水射流解剖在内镜手术中的实验评价。

A Cuschieri
{"title":"水射流解剖在内镜手术中的实验评价。","authors":"A Cuschieri","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>The problems associated with high-velocity high-pressure water-jet dissection were investigated by in-vivo experiments using endoscopic equipment. Three problems were identified: backspray with fouling of the optic, poor control of the depth of cut, and detachment of tissue fragments and isolated cells which contaminate the operative field. The first two problems have been resolved by adoption of a hooded hand-piece and the incorporation of an adjustable back stop. A \"dry\" system which enables the evacuation of the back spray may deal with the problem of contamination of the operative field by detached cells but further in-vivo experiments are needed to confirm this. Until then, water-jet cutting is considered unsafe for both open and endoscopic surgery in patients undergoing extirpative procedures for cancer because of the risk of tumour seeding within the peritoneal cavity.</p>","PeriodicalId":79337,"journal":{"name":"Endoscopic surgery and allied technologies","volume":"2 3-4","pages":"202-4"},"PeriodicalIF":0.0000,"publicationDate":"1994-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Experimental evaluation of water-jet dissection in endoscopic surgery.\",\"authors\":\"A Cuschieri\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The problems associated with high-velocity high-pressure water-jet dissection were investigated by in-vivo experiments using endoscopic equipment. Three problems were identified: backspray with fouling of the optic, poor control of the depth of cut, and detachment of tissue fragments and isolated cells which contaminate the operative field. The first two problems have been resolved by adoption of a hooded hand-piece and the incorporation of an adjustable back stop. A \\\"dry\\\" system which enables the evacuation of the back spray may deal with the problem of contamination of the operative field by detached cells but further in-vivo experiments are needed to confirm this. Until then, water-jet cutting is considered unsafe for both open and endoscopic surgery in patients undergoing extirpative procedures for cancer because of the risk of tumour seeding within the peritoneal cavity.</p>\",\"PeriodicalId\":79337,\"journal\":{\"name\":\"Endoscopic surgery and allied technologies\",\"volume\":\"2 3-4\",\"pages\":\"202-4\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1994-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Endoscopic surgery and allied technologies\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Endoscopic surgery and allied technologies","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

利用内窥镜设备进行体内实验,研究了高速高压水射流解剖的相关问题。我们发现了三个问题:后喷造成的光学污染、切割深度控制不佳、组织碎片和分离细胞脱离污染手术视野。前两个问题已经通过采用一个带帽的手件和一个可调节的后止动装置得到解决。一种“干式”系统可以使后喷液排出,可以解决分离细胞污染手术区域的问题,但需要进一步的体内实验来证实这一点。在此之前,水射流切割被认为是不安全的,无论是在开放手术还是内窥镜手术中,因为肿瘤有在腹腔内播种的风险。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Experimental evaluation of water-jet dissection in endoscopic surgery.

The problems associated with high-velocity high-pressure water-jet dissection were investigated by in-vivo experiments using endoscopic equipment. Three problems were identified: backspray with fouling of the optic, poor control of the depth of cut, and detachment of tissue fragments and isolated cells which contaminate the operative field. The first two problems have been resolved by adoption of a hooded hand-piece and the incorporation of an adjustable back stop. A "dry" system which enables the evacuation of the back spray may deal with the problem of contamination of the operative field by detached cells but further in-vivo experiments are needed to confirm this. Until then, water-jet cutting is considered unsafe for both open and endoscopic surgery in patients undergoing extirpative procedures for cancer because of the risk of tumour seeding within the peritoneal cavity.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信