{"title":"血浆和尿液中金属硫蛋白-1酶联免疫吸附测定方法的建立。","authors":"D F Akintola, B Sampson, A Fleck","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>The development of a sensitive enzyme-linked immunosorbent assay (ELISA) for human metallothionein-1 is reported. Metallothionein was purified from postmortem human liver and used to raise high-titer antibodies in rabbits. The assay was specific for human metallothionein-1 (MT-1), and there was no significant cross-reaction with human metallothionein-2. The detection limit (sensitivity) of the assay was 5 ng/ml, and the added MT-1 could be fully recovered from plasma and urine. The normal reference range for MT-1 was 32 +/- 16 ng/ml in plasma and 10 +/- 6 ng MT-1 per micromole of creatinine in random samples of urine. No significant differences were found between the values for males and females. The concentration of MT-1 was greatly increased between 24 and 48 hours after surgery, indicating that the protein behaves like an acute phase reactant in human subjects.</p>","PeriodicalId":23085,"journal":{"name":"The Journal of laboratory and clinical medicine","volume":"126 2","pages":"119-27"},"PeriodicalIF":0.0000,"publicationDate":"1995-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Development of an enzyme-linked immunosorbent assay for human metallothionein-1 in plasma and urine.\",\"authors\":\"D F Akintola, B Sampson, A Fleck\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The development of a sensitive enzyme-linked immunosorbent assay (ELISA) for human metallothionein-1 is reported. Metallothionein was purified from postmortem human liver and used to raise high-titer antibodies in rabbits. The assay was specific for human metallothionein-1 (MT-1), and there was no significant cross-reaction with human metallothionein-2. The detection limit (sensitivity) of the assay was 5 ng/ml, and the added MT-1 could be fully recovered from plasma and urine. The normal reference range for MT-1 was 32 +/- 16 ng/ml in plasma and 10 +/- 6 ng MT-1 per micromole of creatinine in random samples of urine. No significant differences were found between the values for males and females. The concentration of MT-1 was greatly increased between 24 and 48 hours after surgery, indicating that the protein behaves like an acute phase reactant in human subjects.</p>\",\"PeriodicalId\":23085,\"journal\":{\"name\":\"The Journal of laboratory and clinical medicine\",\"volume\":\"126 2\",\"pages\":\"119-27\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1995-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"The Journal of laboratory and clinical medicine\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Journal of laboratory and clinical medicine","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Development of an enzyme-linked immunosorbent assay for human metallothionein-1 in plasma and urine.
The development of a sensitive enzyme-linked immunosorbent assay (ELISA) for human metallothionein-1 is reported. Metallothionein was purified from postmortem human liver and used to raise high-titer antibodies in rabbits. The assay was specific for human metallothionein-1 (MT-1), and there was no significant cross-reaction with human metallothionein-2. The detection limit (sensitivity) of the assay was 5 ng/ml, and the added MT-1 could be fully recovered from plasma and urine. The normal reference range for MT-1 was 32 +/- 16 ng/ml in plasma and 10 +/- 6 ng MT-1 per micromole of creatinine in random samples of urine. No significant differences were found between the values for males and females. The concentration of MT-1 was greatly increased between 24 and 48 hours after surgery, indicating that the protein behaves like an acute phase reactant in human subjects.