棉和非织造双功能手术服的热舒适性能。

J S Cho, S Tanabe, G Cho
{"title":"棉和非织造双功能手术服的热舒适性能。","authors":"J S Cho,&nbsp;S Tanabe,&nbsp;G Cho","doi":"10.2114/jpa.16.87","DOIUrl":null,"url":null,"abstract":"<p><p>The purpose of this study was to evaluate thermal comfort properties of surgical gowns made of dual functional finish cotton and nonwoven fabrics which have barrier properties of blood and micro-organism. Four types of surgical gowns, which were made of nonwoven fabrics with finish or without and were made of cotton with finish or without, were tested. The thermal insulations of four surgical gowns were measured with thermal manikin. Subjective experiments on thermal comfort, skin temperature and clothing microclimate were conducted. Six male subjects, between 26 and 28 years age old, participated in the wear trials tests. Typical activities for surgeons in the operation theater were simulated during the experimental sessions. Air temperature in a climate chamber was kept at 22 degrees C and its humidity was 60% RH. Air velocity was controlled at less than 0.15 m/s. Inner radiant temperature was almost equal to the air temperature. Basic thermal insulation of the dual functional finished nonwoven surgical gown was 0.87 clo, which was slightly higher than that of untreated (0.84 clo). However, the skin temperature of the subject wearing a dual functional finished surgical gown was significantly lower at P < .05. When the subject wears the dual functional finished gown, the amount of sweating was less than that when wearing untreated. Microclimate temperature and humidity of dual functional finished surgical gown were lower than untreated and it was statistically significant. There was no significant difference in subjective humid and overall comfort sensation between finished and untreated ones. Thermal sensation of dual functional finished one was significantly different from untreated one only during the first exercise. The results of this study indicate that the dual functional finish surgical gown allowed heat to be transferred from the skin of subject to the atmosphere better than untreated. The nonwoven surgical gown showed no difference in comfort properties from cotton one.</p>","PeriodicalId":79317,"journal":{"name":"Applied human science : journal of physiological anthropology","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"1997-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.2114/jpa.16.87","citationCount":"18","resultStr":"{\"title\":\"Thermal comfort properties of cotton and nonwoven surgical gowns with dual functional finish.\",\"authors\":\"J S Cho,&nbsp;S Tanabe,&nbsp;G Cho\",\"doi\":\"10.2114/jpa.16.87\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The purpose of this study was to evaluate thermal comfort properties of surgical gowns made of dual functional finish cotton and nonwoven fabrics which have barrier properties of blood and micro-organism. Four types of surgical gowns, which were made of nonwoven fabrics with finish or without and were made of cotton with finish or without, were tested. The thermal insulations of four surgical gowns were measured with thermal manikin. Subjective experiments on thermal comfort, skin temperature and clothing microclimate were conducted. Six male subjects, between 26 and 28 years age old, participated in the wear trials tests. Typical activities for surgeons in the operation theater were simulated during the experimental sessions. Air temperature in a climate chamber was kept at 22 degrees C and its humidity was 60% RH. Air velocity was controlled at less than 0.15 m/s. Inner radiant temperature was almost equal to the air temperature. Basic thermal insulation of the dual functional finished nonwoven surgical gown was 0.87 clo, which was slightly higher than that of untreated (0.84 clo). However, the skin temperature of the subject wearing a dual functional finished surgical gown was significantly lower at P < .05. When the subject wears the dual functional finished gown, the amount of sweating was less than that when wearing untreated. Microclimate temperature and humidity of dual functional finished surgical gown were lower than untreated and it was statistically significant. There was no significant difference in subjective humid and overall comfort sensation between finished and untreated ones. Thermal sensation of dual functional finished one was significantly different from untreated one only during the first exercise. The results of this study indicate that the dual functional finish surgical gown allowed heat to be transferred from the skin of subject to the atmosphere better than untreated. The nonwoven surgical gown showed no difference in comfort properties from cotton one.</p>\",\"PeriodicalId\":79317,\"journal\":{\"name\":\"Applied human science : journal of physiological anthropology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1997-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.2114/jpa.16.87\",\"citationCount\":\"18\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Applied human science : journal of physiological anthropology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2114/jpa.16.87\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Applied human science : journal of physiological anthropology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2114/jpa.16.87","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 18

摘要

本研究的目的是评价具有血液和微生物屏障性能的双功能整理棉和非织造布制成的手术服的热舒适性。测试了四种类型的手术服,分别是由有整理和没有整理的无纺布制成的,以及由有整理和没有整理的棉质制成的。采用热人体模型对四种手术服的隔热性能进行了测量。对热舒适、皮肤温度和服装小气候进行了主观实验。六名年龄在26至28岁之间的男性受试者参加了磨损试验测试。在实验过程中模拟了外科医生在手术室的典型活动。气候室的空气温度保持在22摄氏度,相对湿度为60%。风速控制在0.15 m/s以下。内部辐射温度几乎等于空气温度。双功能成品无纺布手术衣的基本保温率为0.87 clo,略高于未处理手术衣的0.84 clo。然而,穿着双功能手术服的受试者皮肤温度显著降低(P < 0.05)。当受试者穿着双功能成品长袍时,出汗量比未穿的少。双功能手术衣的小气候温度和湿度低于未处理的手术衣,差异有统计学意义。实验结束后与未处理组的主观湿度和整体舒适度无显著差异。在第一次运动时,双功能完成组的热感觉与未完成组有显著差异。本研究结果表明,双功能光洁度手术服允许热量从受试者的皮肤转移到大气比未处理。无纺布手术衣的舒适性能与棉质手术衣没有差别。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Thermal comfort properties of cotton and nonwoven surgical gowns with dual functional finish.

The purpose of this study was to evaluate thermal comfort properties of surgical gowns made of dual functional finish cotton and nonwoven fabrics which have barrier properties of blood and micro-organism. Four types of surgical gowns, which were made of nonwoven fabrics with finish or without and were made of cotton with finish or without, were tested. The thermal insulations of four surgical gowns were measured with thermal manikin. Subjective experiments on thermal comfort, skin temperature and clothing microclimate were conducted. Six male subjects, between 26 and 28 years age old, participated in the wear trials tests. Typical activities for surgeons in the operation theater were simulated during the experimental sessions. Air temperature in a climate chamber was kept at 22 degrees C and its humidity was 60% RH. Air velocity was controlled at less than 0.15 m/s. Inner radiant temperature was almost equal to the air temperature. Basic thermal insulation of the dual functional finished nonwoven surgical gown was 0.87 clo, which was slightly higher than that of untreated (0.84 clo). However, the skin temperature of the subject wearing a dual functional finished surgical gown was significantly lower at P < .05. When the subject wears the dual functional finished gown, the amount of sweating was less than that when wearing untreated. Microclimate temperature and humidity of dual functional finished surgical gown were lower than untreated and it was statistically significant. There was no significant difference in subjective humid and overall comfort sensation between finished and untreated ones. Thermal sensation of dual functional finished one was significantly different from untreated one only during the first exercise. The results of this study indicate that the dual functional finish surgical gown allowed heat to be transferred from the skin of subject to the atmosphere better than untreated. The nonwoven surgical gown showed no difference in comfort properties from cotton one.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信