电子生育指标Ladycomp/Babycomp避孕效果的回顾性临床试验。

G Freundl, P Frank-Herrmann, E Godehardt, R Klemm, M Bachhofer
{"title":"电子生育指标Ladycomp/Babycomp避孕效果的回顾性临床试验。","authors":"G Freundl,&nbsp;P Frank-Herrmann,&nbsp;E Godehardt,&nbsp;R Klemm,&nbsp;M Bachhofer","doi":"10.1023/a:1006534632583","DOIUrl":null,"url":null,"abstract":"<p><p>The Babycomp/Ladycomp (Valley Electronics Ltd., Eschenlohe, Germany) is an electronic device that combines the temperature method and calendar method for planning and preventing pregnancy by identifying the fertile and infertile phases of the menstrual cycle. In a retrospective clinical trial, the system was tested as a contraceptive aid. A total of 648 women from Germany and Switzerland have participated: 597 women with 10,275 months of use used the device for contraception. Thirty-three unplanned pregnancies were identified, giving a total pregnancy rate of 3.8 use effectiveness according to the Pearl Index. Six method-related pregnancies occurred, producing a method Pearl Index of 0.7. Calculating the cumulative pregnancy rates by life-table analysis, it was found that, after about one year of exposure, the probability of an unintended pregnancy was 5.3% (0.053), after 2 years it was 6.8% (0.068) and after about 3 years of exposure it was 8.2% (0.082). The mean length of the identified fertile period was 14.3 days with a standard deviation of 4.6 days in all cycles reported. The acceptance of the device by the woman and her partner was good. In fact, 21 of the 33 women who became pregnant would still recommend the device for further use (63.6%).</p>","PeriodicalId":76977,"journal":{"name":"Advances in contraception : the official journal of the Society for the Advancement of Contraception","volume":"14 2","pages":"97-108"},"PeriodicalIF":0.0000,"publicationDate":"1998-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1023/a:1006534632583","citationCount":"29","resultStr":"{\"title\":\"Retrospective clinical trial of contraceptive effectiveness of the electronic fertility indicator Ladycomp/Babycomp.\",\"authors\":\"G Freundl,&nbsp;P Frank-Herrmann,&nbsp;E Godehardt,&nbsp;R Klemm,&nbsp;M Bachhofer\",\"doi\":\"10.1023/a:1006534632583\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The Babycomp/Ladycomp (Valley Electronics Ltd., Eschenlohe, Germany) is an electronic device that combines the temperature method and calendar method for planning and preventing pregnancy by identifying the fertile and infertile phases of the menstrual cycle. In a retrospective clinical trial, the system was tested as a contraceptive aid. A total of 648 women from Germany and Switzerland have participated: 597 women with 10,275 months of use used the device for contraception. Thirty-three unplanned pregnancies were identified, giving a total pregnancy rate of 3.8 use effectiveness according to the Pearl Index. Six method-related pregnancies occurred, producing a method Pearl Index of 0.7. Calculating the cumulative pregnancy rates by life-table analysis, it was found that, after about one year of exposure, the probability of an unintended pregnancy was 5.3% (0.053), after 2 years it was 6.8% (0.068) and after about 3 years of exposure it was 8.2% (0.082). The mean length of the identified fertile period was 14.3 days with a standard deviation of 4.6 days in all cycles reported. The acceptance of the device by the woman and her partner was good. In fact, 21 of the 33 women who became pregnant would still recommend the device for further use (63.6%).</p>\",\"PeriodicalId\":76977,\"journal\":{\"name\":\"Advances in contraception : the official journal of the Society for the Advancement of Contraception\",\"volume\":\"14 2\",\"pages\":\"97-108\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1998-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1023/a:1006534632583\",\"citationCount\":\"29\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Advances in contraception : the official journal of the Society for the Advancement of Contraception\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1023/a:1006534632583\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Advances in contraception : the official journal of the Society for the Advancement of Contraception","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1023/a:1006534632583","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 29

摘要

Babycomp/Ladycomp (Valley Electronics Ltd., Eschenlohe, Germany)是一种结合温度法和日历法的电子设备,通过识别月经周期的可生育和不育阶段来计划和预防怀孕。在一项回顾性临床试验中,该系统作为一种避孕辅助工具进行了测试。共有648名来自德国和瑞士的妇女参加了该项目:597名妇女使用了10275个月的避孕装置。发现了33例意外怀孕,根据珍珠指数,总怀孕率为3.8。6例与方法相关的妊娠发生,方法珍珠指数为0.7。通过生命表分析计算累积妊娠率,发现暴露约1年后意外妊娠概率为5.3%(0.053),2年后为6.8%(0.068),3年后为8.2%(0.082)。确定的生育期平均长度为14.3天,所有周期的标准差为4.6天。这名妇女和她的伴侣对该设备的接受度很好。事实上,33名怀孕的妇女中有21名(63.6%)仍然建议进一步使用该装置。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Retrospective clinical trial of contraceptive effectiveness of the electronic fertility indicator Ladycomp/Babycomp.

The Babycomp/Ladycomp (Valley Electronics Ltd., Eschenlohe, Germany) is an electronic device that combines the temperature method and calendar method for planning and preventing pregnancy by identifying the fertile and infertile phases of the menstrual cycle. In a retrospective clinical trial, the system was tested as a contraceptive aid. A total of 648 women from Germany and Switzerland have participated: 597 women with 10,275 months of use used the device for contraception. Thirty-three unplanned pregnancies were identified, giving a total pregnancy rate of 3.8 use effectiveness according to the Pearl Index. Six method-related pregnancies occurred, producing a method Pearl Index of 0.7. Calculating the cumulative pregnancy rates by life-table analysis, it was found that, after about one year of exposure, the probability of an unintended pregnancy was 5.3% (0.053), after 2 years it was 6.8% (0.068) and after about 3 years of exposure it was 8.2% (0.082). The mean length of the identified fertile period was 14.3 days with a standard deviation of 4.6 days in all cycles reported. The acceptance of the device by the woman and her partner was good. In fact, 21 of the 33 women who became pregnant would still recommend the device for further use (63.6%).

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信