian vessels.</p><p><strong>Methods and results: </strong>Three patients with self-expanding stents of 3 different types in 1 subclavian artery and 2 subclavian veins presented with recurrent symptoms 6 months to 2 years after stenting. All devices showed signs of compression with stent fracture. The covered stent in the subclavian artery was excised. Of the 2 venous patients, 1 was treated with first rib resection and the other refused further treatment.</p><p><strong>Conclusions: </strong>The subclavian vessels are prone to flexion during movement, and the vessels may be compressed by external structures, including the clavicle and first rib. Stents that have not been designed to withstand these forces may be damaged.</p>","PeriodicalId":79443,"journal":{"name":"Journal of endovascular surgery : the official journal of the International Society for Endovascular Surgery","volume":"6 3","pages":"223-6"},"PeriodicalIF":0.0000,"publicationDate":"1999-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1177/152660289900600302","citationCount":"0","resultStr":"{\"title\":\"Subclavian stents and stent-grafts: cause for concern?\",\"authors\":\"L H Phipp,&nbsp;D J Scott,&nbsp;D Kessel,&nbsp;I Robertson\",\"doi\":\"10.1177/152660289900600302\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To report cases of stent and stent-graft fracture in the subclavian vessels.</p><p><strong>Methods and results: </strong>Three patients with self-expanding stents of 3 different types in 1 subclavian artery and 2 subclavian veins presented with recurrent symptoms 6 months to 2 years after stenting. All devices showed signs of compression with stent fracture. The covered stent in the subclavian artery was excised. Of the 2 venous patients, 1 was treated with first rib resection and the other refused further treatment.</p><p><strong>Conclusions: </strong>The subclavian vessels are prone to flexion during movement, and the vessels may be compressed by external structures, including the clavicle and first rib. Stents that have not been designed to withstand these forces may be damaged.</p>\",\"PeriodicalId\":79443,\"journal\":{\"name\":\"Journal of endovascular surgery : the official journal of the International Society for Endovascular Surgery\",\"volume\":\"6 3\",\"pages\":\"223-6\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1999-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1177/152660289900600302\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of endovascular surgery : the official journal of the International Society for Endovascular Surgery\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1177/152660289900600302\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of endovascular surgery : the official journal of the International Society for Endovascular Surgery","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/152660289900600302","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

目的:报道锁骨下血管内支架及支架-移植物骨折病例。方法与结果:3例置入1条锁骨下动脉和2条锁骨下静脉的3种不同类型自扩支架患者在支架置入后6个月至2年出现复发症状。所有器械均有受压伴支架断裂的迹象。切除锁骨下动脉覆盖支架。2例静脉患者中,1例行第一肋骨切除术,1例拒绝进一步治疗。结论:锁骨下血管在运动过程中容易发生屈曲,并可能受到锁骨、第一肋骨等外部结构的压迫。没有设计承受这些力的支架可能会损坏。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Subclavian stents and stent-grafts: cause for concern?

Purpose: To report cases of stent and stent-graft fracture in the subclavian vessels.

Methods and results: Three patients with self-expanding stents of 3 different types in 1 subclavian artery and 2 subclavian veins presented with recurrent symptoms 6 months to 2 years after stenting. All devices showed signs of compression with stent fracture. The covered stent in the subclavian artery was excised. Of the 2 venous patients, 1 was treated with first rib resection and the other refused further treatment.

Conclusions: The subclavian vessels are prone to flexion during movement, and the vessels may be compressed by external structures, including the clavicle and first rib. Stents that have not been designed to withstand these forces may be damaged.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信