氙-133对局部脑血流的研究。动脉内注射研究和吸入研究使用放射断层扫描。

N A Lassen
{"title":"氙-133对局部脑血流的研究。动脉内注射研究和吸入研究使用放射断层扫描。","authors":"N A Lassen","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>A survey of the Xenon-133 techniques for measurement of regional cerebral blood flow, rCBF, in man is presented. The intra-arterial Xe-133 injection method is very sensitive for detecting even small hyperemic areas, but cannot \"see\" smaller ischemic areas. The Xe-133 inhalation (or i.v. inj.) technique is insensitive both to hyperemia and ischemia yielding essentially only a mean flow value. A new rapidly moving single photon tomograph following D. Kuhl's principle is presented applicable to Xe-133. Preliminary clinical data show that this technique is able to detect ischemic areas both with Xe-133 intra-arterial injection and with Xe-133 inhalation. The practical and economic advantages of Xe-133 or Xe-127 tomography over positron tomography for rCBF are discussed.</p>","PeriodicalId":75639,"journal":{"name":"Bulletin der Schweizerischen Akademie der Medizinischen Wissenschaften","volume":"36 1-3","pages":"93-100"},"PeriodicalIF":0.0000,"publicationDate":"1980-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Regional cerebral blod flow studied by xenon-133. Intra-arterial injection studies and inhalation studies using emission tomography.\",\"authors\":\"N A Lassen\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>A survey of the Xenon-133 techniques for measurement of regional cerebral blood flow, rCBF, in man is presented. The intra-arterial Xe-133 injection method is very sensitive for detecting even small hyperemic areas, but cannot \\\"see\\\" smaller ischemic areas. The Xe-133 inhalation (or i.v. inj.) technique is insensitive both to hyperemia and ischemia yielding essentially only a mean flow value. A new rapidly moving single photon tomograph following D. Kuhl's principle is presented applicable to Xe-133. Preliminary clinical data show that this technique is able to detect ischemic areas both with Xe-133 intra-arterial injection and with Xe-133 inhalation. The practical and economic advantages of Xe-133 or Xe-127 tomography over positron tomography for rCBF are discussed.</p>\",\"PeriodicalId\":75639,\"journal\":{\"name\":\"Bulletin der Schweizerischen Akademie der Medizinischen Wissenschaften\",\"volume\":\"36 1-3\",\"pages\":\"93-100\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1980-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Bulletin der Schweizerischen Akademie der Medizinischen Wissenschaften\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Bulletin der Schweizerischen Akademie der Medizinischen Wissenschaften","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

一项调查氙-133技术测量区域脑血流,rCBF,在人提出。动脉内注射Xe-133法对检测小的充血区域非常敏感,但不能“看到”更小的缺血区域。Xe-133吸入(或静脉注射)技术对充血和缺血都不敏感,基本上只产生平均流量值。提出了一种适用于Xe-133的基于库尔原理的快速移动单光子层析成像方法。初步临床数据表明,该技术能够检测缺血区域,无论是动脉注射和吸入的Xe-133。讨论了在rCBF中使用正电子层析成像技术相比于使用正电子层析成像技术的实用性和经济性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Regional cerebral blod flow studied by xenon-133. Intra-arterial injection studies and inhalation studies using emission tomography.

A survey of the Xenon-133 techniques for measurement of regional cerebral blood flow, rCBF, in man is presented. The intra-arterial Xe-133 injection method is very sensitive for detecting even small hyperemic areas, but cannot "see" smaller ischemic areas. The Xe-133 inhalation (or i.v. inj.) technique is insensitive both to hyperemia and ischemia yielding essentially only a mean flow value. A new rapidly moving single photon tomograph following D. Kuhl's principle is presented applicable to Xe-133. Preliminary clinical data show that this technique is able to detect ischemic areas both with Xe-133 intra-arterial injection and with Xe-133 inhalation. The practical and economic advantages of Xe-133 or Xe-127 tomography over positron tomography for rCBF are discussed.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信