改良肝素结合导管用于股静脉冠状窦插管。

K J Winters, J M Lasala, P R Eisenberg, S C Smith, D J Sewall, M E Shelton
{"title":"改良肝素结合导管用于股静脉冠状窦插管。","authors":"K J Winters,&nbsp;J M Lasala,&nbsp;P R Eisenberg,&nbsp;S C Smith,&nbsp;D J Sewall,&nbsp;M E Shelton","doi":"10.1002/(SICI)1097-0304(199612)39:4<433::AID-CCD25>3.0.CO;2-C","DOIUrl":null,"url":null,"abstract":"<p><p>Serial sampling from the coronary sinus is an attractive technique for drawing blood samples to be used in the characterization of procoagulant activity during coronary interventions. We have developed a modified Simmons catheter for rapid cannulation of the coronary sinus from the femoral approach. The catheter design incorporates heparin bonding and distal side-holes to minimize blood sampling artifacts. Coronary sinus cannulation was performed via the femoral approach in 186 patients by use of a multipurpose catheter (n = 8), an unmodified Simmons I or II catheter (n = 64), or the modified Simmons catheter (n = 114). The coronary sinus was cannulated successfully with the modified Simmons catheter in 97% of patients; the success rate with the unmodified Simmons II catheter was 87% (P = 0.02). The modified Simmons catheter represents an improved technique for cannulation of the coronary sinus from the femoral vein.</p>","PeriodicalId":9664,"journal":{"name":"Catheterization and cardiovascular diagnosis","volume":"39 4","pages":"433-7"},"PeriodicalIF":0.0000,"publicationDate":"1996-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":"{\"title\":\"Modified heparin-bonded catheter for cannulation of the coronary sinus from the femoral vein.\",\"authors\":\"K J Winters,&nbsp;J M Lasala,&nbsp;P R Eisenberg,&nbsp;S C Smith,&nbsp;D J Sewall,&nbsp;M E Shelton\",\"doi\":\"10.1002/(SICI)1097-0304(199612)39:4<433::AID-CCD25>3.0.CO;2-C\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Serial sampling from the coronary sinus is an attractive technique for drawing blood samples to be used in the characterization of procoagulant activity during coronary interventions. We have developed a modified Simmons catheter for rapid cannulation of the coronary sinus from the femoral approach. The catheter design incorporates heparin bonding and distal side-holes to minimize blood sampling artifacts. Coronary sinus cannulation was performed via the femoral approach in 186 patients by use of a multipurpose catheter (n = 8), an unmodified Simmons I or II catheter (n = 64), or the modified Simmons catheter (n = 114). The coronary sinus was cannulated successfully with the modified Simmons catheter in 97% of patients; the success rate with the unmodified Simmons II catheter was 87% (P = 0.02). The modified Simmons catheter represents an improved technique for cannulation of the coronary sinus from the femoral vein.</p>\",\"PeriodicalId\":9664,\"journal\":{\"name\":\"Catheterization and cardiovascular diagnosis\",\"volume\":\"39 4\",\"pages\":\"433-7\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1996-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"7\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Catheterization and cardiovascular diagnosis\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1002/(SICI)1097-0304(199612)39:4<433::AID-CCD25>3.0.CO;2-C\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Catheterization and cardiovascular diagnosis","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1002/(SICI)1097-0304(199612)39:4<433::AID-CCD25>3.0.CO;2-C","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 7

摘要

在冠状动脉介入治疗期间,从冠状动脉窦连续取样是一种有吸引力的血液样本提取技术,可用于表征促凝活性。我们开发了一种改良的Simmons导管,用于从股入路快速插管冠状窦。导管设计结合肝素结合和远端侧孔,以尽量减少血样伪影。186例患者经股入路行冠状动脉窦插管,分别使用多用途导管(n = 8)、未改良的Simmons I或II导管(n = 64)或改良的Simmons导管(n = 114)。改良Simmons导管冠脉窦插管成功率97%;未经改良的Simmons II导管的成功率为87% (P = 0.02)。改良的Simmons导管代表了一种从股静脉插管冠状窦的改进技术。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Modified heparin-bonded catheter for cannulation of the coronary sinus from the femoral vein.

Serial sampling from the coronary sinus is an attractive technique for drawing blood samples to be used in the characterization of procoagulant activity during coronary interventions. We have developed a modified Simmons catheter for rapid cannulation of the coronary sinus from the femoral approach. The catheter design incorporates heparin bonding and distal side-holes to minimize blood sampling artifacts. Coronary sinus cannulation was performed via the femoral approach in 186 patients by use of a multipurpose catheter (n = 8), an unmodified Simmons I or II catheter (n = 64), or the modified Simmons catheter (n = 114). The coronary sinus was cannulated successfully with the modified Simmons catheter in 97% of patients; the success rate with the unmodified Simmons II catheter was 87% (P = 0.02). The modified Simmons catheter represents an improved technique for cannulation of the coronary sinus from the femoral vein.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信