x射线显微镜:冷冻水合标本研究的准备。

Scanning microscopy. Supplement Pub Date : 1996-01-01
A Osanna, C Jacobsen, A Kalinovsky, J Kirz, J Maser, S Wang
{"title":"x射线显微镜:冷冻水合标本研究的准备。","authors":"A Osanna,&nbsp;C Jacobsen,&nbsp;A Kalinovsky,&nbsp;J Kirz,&nbsp;J Maser,&nbsp;S Wang","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>X-ray microscopes provide higher resolution than visible light microscopes. Wet, biological materials with a water thickness of up to about 10 microns can be imaged with good contrast using soft X-rays with wavelengths between the oxygen and carbon absorption edges (at 24 and 43 A). The Stony Brook group has developed and operates a scanning transmission X-ray microscope (STXM) at the National Synchrotron Light Source (NSLS) at Brookhaven National Laboratory. The microscope is used for imaging with a current resolution of 50 nm, and for elemental and chemical state mapping. Radiation damage imposes a significant limitation upon high resolution X-ray microscopy of room temperature wet specimens. Experience from electron microscopy suggests that cryo techniques allow vitrified specimens to be imaged repeatedly. This is due to the increased radiation stability of biological specimens in the frozen hydrated state. Better radiation stability has been shown recently with a cryo transmission X-ray microscope developed by the University of Göttingen, operating at the BESSY storage ring in Berlin, Germany. At Stony Brook, we are developing a cryo scanning transmission X-ray microscope (CryoSTXM) to carry out imaging and spectro-microscopy experiments on frozen hydrated specimens. This article will give an outlook onto the research projects that we plan to perform using the CryoSTXM.</p>","PeriodicalId":77379,"journal":{"name":"Scanning microscopy. Supplement","volume":"10 ","pages":"349-56; discussion 356-8"},"PeriodicalIF":0.0000,"publicationDate":"1996-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"X-ray microscopy: preparations for studies of frozen hydrated specimens.\",\"authors\":\"A Osanna,&nbsp;C Jacobsen,&nbsp;A Kalinovsky,&nbsp;J Kirz,&nbsp;J Maser,&nbsp;S Wang\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>X-ray microscopes provide higher resolution than visible light microscopes. Wet, biological materials with a water thickness of up to about 10 microns can be imaged with good contrast using soft X-rays with wavelengths between the oxygen and carbon absorption edges (at 24 and 43 A). The Stony Brook group has developed and operates a scanning transmission X-ray microscope (STXM) at the National Synchrotron Light Source (NSLS) at Brookhaven National Laboratory. The microscope is used for imaging with a current resolution of 50 nm, and for elemental and chemical state mapping. Radiation damage imposes a significant limitation upon high resolution X-ray microscopy of room temperature wet specimens. Experience from electron microscopy suggests that cryo techniques allow vitrified specimens to be imaged repeatedly. This is due to the increased radiation stability of biological specimens in the frozen hydrated state. Better radiation stability has been shown recently with a cryo transmission X-ray microscope developed by the University of Göttingen, operating at the BESSY storage ring in Berlin, Germany. At Stony Brook, we are developing a cryo scanning transmission X-ray microscope (CryoSTXM) to carry out imaging and spectro-microscopy experiments on frozen hydrated specimens. This article will give an outlook onto the research projects that we plan to perform using the CryoSTXM.</p>\",\"PeriodicalId\":77379,\"journal\":{\"name\":\"Scanning microscopy. Supplement\",\"volume\":\"10 \",\"pages\":\"349-56; discussion 356-8\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1996-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Scanning microscopy. Supplement\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Scanning microscopy. Supplement","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

x射线显微镜的分辨率比可见光显微镜高。水厚度约为10微米的湿生物材料可以使用波长在氧和碳吸收边缘(24和43 a)之间的软x射线进行成像,具有良好的对比度。石溪小组在布鲁克海文国家实验室的国家同步加速器光源(NSLS)开发并操作扫描透射x射线显微镜(STXM)。该显微镜用于成像,当前分辨率为50纳米,并用于元素和化学状态映射。辐射损伤对室温湿样的高分辨率x射线显微成像有很大的限制。电子显微镜的经验表明,冷冻技术可以使玻璃化的标本反复成像。这是由于生物标本在冷冻水合状态下的辐射稳定性增加。最近,由Göttingen大学开发的一种低温透射x射线显微镜显示出更好的辐射稳定性,该显微镜在德国柏林的BESSY储存环上运行。在石溪,我们正在开发一种低温扫描透射x射线显微镜(CryoSTXM),用于对冷冻水合标本进行成像和光谱显微镜实验。本文将展望我们计划使用CryoSTXM执行的研究项目。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
X-ray microscopy: preparations for studies of frozen hydrated specimens.

X-ray microscopes provide higher resolution than visible light microscopes. Wet, biological materials with a water thickness of up to about 10 microns can be imaged with good contrast using soft X-rays with wavelengths between the oxygen and carbon absorption edges (at 24 and 43 A). The Stony Brook group has developed and operates a scanning transmission X-ray microscope (STXM) at the National Synchrotron Light Source (NSLS) at Brookhaven National Laboratory. The microscope is used for imaging with a current resolution of 50 nm, and for elemental and chemical state mapping. Radiation damage imposes a significant limitation upon high resolution X-ray microscopy of room temperature wet specimens. Experience from electron microscopy suggests that cryo techniques allow vitrified specimens to be imaged repeatedly. This is due to the increased radiation stability of biological specimens in the frozen hydrated state. Better radiation stability has been shown recently with a cryo transmission X-ray microscope developed by the University of Göttingen, operating at the BESSY storage ring in Berlin, Germany. At Stony Brook, we are developing a cryo scanning transmission X-ray microscope (CryoSTXM) to carry out imaging and spectro-microscopy experiments on frozen hydrated specimens. This article will give an outlook onto the research projects that we plan to perform using the CryoSTXM.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信