用阻抗容积描记仪自动测定心输出量。

Biotelemetry and patient monitoring Pub Date : 1981-01-01
Y Miyamoto, T Tamura, T Mikami
{"title":"用阻抗容积描记仪自动测定心输出量。","authors":"Y Miyamoto,&nbsp;T Tamura,&nbsp;T Mikami","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>A computer-based system which calculates stroke volume, heart rate and cardiac output automatically from the transthoracic impedance variation has been developed. A beat-by-beat determination was performed on several healthy subjects and patients with atrial fibrillation during spontaneous breathings at rest. The respiratory artifact appearing on the impedance cardiogram was canceled by (1) correcting the base line of dZ/dt for each cardiac cycle on the basis of assumption that the dZ/dt values at ECG-R waves would be invariable regardless of the respiratory phase when the respiratory movement ceases, and (2) averaging the signals for a number of cardiac cycles. Comparisons between the computed stroke volumes and those obtained from a manual calculation showed good agreement.</p>","PeriodicalId":75603,"journal":{"name":"Biotelemetry and patient monitoring","volume":"8 4","pages":"189-203"},"PeriodicalIF":0.0000,"publicationDate":"1981-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Automatic determination of cardiac output using an impedance plethysmography.\",\"authors\":\"Y Miyamoto,&nbsp;T Tamura,&nbsp;T Mikami\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>A computer-based system which calculates stroke volume, heart rate and cardiac output automatically from the transthoracic impedance variation has been developed. A beat-by-beat determination was performed on several healthy subjects and patients with atrial fibrillation during spontaneous breathings at rest. The respiratory artifact appearing on the impedance cardiogram was canceled by (1) correcting the base line of dZ/dt for each cardiac cycle on the basis of assumption that the dZ/dt values at ECG-R waves would be invariable regardless of the respiratory phase when the respiratory movement ceases, and (2) averaging the signals for a number of cardiac cycles. Comparisons between the computed stroke volumes and those obtained from a manual calculation showed good agreement.</p>\",\"PeriodicalId\":75603,\"journal\":{\"name\":\"Biotelemetry and patient monitoring\",\"volume\":\"8 4\",\"pages\":\"189-203\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1981-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Biotelemetry and patient monitoring\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biotelemetry and patient monitoring","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

开发了一种基于计算机的系统,可以根据经胸阻抗变化自动计算出搏量、心率和心输出量。对几名健康受试者和房颤患者在休息时的自发呼吸进行了逐次测定。通过以下方法消除了阻抗心电图上出现的呼吸伪影:(1)在假设呼吸运动停止时,ECG-R波的dZ/dt值无论呼吸期如何都是不变的基础上,修正了每个心动周期的dZ/dt基线;(2)对多个心动周期的信号进行平均。计算出的冲程体积与人工计算得到的冲程体积之间的比较显示出良好的一致性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Automatic determination of cardiac output using an impedance plethysmography.

A computer-based system which calculates stroke volume, heart rate and cardiac output automatically from the transthoracic impedance variation has been developed. A beat-by-beat determination was performed on several healthy subjects and patients with atrial fibrillation during spontaneous breathings at rest. The respiratory artifact appearing on the impedance cardiogram was canceled by (1) correcting the base line of dZ/dt for each cardiac cycle on the basis of assumption that the dZ/dt values at ECG-R waves would be invariable regardless of the respiratory phase when the respiratory movement ceases, and (2) averaging the signals for a number of cardiac cycles. Comparisons between the computed stroke volumes and those obtained from a manual calculation showed good agreement.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信