{"title":"合金在高温下的流动性。(第1部分)高温流动性测试仪[作者简介]。","authors":"H Inaba","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>The method and apparatus for testing the fluidity of molten alloy in the mold of high temperature as far as about 650 degrees C were designed and the fluidity of pure Ag and Ag-Cu alloy were measured. The results were summarized as follows. (1) The flow length (y mm) of pure Ag increased as the degree of superheat (B degree C) watch with casting temperature minus melting point and the temperature of mold (A degree C) increased. Estimating the formula for the flow length y, it was found that y was represented by the sum of the first order formula of A and B. (2) The flow length of Ag-Cu alloy took large value when the mold with heated up to 650 degrees C. Estimating the formula for the flow length y, it was found that y was represented by the sum of the third order formula of A and the first order formula of B and the formula of the product of A and B.</p>","PeriodicalId":76541,"journal":{"name":"Shika rikogaku zasshi. Journal of the Japan Society for Dental Apparatus and Materials","volume":"22 57","pages":"37-44"},"PeriodicalIF":0.0000,"publicationDate":"1981-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"[The fluidity of alloys in high temperature. (Part 1) Testing apparatus of fluidity in high temperature (author's transl)].\",\"authors\":\"H Inaba\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The method and apparatus for testing the fluidity of molten alloy in the mold of high temperature as far as about 650 degrees C were designed and the fluidity of pure Ag and Ag-Cu alloy were measured. The results were summarized as follows. (1) The flow length (y mm) of pure Ag increased as the degree of superheat (B degree C) watch with casting temperature minus melting point and the temperature of mold (A degree C) increased. Estimating the formula for the flow length y, it was found that y was represented by the sum of the first order formula of A and B. (2) The flow length of Ag-Cu alloy took large value when the mold with heated up to 650 degrees C. Estimating the formula for the flow length y, it was found that y was represented by the sum of the third order formula of A and the first order formula of B and the formula of the product of A and B.</p>\",\"PeriodicalId\":76541,\"journal\":{\"name\":\"Shika rikogaku zasshi. Journal of the Japan Society for Dental Apparatus and Materials\",\"volume\":\"22 57\",\"pages\":\"37-44\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1981-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Shika rikogaku zasshi. Journal of the Japan Society for Dental Apparatus and Materials\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Shika rikogaku zasshi. Journal of the Japan Society for Dental Apparatus and Materials","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

设计了在高达650℃的高温结晶器中测试合金液流动性的方法和装置,并对纯银和银铜合金的流动性进行了测试。结果总结如下:(1)纯银的流动长度(y mm)随着过热度(B度C)的增加而增加,浇注温度为零下熔点的手表和模具温度(A度C)增加。估计流长度的公式y,发现y代表是之和A和B的一阶公式(2)的流动长度Ag-Cu合金带着较大的值,当模具加热到650度c估算流长度的公式y,发现y代表是之和的三阶公式A和B的一阶公式和公式的A和B的产物。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
[The fluidity of alloys in high temperature. (Part 1) Testing apparatus of fluidity in high temperature (author's transl)].

The method and apparatus for testing the fluidity of molten alloy in the mold of high temperature as far as about 650 degrees C were designed and the fluidity of pure Ag and Ag-Cu alloy were measured. The results were summarized as follows. (1) The flow length (y mm) of pure Ag increased as the degree of superheat (B degree C) watch with casting temperature minus melting point and the temperature of mold (A degree C) increased. Estimating the formula for the flow length y, it was found that y was represented by the sum of the first order formula of A and B. (2) The flow length of Ag-Cu alloy took large value when the mold with heated up to 650 degrees C. Estimating the formula for the flow length y, it was found that y was represented by the sum of the third order formula of A and the first order formula of B and the formula of the product of A and B.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信