失败的腋窝臂丛阻滞技术导致高血浆浓度的甲哌卡因。

Regional anesthesia Pub Date : 1997-11-01
K Yamamoto, T Nomura, K Shibata, S Ohmura
{"title":"失败的腋窝臂丛阻滞技术导致高血浆浓度的甲哌卡因。","authors":"K Yamamoto,&nbsp;T Nomura,&nbsp;K Shibata,&nbsp;S Ohmura","doi":"","DOIUrl":null,"url":null,"abstract":"<p><strong>Background and objectives: </strong>Unintentional extrasheath injection causes failed axillary brachial plexus block. We wanted to find out if extrasheath injections produce higher plasma concentrations of local anesthetics compared to intrasheath injections. We also studied the incidence of extrasheath injection with radiographs.</p><p><strong>Methods: </strong>Axillary brachial plexus blocks were established using a catheter technique. Fifty milliliters of 1.5% mepivacaine without epinephrine mixed with contrast medium was injected through the catheter. An anteroposterior radiograph was used to determine the distribution of contrast medium. Mepivacaine concentrations in arterial plasma were compared when local anesthetic solution was injected unintentionally outside of the axillary neurovascular sheath (n = 6) and when it was injected correctly into the sheath (n = 6). The incidence of extrasheath injection was studied in a different series of 109 patients.</p><p><strong>Results: </strong>Arterial plasma mepivacaine concentrations were higher after extrasheath injection [8.0 (6.3-9.7) vs 5.8 (4.5-7.0), microg/mL, means (95% confidence intervals), P < .05]. Pharmacokinetic parameters such as mean residence time and total clearance did not differ between intra- and extrasheath injections. Extrasheath injection was observed in 3.7% (4/109) of cases.</p><p><strong>Conclusion: </strong>Failed extrasheath injection of 50 mL 1.5% plain mepivacaine produces higher arterial plasma concentration in axillary brachial plexus block.</p>","PeriodicalId":77347,"journal":{"name":"Regional anesthesia","volume":"22 6","pages":"557-61"},"PeriodicalIF":0.0000,"publicationDate":"1997-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Failed axillary brachial plexus block techniques result in high plasma concentrations of mepivacaine.\",\"authors\":\"K Yamamoto,&nbsp;T Nomura,&nbsp;K Shibata,&nbsp;S Ohmura\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background and objectives: </strong>Unintentional extrasheath injection causes failed axillary brachial plexus block. We wanted to find out if extrasheath injections produce higher plasma concentrations of local anesthetics compared to intrasheath injections. We also studied the incidence of extrasheath injection with radiographs.</p><p><strong>Methods: </strong>Axillary brachial plexus blocks were established using a catheter technique. Fifty milliliters of 1.5% mepivacaine without epinephrine mixed with contrast medium was injected through the catheter. An anteroposterior radiograph was used to determine the distribution of contrast medium. Mepivacaine concentrations in arterial plasma were compared when local anesthetic solution was injected unintentionally outside of the axillary neurovascular sheath (n = 6) and when it was injected correctly into the sheath (n = 6). The incidence of extrasheath injection was studied in a different series of 109 patients.</p><p><strong>Results: </strong>Arterial plasma mepivacaine concentrations were higher after extrasheath injection [8.0 (6.3-9.7) vs 5.8 (4.5-7.0), microg/mL, means (95% confidence intervals), P < .05]. Pharmacokinetic parameters such as mean residence time and total clearance did not differ between intra- and extrasheath injections. Extrasheath injection was observed in 3.7% (4/109) of cases.</p><p><strong>Conclusion: </strong>Failed extrasheath injection of 50 mL 1.5% plain mepivacaine produces higher arterial plasma concentration in axillary brachial plexus block.</p>\",\"PeriodicalId\":77347,\"journal\":{\"name\":\"Regional anesthesia\",\"volume\":\"22 6\",\"pages\":\"557-61\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1997-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Regional anesthesia\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Regional anesthesia","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

背景和目的:无意的鞘外注射导致腋窝臂丛阻滞失败。我们想知道与鞘内注射相比,鞘外注射是否会产生更高的局部麻醉药血浆浓度。我们还通过x线片研究了鞘外注射的发生率。方法:采用导管技术建立腋窝臂丛神经阻滞。经导管注射1.5%不含肾上腺素的甲哌卡因50毫升,与造影剂混合。用正位x线片确定造影剂的分布。比较了局麻溶液在腋神经血管鞘外非故意注射(n = 6)和正确注射(n = 6)时动脉血浆中甲哌卡因的浓度,并对109例不同系列患者的鞘外注射发生率进行了研究。结果:经皮外注射后动脉血浆甲哌卡因浓度较高[8.0 (6.3-9.7)vs 5.8 (4.5-7.0), μ g/mL,平均值(95%可信区间),P < 0.05]。药代动力学参数,如平均停留时间和总清除率在内注射和外注射之间没有差异。3.7%(4/109)的病例使用外鞘注射液。结论:50 mL 1.5%普通甲哌卡因在腋窝臂丛阻滞失败后可引起较高的动脉血药浓度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Failed axillary brachial plexus block techniques result in high plasma concentrations of mepivacaine.

Background and objectives: Unintentional extrasheath injection causes failed axillary brachial plexus block. We wanted to find out if extrasheath injections produce higher plasma concentrations of local anesthetics compared to intrasheath injections. We also studied the incidence of extrasheath injection with radiographs.

Methods: Axillary brachial plexus blocks were established using a catheter technique. Fifty milliliters of 1.5% mepivacaine without epinephrine mixed with contrast medium was injected through the catheter. An anteroposterior radiograph was used to determine the distribution of contrast medium. Mepivacaine concentrations in arterial plasma were compared when local anesthetic solution was injected unintentionally outside of the axillary neurovascular sheath (n = 6) and when it was injected correctly into the sheath (n = 6). The incidence of extrasheath injection was studied in a different series of 109 patients.

Results: Arterial plasma mepivacaine concentrations were higher after extrasheath injection [8.0 (6.3-9.7) vs 5.8 (4.5-7.0), microg/mL, means (95% confidence intervals), P < .05]. Pharmacokinetic parameters such as mean residence time and total clearance did not differ between intra- and extrasheath injections. Extrasheath injection was observed in 3.7% (4/109) of cases.

Conclusion: Failed extrasheath injection of 50 mL 1.5% plain mepivacaine produces higher arterial plasma concentration in axillary brachial plexus block.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信