{"title":"合金在高温下的流动性。(第二部分)20% Au-Ag-Pd-Cu合金的流动性[作者简介]。","authors":"H Inaba","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>The flow length of 20% Au-Ag-Pd-Cu alloy in the mold heated up to 650 degrees C was measured by the apparatus reported in the previous paper with partial improvement added. The results were summarized as follows. (1) The flow length of Au-Ag-Pd-Cu alloy containing 20% Au in the mold heated up to 650 degrees C increased as the content of Cu increased in the range of 10-20% Pd; however, in the range of more than 22% Pd, it decreased as the content of Pd increased. (2) The maximum flow length was obtained around the composition of 20 Au-40 Ag-15 Pd-25 Cu. On the other hand the minimum flow length was obtained around the composition of 20 Au-65 Ag-10 Pd-5 Cu. (3) There was no correlation between the flow length and both of the melting point and the melting range solidifying area.</p>","PeriodicalId":76541,"journal":{"name":"Shika rikogaku zasshi. Journal of the Japan Society for Dental Apparatus and Materials","volume":"22 57","pages":"45-50"},"PeriodicalIF":0.0000,"publicationDate":"1981-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"[The fluidity of alloys in high temperature. (Part 2) The fluidity of 20% Au-Ag-Pd-Cu alloy (author's transl)].\",\"authors\":\"H Inaba\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The flow length of 20% Au-Ag-Pd-Cu alloy in the mold heated up to 650 degrees C was measured by the apparatus reported in the previous paper with partial improvement added. The results were summarized as follows. (1) The flow length of Au-Ag-Pd-Cu alloy containing 20% Au in the mold heated up to 650 degrees C increased as the content of Cu increased in the range of 10-20% Pd; however, in the range of more than 22% Pd, it decreased as the content of Pd increased. (2) The maximum flow length was obtained around the composition of 20 Au-40 Ag-15 Pd-25 Cu. On the other hand the minimum flow length was obtained around the composition of 20 Au-65 Ag-10 Pd-5 Cu. (3) There was no correlation between the flow length and both of the melting point and the melting range solidifying area.</p>\",\"PeriodicalId\":76541,\"journal\":{\"name\":\"Shika rikogaku zasshi. Journal of the Japan Society for Dental Apparatus and Materials\",\"volume\":\"22 57\",\"pages\":\"45-50\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1981-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Shika rikogaku zasshi. Journal of the Japan Society for Dental Apparatus and Materials\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Shika rikogaku zasshi. Journal of the Japan Society for Dental Apparatus and Materials","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
[The fluidity of alloys in high temperature. (Part 2) The fluidity of 20% Au-Ag-Pd-Cu alloy (author's transl)].
The flow length of 20% Au-Ag-Pd-Cu alloy in the mold heated up to 650 degrees C was measured by the apparatus reported in the previous paper with partial improvement added. The results were summarized as follows. (1) The flow length of Au-Ag-Pd-Cu alloy containing 20% Au in the mold heated up to 650 degrees C increased as the content of Cu increased in the range of 10-20% Pd; however, in the range of more than 22% Pd, it decreased as the content of Pd increased. (2) The maximum flow length was obtained around the composition of 20 Au-40 Ag-15 Pd-25 Cu. On the other hand the minimum flow length was obtained around the composition of 20 Au-65 Ag-10 Pd-5 Cu. (3) There was no correlation between the flow length and both of the melting point and the melting range solidifying area.