先天性心脏缺损Fontan手术心房肺和腔室肺连接的血流研究

H.T. Low , Y.T. Chew , C.N. Lee
{"title":"先天性心脏缺损Fontan手术心房肺和腔室肺连接的血流研究","authors":"H.T. Low ,&nbsp;Y.T. Chew ,&nbsp;C.N. Lee","doi":"10.1016/0141-5425(93)90006-K","DOIUrl":null,"url":null,"abstract":"<div><p>A comparative flow study has been conducted on two configurations of the Fontan operations for congenital heart defects in which the right ventricle is by-passed. The study was made on rigid <em>in vitro</em> models of the atriopulmonary and cavopulmonary connections under steady-flow conditions. It involved using pressure and flow measurements to determine the pressure-drop coefficient, pressure-energy-loss coefficient and total-energy-loss coefficient. The cavopulmonary model was found to have much lower flow losses compared to the atriopulmonary model, especially at flow rates about 5 l min<sup>−1</sup></p></div>","PeriodicalId":75992,"journal":{"name":"Journal of biomedical engineering","volume":"15 4","pages":"Pages 303-307"},"PeriodicalIF":0.0000,"publicationDate":"1993-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/0141-5425(93)90006-K","citationCount":"53","resultStr":"{\"title\":\"Flow studies on atriopulmonary and cavopulmonary connections of the Fontan operations for congenital heart defects\",\"authors\":\"H.T. Low ,&nbsp;Y.T. Chew ,&nbsp;C.N. Lee\",\"doi\":\"10.1016/0141-5425(93)90006-K\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>A comparative flow study has been conducted on two configurations of the Fontan operations for congenital heart defects in which the right ventricle is by-passed. The study was made on rigid <em>in vitro</em> models of the atriopulmonary and cavopulmonary connections under steady-flow conditions. It involved using pressure and flow measurements to determine the pressure-drop coefficient, pressure-energy-loss coefficient and total-energy-loss coefficient. The cavopulmonary model was found to have much lower flow losses compared to the atriopulmonary model, especially at flow rates about 5 l min<sup>−1</sup></p></div>\",\"PeriodicalId\":75992,\"journal\":{\"name\":\"Journal of biomedical engineering\",\"volume\":\"15 4\",\"pages\":\"Pages 303-307\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1993-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1016/0141-5425(93)90006-K\",\"citationCount\":\"53\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of biomedical engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/014154259390006K\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of biomedical engineering","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/014154259390006K","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 53

摘要

一项比较流量的研究已经进行了两种配置的Fontan手术先天性心脏缺陷,其中右心室旁路。本研究建立了稳定血流条件下心房肺和腔室肺连接的刚性体外模型。它包括使用压力和流量测量来确定压降系数、压力-能量损失系数和总能量损失系数。与心房肺模型相比,腔室肺模型的血流损失要小得多,尤其是在流速约为51min−1时
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Flow studies on atriopulmonary and cavopulmonary connections of the Fontan operations for congenital heart defects

A comparative flow study has been conducted on two configurations of the Fontan operations for congenital heart defects in which the right ventricle is by-passed. The study was made on rigid in vitro models of the atriopulmonary and cavopulmonary connections under steady-flow conditions. It involved using pressure and flow measurements to determine the pressure-drop coefficient, pressure-energy-loss coefficient and total-energy-loss coefficient. The cavopulmonary model was found to have much lower flow losses compared to the atriopulmonary model, especially at flow rates about 5 l min−1

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信