{"title":"使用碲化镉探测器进行放射性核素局部清除研究中的生物遥测。","authors":"J Bojsen, B Staberg, K Kølendorf","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Small, gamma-sensitive, cadmium-telluride [CdTe(C1)] detectors are evaluated for biotelemetry of the local clearance of an injected radioactive depot in tissue. The lateral displacement dependence and depth dependence are determined with 99mTc as radiation source. Perspex is used as attenuation and scattering medium. With 133Xe injected into subcutaneous tissue the effect of a geometrical adjustment of the CdTe(C1) detector prior to measurement is studied. Examples of 133Xe disappearance curves are shown during rest and ergometry bicycling.</p>","PeriodicalId":75603,"journal":{"name":"Biotelemetry and patient monitoring","volume":"9 3","pages":"144-53"},"PeriodicalIF":0.0000,"publicationDate":"1982-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Biotelemetry in local clearance studies with radionuclides using cadmium telluride detectors.\",\"authors\":\"J Bojsen, B Staberg, K Kølendorf\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Small, gamma-sensitive, cadmium-telluride [CdTe(C1)] detectors are evaluated for biotelemetry of the local clearance of an injected radioactive depot in tissue. The lateral displacement dependence and depth dependence are determined with 99mTc as radiation source. Perspex is used as attenuation and scattering medium. With 133Xe injected into subcutaneous tissue the effect of a geometrical adjustment of the CdTe(C1) detector prior to measurement is studied. Examples of 133Xe disappearance curves are shown during rest and ergometry bicycling.</p>\",\"PeriodicalId\":75603,\"journal\":{\"name\":\"Biotelemetry and patient monitoring\",\"volume\":\"9 3\",\"pages\":\"144-53\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1982-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Biotelemetry and patient monitoring\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biotelemetry and patient monitoring","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Biotelemetry in local clearance studies with radionuclides using cadmium telluride detectors.
Small, gamma-sensitive, cadmium-telluride [CdTe(C1)] detectors are evaluated for biotelemetry of the local clearance of an injected radioactive depot in tissue. The lateral displacement dependence and depth dependence are determined with 99mTc as radiation source. Perspex is used as attenuation and scattering medium. With 133Xe injected into subcutaneous tissue the effect of a geometrical adjustment of the CdTe(C1) detector prior to measurement is studied. Examples of 133Xe disappearance curves are shown during rest and ergometry bicycling.