{"title":"新浓缩汞合金修复体的修复。","authors":"J Bagheri,&nbsp;K C Chan","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>This study investigated the tensile strength of the newly condensed amalgam repaired with newly triturated amalgam in different times. A separable plexiglass mold with a dumbbell shape \"cavity\" was prepared. Amalgam was condensed in the \"cavity\" and allowed to set for one hour before it was removed from the mold and used for control. Five controls were prepared. Five groups with five samples in each group were prepared. Amalgam was condensed in the first half of the \"cavity\" and 5, 15, 30, 60 minutes and 24 hours later newly triturated amalgam was condensed in the second half of the \"cavity\" for the 5, 15, 60 minutes and 24 hour group samples. All samples were allowed to set in the mold for one hour then removed and stored in 100% humidity condition at room temperature for 24 hours. Tensile strength was tested on the Instron testing machine. It was found that when the newly condensed amalgam was repaired in five minutes, it has 84% of the tensile strength and was not significantly different from the controls. When it was repaired in 15, 30, 60 minutes and 24 hours, the tensile strength was significantly lower than the controls and significantly different from the controls.</p>","PeriodicalId":76640,"journal":{"name":"The Iowa dental journal","volume":"79 3","pages":"13-4"},"PeriodicalIF":0.0000,"publicationDate":"1993-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Repair of newly condensed amalgam restorations.\",\"authors\":\"J Bagheri,&nbsp;K C Chan\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>This study investigated the tensile strength of the newly condensed amalgam repaired with newly triturated amalgam in different times. A separable plexiglass mold with a dumbbell shape \\\"cavity\\\" was prepared. Amalgam was condensed in the \\\"cavity\\\" and allowed to set for one hour before it was removed from the mold and used for control. Five controls were prepared. Five groups with five samples in each group were prepared. Amalgam was condensed in the first half of the \\\"cavity\\\" and 5, 15, 30, 60 minutes and 24 hours later newly triturated amalgam was condensed in the second half of the \\\"cavity\\\" for the 5, 15, 60 minutes and 24 hour group samples. All samples were allowed to set in the mold for one hour then removed and stored in 100% humidity condition at room temperature for 24 hours. Tensile strength was tested on the Instron testing machine. It was found that when the newly condensed amalgam was repaired in five minutes, it has 84% of the tensile strength and was not significantly different from the controls. When it was repaired in 15, 30, 60 minutes and 24 hours, the tensile strength was significantly lower than the controls and significantly different from the controls.</p>\",\"PeriodicalId\":76640,\"journal\":{\"name\":\"The Iowa dental journal\",\"volume\":\"79 3\",\"pages\":\"13-4\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1993-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"The Iowa dental journal\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Iowa dental journal","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

研究了不同时间用新软化银汞合金修复后新凝聚银汞合金的抗拉强度。制备了一种具有哑铃形“腔”的可分离有机玻璃模具。汞合金在“空腔”中凝结并凝固一小时,然后从模具中取出并用于控制。准备了5个对照组。5组,每组5个样品。在“空腔”的前半部分浓缩汞合金,在5、15、30、60分钟和24小时后,在“空腔”的后半部分浓缩新磨化的汞合金。所有样品在模具中凝固1小时后取出,在100%湿度的室温条件下保存24小时。在Instron试验机上进行拉伸强度测试。结果发现,在5分钟内修复新凝聚的银汞合金,其抗拉强度提高了84%,与对照无显著差异。在15、30、60分钟和24小时修复时,抗拉强度显著低于对照组,与对照组差异显著。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Repair of newly condensed amalgam restorations.

This study investigated the tensile strength of the newly condensed amalgam repaired with newly triturated amalgam in different times. A separable plexiglass mold with a dumbbell shape "cavity" was prepared. Amalgam was condensed in the "cavity" and allowed to set for one hour before it was removed from the mold and used for control. Five controls were prepared. Five groups with five samples in each group were prepared. Amalgam was condensed in the first half of the "cavity" and 5, 15, 30, 60 minutes and 24 hours later newly triturated amalgam was condensed in the second half of the "cavity" for the 5, 15, 60 minutes and 24 hour group samples. All samples were allowed to set in the mold for one hour then removed and stored in 100% humidity condition at room temperature for 24 hours. Tensile strength was tested on the Instron testing machine. It was found that when the newly condensed amalgam was repaired in five minutes, it has 84% of the tensile strength and was not significantly different from the controls. When it was repaired in 15, 30, 60 minutes and 24 hours, the tensile strength was significantly lower than the controls and significantly different from the controls.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信