一种使用机器人工作站的放射配体结合测定方法。

B Cusack, E Richelson
{"title":"一种使用机器人工作站的放射配体结合测定方法。","authors":"B Cusack,&nbsp;E Richelson","doi":"10.3109/10799899309073650","DOIUrl":null,"url":null,"abstract":"<p><p>Radioligand binding assays provide a powerful tool for screening drug candidates at many receptors. We present a method utilizing a robotic workstation, the Biomek 1000, which automates the tedious and repetitive tasks of these assays. First, the robot handles the serial dilution of up to 8 drugs with 11 concentrations per drug. The sequential addition of diluting buffer, non-radioactively labeled ligand, radioactive ligand, and finally the tissue homogenate or membrane preparation, is fully automated. A novel rack design allows the use of tubes with a maximum capacity of 2 ml, providing a total assay volume of 1 ml. Final filtration on a Brandel cell harvester outfitted with a uniquely designed head allows for processing of 48 samples simultaneously from the rack holder. We have employed this method for the determination of equilibrium dissociation constants (Kds) for drugs at the 5 human muscarinic acetylcholine receptor subtypes expressed in cultured cells, as well as histamine H1, dopamine D2, serotonin 5HT1A, alpha 1- and alpha 2-adrenergic receptors in human brain tissue homogenates. Our results compare favorably with manual methods reported for these receptors, and exhibit a very high degree of reproducibility and throughput, with a minimum of operator input.</p>","PeriodicalId":16948,"journal":{"name":"Journal of receptor research","volume":"13 1-4","pages":"123-34"},"PeriodicalIF":0.0000,"publicationDate":"1993-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.3109/10799899309073650","citationCount":"17","resultStr":"{\"title\":\"A method for radioligand binding assays using a robotic workstation.\",\"authors\":\"B Cusack,&nbsp;E Richelson\",\"doi\":\"10.3109/10799899309073650\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Radioligand binding assays provide a powerful tool for screening drug candidates at many receptors. We present a method utilizing a robotic workstation, the Biomek 1000, which automates the tedious and repetitive tasks of these assays. First, the robot handles the serial dilution of up to 8 drugs with 11 concentrations per drug. The sequential addition of diluting buffer, non-radioactively labeled ligand, radioactive ligand, and finally the tissue homogenate or membrane preparation, is fully automated. A novel rack design allows the use of tubes with a maximum capacity of 2 ml, providing a total assay volume of 1 ml. Final filtration on a Brandel cell harvester outfitted with a uniquely designed head allows for processing of 48 samples simultaneously from the rack holder. We have employed this method for the determination of equilibrium dissociation constants (Kds) for drugs at the 5 human muscarinic acetylcholine receptor subtypes expressed in cultured cells, as well as histamine H1, dopamine D2, serotonin 5HT1A, alpha 1- and alpha 2-adrenergic receptors in human brain tissue homogenates. Our results compare favorably with manual methods reported for these receptors, and exhibit a very high degree of reproducibility and throughput, with a minimum of operator input.</p>\",\"PeriodicalId\":16948,\"journal\":{\"name\":\"Journal of receptor research\",\"volume\":\"13 1-4\",\"pages\":\"123-34\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1993-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.3109/10799899309073650\",\"citationCount\":\"17\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of receptor research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3109/10799899309073650\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of receptor research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3109/10799899309073650","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 17

摘要

放射配体结合试验为筛选许多受体的候选药物提供了强有力的工具。我们提出了一种利用机器人工作站的方法,Biomek 1000,它自动化了这些检测的繁琐和重复任务。首先,机器人处理多达8种药物的连续稀释,每种药物有11种浓度。顺序添加稀释缓冲液,非放射性标记配体,放射性配体,最后组织匀浆或膜制备,是完全自动化的。新颖的机架设计允许使用最大容量为2毫升的管,提供1毫升的总测定量。配备独特设计的头部的Brandel细胞采集器上的最终过滤允许同时处理来自机架支架的48个样品。我们利用该方法测定了培养细胞中表达的5种人毒毒碱乙酰胆碱受体亚型以及人脑组织匀浆中组胺H1、多巴胺D2、血清素5HT1A、α 1-和α 2-肾上腺素能受体的药物平衡解离常数(Kds)。我们的结果与报道的这些受体的手工方法相比,表现出非常高的再现性和吞吐量,并且具有最小的操作员输入。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A method for radioligand binding assays using a robotic workstation.

Radioligand binding assays provide a powerful tool for screening drug candidates at many receptors. We present a method utilizing a robotic workstation, the Biomek 1000, which automates the tedious and repetitive tasks of these assays. First, the robot handles the serial dilution of up to 8 drugs with 11 concentrations per drug. The sequential addition of diluting buffer, non-radioactively labeled ligand, radioactive ligand, and finally the tissue homogenate or membrane preparation, is fully automated. A novel rack design allows the use of tubes with a maximum capacity of 2 ml, providing a total assay volume of 1 ml. Final filtration on a Brandel cell harvester outfitted with a uniquely designed head allows for processing of 48 samples simultaneously from the rack holder. We have employed this method for the determination of equilibrium dissociation constants (Kds) for drugs at the 5 human muscarinic acetylcholine receptor subtypes expressed in cultured cells, as well as histamine H1, dopamine D2, serotonin 5HT1A, alpha 1- and alpha 2-adrenergic receptors in human brain tissue homogenates. Our results compare favorably with manual methods reported for these receptors, and exhibit a very high degree of reproducibility and throughput, with a minimum of operator input.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信