顺序流动注射法测定唾液中离子钙和总钙。

S Jun, J L Lima, M C Montenegro
{"title":"顺序流动注射法测定唾液中离子钙和总钙。","authors":"S Jun,&nbsp;J L Lima,&nbsp;M C Montenegro","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>In this paper a flow injection manifold for the sequential determination of ionic and total calcium in a small (75 microL) sample of saliva is presented. This setup incorporates two detectors, a tubular potentiometric detector and an atomic absorption spectrophotometer, for determining the ionic and total calcium, respectively. Furthermore, the saliva samples can be injected directly into the manifold without any pre-treatment or loss of carbon dioxide. The results of the analyses of 20 saliva samples were in good agreement with those obtained by the two reference procedures, the direct potentiometry for ionic calcium and atomic absorption spectroscopy for total calcium. The paired Student's t-test showed that there were no statistical differences in the results obtained. The relative standard deviations of ten consecutive measurements of the same salive sample were approximately 3% for ionic calcium and 4% for total calcium. Effects of differences in coexisting ions, ionic strength, and pH between standard solutions and samples were negligible.</p>","PeriodicalId":77233,"journal":{"name":"Journal of trace elements and electrolytes in health and disease","volume":"8 2","pages":"93-8"},"PeriodicalIF":0.0000,"publicationDate":"1994-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Sequential flow-injection determination of ionic and total calcium in saliva.\",\"authors\":\"S Jun,&nbsp;J L Lima,&nbsp;M C Montenegro\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>In this paper a flow injection manifold for the sequential determination of ionic and total calcium in a small (75 microL) sample of saliva is presented. This setup incorporates two detectors, a tubular potentiometric detector and an atomic absorption spectrophotometer, for determining the ionic and total calcium, respectively. Furthermore, the saliva samples can be injected directly into the manifold without any pre-treatment or loss of carbon dioxide. The results of the analyses of 20 saliva samples were in good agreement with those obtained by the two reference procedures, the direct potentiometry for ionic calcium and atomic absorption spectroscopy for total calcium. The paired Student's t-test showed that there were no statistical differences in the results obtained. The relative standard deviations of ten consecutive measurements of the same salive sample were approximately 3% for ionic calcium and 4% for total calcium. Effects of differences in coexisting ions, ionic strength, and pH between standard solutions and samples were negligible.</p>\",\"PeriodicalId\":77233,\"journal\":{\"name\":\"Journal of trace elements and electrolytes in health and disease\",\"volume\":\"8 2\",\"pages\":\"93-8\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1994-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of trace elements and electrolytes in health and disease\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of trace elements and electrolytes in health and disease","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文介绍了一种用于小(75微升)唾液样品中离子钙和总钙的连续测定的流动注射歧管。该装置包括两个检测器,一个管式电位检测器和一个原子吸收分光光度计,分别用于测定离子和总钙。此外,唾液样本可以直接注入歧管,无需任何预处理或二氧化碳损失。20份唾液样品的分析结果与离子钙的直接电位法和总钙的原子吸收光谱法两种参考方法的分析结果吻合较好。配对学生t检验显示,所得结果无统计学差异。对于相同的salive样品,连续十次测量的相对标准偏差离子钙约为3%,总钙约为4%。标准溶液和样品之间共存离子、离子强度和pH值差异的影响可以忽略不计。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Sequential flow-injection determination of ionic and total calcium in saliva.

In this paper a flow injection manifold for the sequential determination of ionic and total calcium in a small (75 microL) sample of saliva is presented. This setup incorporates two detectors, a tubular potentiometric detector and an atomic absorption spectrophotometer, for determining the ionic and total calcium, respectively. Furthermore, the saliva samples can be injected directly into the manifold without any pre-treatment or loss of carbon dioxide. The results of the analyses of 20 saliva samples were in good agreement with those obtained by the two reference procedures, the direct potentiometry for ionic calcium and atomic absorption spectroscopy for total calcium. The paired Student's t-test showed that there were no statistical differences in the results obtained. The relative standard deviations of ten consecutive measurements of the same salive sample were approximately 3% for ionic calcium and 4% for total calcium. Effects of differences in coexisting ions, ionic strength, and pH between standard solutions and samples were negligible.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信