{"title":"[用高效液相色谱法测定牙科用甲基丙烯酸酯、引发剂和其他化合物的疏水参数(log PHPLC)[作者简介]。","authors":"S Fujisawa,&nbsp;E Masuhara","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>The use of partition coefficients Poct obtained from an n-octanol-water partitioning system has become a standard method for modelling biological membranes and thereby quantifying the hydrophobicity of a given compound as log Poct = log Coct--log Cwater. However, there is no convenient method available to determine the log Poct value accurately. The conventional flask-shaking method is a laborious and time consuming procedure, often complicated by instability in aqueous media, impurities and the tendency for the compound to dissociate. There have been recently attempts using HPLC to determine the hydrophobicity of organic compound. The retention behaviour of about fifty organic compounds in HPLC systems have been examined. Using methanol-water as the mobile phase, a linear relationship between the volume fraction of organic modifier and the logarithm of the capacity factor (log K') over limited range was obtained for standards. However, unfortunately, the correlation between log Kw obtained from the extrapolated K' values with pure water as eluent and log Poct values was not good (r = 0.83). Using this octadecylsilyl column with the mobile phase (methanol: water = 70:30), standards fall on the three straight lines with good correlations (r = 0.99) between the log Poct and log K' values.: one for benzenes and aliphatic compounds, the second for phenols, anilines and hydrogenacceptor benzene derivatives and the third for benzoic acids, respectively. The PHPLC values of methacrylates, initiators and miscellaneous compounds which are widely in dentistry were determined using these three regression lines.</p>","PeriodicalId":76541,"journal":{"name":"Shika rikogaku zasshi. Journal of the Japan Society for Dental Apparatus and Materials","volume":"22 60","pages":"277-84"},"PeriodicalIF":0.0000,"publicationDate":"1981-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"[Determination of hydrophobic parameters (log PHPLC) for methacrylates, initiators and miscellaneous compounds used in dentistry by high-performance liquid chromatography (HPLC) (author's transl)].\",\"authors\":\"S Fujisawa,&nbsp;E Masuhara\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The use of partition coefficients Poct obtained from an n-octanol-water partitioning system has become a standard method for modelling biological membranes and thereby quantifying the hydrophobicity of a given compound as log Poct = log Coct--log Cwater. However, there is no convenient method available to determine the log Poct value accurately. The conventional flask-shaking method is a laborious and time consuming procedure, often complicated by instability in aqueous media, impurities and the tendency for the compound to dissociate. There have been recently attempts using HPLC to determine the hydrophobicity of organic compound. The retention behaviour of about fifty organic compounds in HPLC systems have been examined. Using methanol-water as the mobile phase, a linear relationship between the volume fraction of organic modifier and the logarithm of the capacity factor (log K') over limited range was obtained for standards. However, unfortunately, the correlation between log Kw obtained from the extrapolated K' values with pure water as eluent and log Poct values was not good (r = 0.83). Using this octadecylsilyl column with the mobile phase (methanol: water = 70:30), standards fall on the three straight lines with good correlations (r = 0.99) between the log Poct and log K' values.: one for benzenes and aliphatic compounds, the second for phenols, anilines and hydrogenacceptor benzene derivatives and the third for benzoic acids, respectively. The PHPLC values of methacrylates, initiators and miscellaneous compounds which are widely in dentistry were determined using these three regression lines.</p>\",\"PeriodicalId\":76541,\"journal\":{\"name\":\"Shika rikogaku zasshi. Journal of the Japan Society for Dental Apparatus and Materials\",\"volume\":\"22 60\",\"pages\":\"277-84\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1981-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Shika rikogaku zasshi. Journal of the Japan Society for Dental Apparatus and Materials\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Shika rikogaku zasshi. Journal of the Japan Society for Dental Apparatus and Materials","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

使用从正辛醇-水分配体系中获得的分配系数Poct已经成为模拟生物膜的标准方法,从而量化给定化合物的疏水性:log Poct = log Coct- log Cwater。然而,目前还没有一种简便的方法可以准确地确定日志Poct值。传统的摇瓶法是一个费力而耗时的过程,通常由于水介质的不稳定性、杂质和化合物解离的倾向而变得复杂。最近有人尝试用高效液相色谱法测定有机化合物的疏水性。研究了大约50种有机化合物在高效液相色谱体系中的保留行为。以甲醇-水为流动相,在一定范围内得到了有机改性剂体积分数与容量因子对数(log K′)的线性关系。然而,不幸的是,从以纯水为淋洗剂的外推K'值获得的log Kw与log Poct值之间的相关性并不好(r = 0.83)。使用十八烷基硅基色谱柱和流动相(甲醇:水= 70:30),标准品落在三条直线上,对数Poct和对数K′值之间具有良好的相关性(r = 0.99)。第一个为苯类和脂肪族化合物,第二个为酚类、苯胺类和苯的氢受体衍生物,第三个为苯甲酸。用这三条回归线测定了牙科中广泛使用的甲基丙烯酸酯、引发剂和其他化合物的PHPLC值。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
[Determination of hydrophobic parameters (log PHPLC) for methacrylates, initiators and miscellaneous compounds used in dentistry by high-performance liquid chromatography (HPLC) (author's transl)].

The use of partition coefficients Poct obtained from an n-octanol-water partitioning system has become a standard method for modelling biological membranes and thereby quantifying the hydrophobicity of a given compound as log Poct = log Coct--log Cwater. However, there is no convenient method available to determine the log Poct value accurately. The conventional flask-shaking method is a laborious and time consuming procedure, often complicated by instability in aqueous media, impurities and the tendency for the compound to dissociate. There have been recently attempts using HPLC to determine the hydrophobicity of organic compound. The retention behaviour of about fifty organic compounds in HPLC systems have been examined. Using methanol-water as the mobile phase, a linear relationship between the volume fraction of organic modifier and the logarithm of the capacity factor (log K') over limited range was obtained for standards. However, unfortunately, the correlation between log Kw obtained from the extrapolated K' values with pure water as eluent and log Poct values was not good (r = 0.83). Using this octadecylsilyl column with the mobile phase (methanol: water = 70:30), standards fall on the three straight lines with good correlations (r = 0.99) between the log Poct and log K' values.: one for benzenes and aliphatic compounds, the second for phenols, anilines and hydrogenacceptor benzene derivatives and the third for benzoic acids, respectively. The PHPLC values of methacrylates, initiators and miscellaneous compounds which are widely in dentistry were determined using these three regression lines.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信