使用热指标测量全身血流量的争论。

J Takala
{"title":"使用热指标测量全身血流量的争论。","authors":"J Takala","doi":"10.1111/j.1399-6576.1997.tb05534.x","DOIUrl":null,"url":null,"abstract":"Measurement of cardiac output by thermodilution is the established standard method for the evaluation of whole body blood flow in critically ill patients. Its main advantages are practicality, feasibility for routine clinical use, ease of user training, and wellestablished sources of variability and error. Comparisons against the golden standard, the Fick method, indicates acceptable bias and precision and good correlation in detecting changes in trends (1). The negative bias (smaller values with the thermodilution) observed in several recent studies in the critically ill patients is at least in part due to the increased oxygen consumption of the lung in acute inflammation (2). The recently introduced continual thermodilution methods offer the additional advantage of automated, continual trending of cardiac output (3). Since cardiac output is a variable with both rapid and slower dynamic variability, it is conceivable that the measurement of thermodilution cardiac output is bound to have variability, which is a function of the dynamic variability of actual cardiac output and the error of he method (4). Large fluctuations in airway temperature in patients with acute respiratory distress may accentuate the variability due to unstable pulmonary artery temperature. These sources of variability can be satisfactorily controlled by performing the injections randomly over the respiratory cycle and accepting only those measurements with an appropriately shaped thermal dilution curve, and increasing the number of measurements, when the variability is high.","PeriodicalId":75373,"journal":{"name":"Acta anaesthesiologica Scandinavica. Supplementum","volume":"110 ","pages":"138"},"PeriodicalIF":0.0000,"publicationDate":"1997-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1111/j.1399-6576.1997.tb05534.x","citationCount":"0","resultStr":"{\"title\":\"Arguments for the use of thermal indicators to measure whole body blood flow.\",\"authors\":\"J Takala\",\"doi\":\"10.1111/j.1399-6576.1997.tb05534.x\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Measurement of cardiac output by thermodilution is the established standard method for the evaluation of whole body blood flow in critically ill patients. Its main advantages are practicality, feasibility for routine clinical use, ease of user training, and wellestablished sources of variability and error. Comparisons against the golden standard, the Fick method, indicates acceptable bias and precision and good correlation in detecting changes in trends (1). The negative bias (smaller values with the thermodilution) observed in several recent studies in the critically ill patients is at least in part due to the increased oxygen consumption of the lung in acute inflammation (2). The recently introduced continual thermodilution methods offer the additional advantage of automated, continual trending of cardiac output (3). Since cardiac output is a variable with both rapid and slower dynamic variability, it is conceivable that the measurement of thermodilution cardiac output is bound to have variability, which is a function of the dynamic variability of actual cardiac output and the error of he method (4). Large fluctuations in airway temperature in patients with acute respiratory distress may accentuate the variability due to unstable pulmonary artery temperature. These sources of variability can be satisfactorily controlled by performing the injections randomly over the respiratory cycle and accepting only those measurements with an appropriately shaped thermal dilution curve, and increasing the number of measurements, when the variability is high.\",\"PeriodicalId\":75373,\"journal\":{\"name\":\"Acta anaesthesiologica Scandinavica. Supplementum\",\"volume\":\"110 \",\"pages\":\"138\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1997-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1111/j.1399-6576.1997.tb05534.x\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Acta anaesthesiologica Scandinavica. Supplementum\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1111/j.1399-6576.1997.tb05534.x\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta anaesthesiologica Scandinavica. Supplementum","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1111/j.1399-6576.1997.tb05534.x","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文章由计算机程序翻译,如有差异,请以英文原文为准。
Arguments for the use of thermal indicators to measure whole body blood flow.
Measurement of cardiac output by thermodilution is the established standard method for the evaluation of whole body blood flow in critically ill patients. Its main advantages are practicality, feasibility for routine clinical use, ease of user training, and wellestablished sources of variability and error. Comparisons against the golden standard, the Fick method, indicates acceptable bias and precision and good correlation in detecting changes in trends (1). The negative bias (smaller values with the thermodilution) observed in several recent studies in the critically ill patients is at least in part due to the increased oxygen consumption of the lung in acute inflammation (2). The recently introduced continual thermodilution methods offer the additional advantage of automated, continual trending of cardiac output (3). Since cardiac output is a variable with both rapid and slower dynamic variability, it is conceivable that the measurement of thermodilution cardiac output is bound to have variability, which is a function of the dynamic variability of actual cardiac output and the error of he method (4). Large fluctuations in airway temperature in patients with acute respiratory distress may accentuate the variability due to unstable pulmonary artery temperature. These sources of variability can be satisfactorily controlled by performing the injections randomly over the respiratory cycle and accepting only those measurements with an appropriately shaped thermal dilution curve, and increasing the number of measurements, when the variability is high.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信