环境烟草烟雾亚微米颗粒物在人呼吸道沉积的实验研究。

L Morawska, W Barron, J Hitchins
{"title":"环境烟草烟雾亚微米颗粒物在人呼吸道沉积的实验研究。","authors":"L Morawska,&nbsp;W Barron,&nbsp;J Hitchins","doi":"10.1080/00028899908984450","DOIUrl":null,"url":null,"abstract":"<p><p>Measurements of 15 nonsmokers and 3 smokers breathing environmental tobacco smoke (ETS), were conducted to study particle deposition within the human respiratory tract. The subjects inhaled ETS of count median diameter (CMD) of about 0.2 micron and geometric standard deviation (GSD) of 1.7 The particle size distribution in the submicrometer range in the inhaled and exhaled air from the subjects was measured using a scanning mobility particle sizer (SMPS). A deposition of 56.0 +/- 15.9% was observed for nonsmokers while breathing ETS through the nose and 48.7 +/- 11.6% while breathing ETS through the mouth. One individual tested four times gave an average deposition of 57.4 +/- 11.5%, providing an indication of intraindividual variation. Such a variation is expected since the breathing rate was not controlled in order that an indication of the deposition experienced on a day-to-day basis could be obtained. For nonsmokers the deposition while breathing through the mouth was lower than through the nose and the variability within the measurements was also lower for mouth breathing. The latter could be due to the variation in individual size and shape of the nasal passage. Smokers had, on average, a higher rate of deposition but also a higher interindividual variability making it difficult to draw conclusions with respect to the affect of smoking on ETS particle deposition. The average deposition of the three smokers was 65.3 +/- 24.1% for nasal breathing and 66.1 +/- 17.6% for mouth breathing.</p>","PeriodicalId":7930,"journal":{"name":"American Industrial Hygiene Association journal","volume":"60 3","pages":"334-9"},"PeriodicalIF":0.0000,"publicationDate":"1999-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1080/00028899908984450","citationCount":"46","resultStr":"{\"title\":\"Experimental deposition of environmental tobacco smoke submicrometer particulate matter in the human respiratory tract.\",\"authors\":\"L Morawska,&nbsp;W Barron,&nbsp;J Hitchins\",\"doi\":\"10.1080/00028899908984450\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Measurements of 15 nonsmokers and 3 smokers breathing environmental tobacco smoke (ETS), were conducted to study particle deposition within the human respiratory tract. The subjects inhaled ETS of count median diameter (CMD) of about 0.2 micron and geometric standard deviation (GSD) of 1.7 The particle size distribution in the submicrometer range in the inhaled and exhaled air from the subjects was measured using a scanning mobility particle sizer (SMPS). A deposition of 56.0 +/- 15.9% was observed for nonsmokers while breathing ETS through the nose and 48.7 +/- 11.6% while breathing ETS through the mouth. One individual tested four times gave an average deposition of 57.4 +/- 11.5%, providing an indication of intraindividual variation. Such a variation is expected since the breathing rate was not controlled in order that an indication of the deposition experienced on a day-to-day basis could be obtained. For nonsmokers the deposition while breathing through the mouth was lower than through the nose and the variability within the measurements was also lower for mouth breathing. The latter could be due to the variation in individual size and shape of the nasal passage. Smokers had, on average, a higher rate of deposition but also a higher interindividual variability making it difficult to draw conclusions with respect to the affect of smoking on ETS particle deposition. The average deposition of the three smokers was 65.3 +/- 24.1% for nasal breathing and 66.1 +/- 17.6% for mouth breathing.</p>\",\"PeriodicalId\":7930,\"journal\":{\"name\":\"American Industrial Hygiene Association journal\",\"volume\":\"60 3\",\"pages\":\"334-9\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1999-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1080/00028899908984450\",\"citationCount\":\"46\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"American Industrial Hygiene Association journal\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1080/00028899908984450\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"American Industrial Hygiene Association journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/00028899908984450","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 46

摘要

对15名不吸烟者和3名吸入环境烟草烟雾的吸烟者进行了测量,以研究人体呼吸道内的颗粒沉积。被试吸入的ETS中位数直径(CMD)约为0.2微米,几何标准偏差(GSD)约为1.7微米。采用扫描迁移率粒度仪(SMPS)测量被试吸入和呼出空气中亚微米范围内的粒径分布。在非吸烟者中,通过鼻腔呼吸ETS时的沉积为56.0 +/- 15.9%,而通过口腔呼吸时的沉积为48.7 +/- 11.6%。一个个体测试了四次,平均沉积为57.4 +/- 11.5%,提供了个体内部差异的指示。这种变化是可以预料到的,因为没有控制呼吸速率,以便可以获得每天所经历的沉积的指示。对于不吸烟的人来说,用嘴呼吸时的沉积比用鼻子呼吸时的沉积要低,而且用嘴呼吸时测量结果的变异性也更低。后者可能是由于个体大小和鼻腔通道形状的差异。吸烟者的平均沉降率较高,但个体间差异也较大,因此很难得出吸烟对排放交易系统颗粒沉降影响的结论。3名吸烟者鼻腔呼吸的平均沉积量为65.3 +/- 24.1%,口腔呼吸的平均沉积量为66.1 +/- 17.6%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Experimental deposition of environmental tobacco smoke submicrometer particulate matter in the human respiratory tract.

Measurements of 15 nonsmokers and 3 smokers breathing environmental tobacco smoke (ETS), were conducted to study particle deposition within the human respiratory tract. The subjects inhaled ETS of count median diameter (CMD) of about 0.2 micron and geometric standard deviation (GSD) of 1.7 The particle size distribution in the submicrometer range in the inhaled and exhaled air from the subjects was measured using a scanning mobility particle sizer (SMPS). A deposition of 56.0 +/- 15.9% was observed for nonsmokers while breathing ETS through the nose and 48.7 +/- 11.6% while breathing ETS through the mouth. One individual tested four times gave an average deposition of 57.4 +/- 11.5%, providing an indication of intraindividual variation. Such a variation is expected since the breathing rate was not controlled in order that an indication of the deposition experienced on a day-to-day basis could be obtained. For nonsmokers the deposition while breathing through the mouth was lower than through the nose and the variability within the measurements was also lower for mouth breathing. The latter could be due to the variation in individual size and shape of the nasal passage. Smokers had, on average, a higher rate of deposition but also a higher interindividual variability making it difficult to draw conclusions with respect to the affect of smoking on ETS particle deposition. The average deposition of the three smokers was 65.3 +/- 24.1% for nasal breathing and 66.1 +/- 17.6% for mouth breathing.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信