{"title":"传导性听力损失的实耳测量:探头管麦克风测量结果与声场测试结果之间的差异。","authors":"V C Cleaver","doi":"10.3109/03005364000000064","DOIUrl":null,"url":null,"abstract":"<p><p>This study was designed to investigate earlier observations that probe-tube microphone measurements of insertion gain overestimates the functional gain received from hearing aids by users with significant conductive hearing losses. This was originally thought to be due to artefacts in the probe-tube measurement caused by middle ear pathology, but is now believed to be the result of the bone conduction stimulation of the ear exposed to high intensities of airborne sound during sound field threshold measurements. Since the functional gain must relate to the true aided benefit in such cases, these findings suggest that probe-tube microphone measurements in ears with significant air-bone gaps should be interpreted with caution.</p>","PeriodicalId":75616,"journal":{"name":"British journal of audiology","volume":"32 3","pages":"205-9"},"PeriodicalIF":0.0000,"publicationDate":"1998-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.3109/03005364000000064","citationCount":"1","resultStr":"{\"title\":\"Real-ear measurements in conductive hearing loss: discrepancies between probe-tube microphone measurements and sound field test results.\",\"authors\":\"V C Cleaver\",\"doi\":\"10.3109/03005364000000064\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>This study was designed to investigate earlier observations that probe-tube microphone measurements of insertion gain overestimates the functional gain received from hearing aids by users with significant conductive hearing losses. This was originally thought to be due to artefacts in the probe-tube measurement caused by middle ear pathology, but is now believed to be the result of the bone conduction stimulation of the ear exposed to high intensities of airborne sound during sound field threshold measurements. Since the functional gain must relate to the true aided benefit in such cases, these findings suggest that probe-tube microphone measurements in ears with significant air-bone gaps should be interpreted with caution.</p>\",\"PeriodicalId\":75616,\"journal\":{\"name\":\"British journal of audiology\",\"volume\":\"32 3\",\"pages\":\"205-9\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1998-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.3109/03005364000000064\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"British journal of audiology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3109/03005364000000064\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"British journal of audiology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3109/03005364000000064","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

本研究旨在调查早期的观察结果,即探针管麦克风测量的插入增益高估了具有严重传导性听力损失的用户从助听器获得的功能增益。这最初被认为是由于中耳病理引起的探头管测量中的伪影,但现在被认为是在声场阈值测量期间暴露于高强度空气传播声音的耳朵骨传导刺激的结果。由于在这种情况下,功能增益必须与真正的辅助益处相关,因此这些研究结果表明,在具有明显气骨间隙的耳中,探头管麦克风测量结果应谨慎解释。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Real-ear measurements in conductive hearing loss: discrepancies between probe-tube microphone measurements and sound field test results.

This study was designed to investigate earlier observations that probe-tube microphone measurements of insertion gain overestimates the functional gain received from hearing aids by users with significant conductive hearing losses. This was originally thought to be due to artefacts in the probe-tube measurement caused by middle ear pathology, but is now believed to be the result of the bone conduction stimulation of the ear exposed to high intensities of airborne sound during sound field threshold measurements. Since the functional gain must relate to the true aided benefit in such cases, these findings suggest that probe-tube microphone measurements in ears with significant air-bone gaps should be interpreted with caution.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信