A Kitajima, K Maekawa, K Yoshii, H Komatsu, T Tanimoto, S Okada
{"title":"[国家卫生科学研究所氰钴胺参考标准(Control 951)]。","authors":"A Kitajima, K Maekawa, K Yoshii, H Komatsu, T Tanimoto, S Okada","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>The raw material of cyanocobalamin was tested for preparation of the \"Cyanocobalamin Reference Standard (Control 951)\". Analytical data obtained are as follows: loss on drying, 1.8%; infrared spectrum, the same as that of the JP Cyanocobalamin Reference Standard (Control 936); thin-layer chromatography, three impurities were detected; high-performance liquid chromatography (HPLC), eight to nine kinds of impurities were detected and the total amount of impurities was estimated to be 1.6 +/- 0.13% (n = 4); assay, 99.7% by spectrophotometry specified in the JP XII and 100.4% by HPLC, respectively. Based on the above results, the raw material was authorized as the JP Cyanocobalamin Reference Standard (Control 951).</p>","PeriodicalId":11656,"journal":{"name":"Eisei Shikenjo hokoku. Bulletin of National Institute of Hygienic Sciences","volume":" 114","pages":"122-4"},"PeriodicalIF":0.0000,"publicationDate":"1996-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"[Cyanocobalamin Reference Standard (Control 951) of the National Institute of Health Sciences].\",\"authors\":\"A Kitajima, K Maekawa, K Yoshii, H Komatsu, T Tanimoto, S Okada\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The raw material of cyanocobalamin was tested for preparation of the \\\"Cyanocobalamin Reference Standard (Control 951)\\\". Analytical data obtained are as follows: loss on drying, 1.8%; infrared spectrum, the same as that of the JP Cyanocobalamin Reference Standard (Control 936); thin-layer chromatography, three impurities were detected; high-performance liquid chromatography (HPLC), eight to nine kinds of impurities were detected and the total amount of impurities was estimated to be 1.6 +/- 0.13% (n = 4); assay, 99.7% by spectrophotometry specified in the JP XII and 100.4% by HPLC, respectively. Based on the above results, the raw material was authorized as the JP Cyanocobalamin Reference Standard (Control 951).</p>\",\"PeriodicalId\":11656,\"journal\":{\"name\":\"Eisei Shikenjo hokoku. Bulletin of National Institute of Hygienic Sciences\",\"volume\":\" 114\",\"pages\":\"122-4\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1996-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Eisei Shikenjo hokoku. Bulletin of National Institute of Hygienic Sciences\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Eisei Shikenjo hokoku. Bulletin of National Institute of Hygienic Sciences","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
[Cyanocobalamin Reference Standard (Control 951) of the National Institute of Health Sciences].
The raw material of cyanocobalamin was tested for preparation of the "Cyanocobalamin Reference Standard (Control 951)". Analytical data obtained are as follows: loss on drying, 1.8%; infrared spectrum, the same as that of the JP Cyanocobalamin Reference Standard (Control 936); thin-layer chromatography, three impurities were detected; high-performance liquid chromatography (HPLC), eight to nine kinds of impurities were detected and the total amount of impurities was estimated to be 1.6 +/- 0.13% (n = 4); assay, 99.7% by spectrophotometry specified in the JP XII and 100.4% by HPLC, respectively. Based on the above results, the raw material was authorized as the JP Cyanocobalamin Reference Standard (Control 951).