标准化根管指伸器与附件杜仲胶锥的兼容性。

O Zmener, R Hilu, R Scavo
{"title":"标准化根管指伸器与附件杜仲胶锥的兼容性。","authors":"O Zmener,&nbsp;R Hilu,&nbsp;R Scavo","doi":"10.1111/j.1600-9657.1996.tb00521.x","DOIUrl":null,"url":null,"abstract":"Twenty samples of each size designation of finger spreaders and accessory gutta-percha cones were randomly selected from a proprietary standardized system currently used for lateral condensation procedures. Their diameters were measured with a calliper and their morphological variations at the areas of their apical thirds were analyzed with the scanning electron microscope. Results of the measurements indicated that there were high degrees of variation between all spreaders and their corresponding accessory gutta-percha cones (p < 0.001). SEM examination showed the presence of many morphologic irregularities and lack of uniformity between spreaders and cones of the same size. Our results emphasize the need for more precise criteria to fulfill the requirements of standardization by the manufacturer to provide an accurate method for root canal obturation.","PeriodicalId":77113,"journal":{"name":"Endodontics & dental traumatology","volume":"12 5","pages":"237-9"},"PeriodicalIF":0.0000,"publicationDate":"1996-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1111/j.1600-9657.1996.tb00521.x","citationCount":"4","resultStr":"{\"title\":\"Compatibility between standardized endodontic finger spreaders and accessory gutta-percha cones.\",\"authors\":\"O Zmener,&nbsp;R Hilu,&nbsp;R Scavo\",\"doi\":\"10.1111/j.1600-9657.1996.tb00521.x\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Twenty samples of each size designation of finger spreaders and accessory gutta-percha cones were randomly selected from a proprietary standardized system currently used for lateral condensation procedures. Their diameters were measured with a calliper and their morphological variations at the areas of their apical thirds were analyzed with the scanning electron microscope. Results of the measurements indicated that there were high degrees of variation between all spreaders and their corresponding accessory gutta-percha cones (p < 0.001). SEM examination showed the presence of many morphologic irregularities and lack of uniformity between spreaders and cones of the same size. Our results emphasize the need for more precise criteria to fulfill the requirements of standardization by the manufacturer to provide an accurate method for root canal obturation.\",\"PeriodicalId\":77113,\"journal\":{\"name\":\"Endodontics & dental traumatology\",\"volume\":\"12 5\",\"pages\":\"237-9\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1996-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1111/j.1600-9657.1996.tb00521.x\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Endodontics & dental traumatology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1111/j.1600-9657.1996.tb00521.x\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Endodontics & dental traumatology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1111/j.1600-9657.1996.tb00521.x","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

摘要

从目前用于横向冷凝程序的专有标准化系统中随机选择各尺寸指定的手指展布和附件杜仲胶锥的20个样品。用卡尺测量了它们的直径,用扫描电镜分析了它们顶端三分之一区域的形态变化。测量结果表明,所有散布器及其相应的附属杜仲胶锥之间存在高度差异(p < 0.001)。扫描电镜(SEM)检查显示,相同大小的锥体和梭形体之间存在许多形态不规则和缺乏均匀性。我们的结果强调需要更精确的标准来满足制造商的标准化要求,以提供准确的根管封闭方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Compatibility between standardized endodontic finger spreaders and accessory gutta-percha cones.
Twenty samples of each size designation of finger spreaders and accessory gutta-percha cones were randomly selected from a proprietary standardized system currently used for lateral condensation procedures. Their diameters were measured with a calliper and their morphological variations at the areas of their apical thirds were analyzed with the scanning electron microscope. Results of the measurements indicated that there were high degrees of variation between all spreaders and their corresponding accessory gutta-percha cones (p < 0.001). SEM examination showed the presence of many morphologic irregularities and lack of uniformity between spreaders and cones of the same size. Our results emphasize the need for more precise criteria to fulfill the requirements of standardization by the manufacturer to provide an accurate method for root canal obturation.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信