强相通道二分法和克罗泽定律。

C R Ingling, E Martinez, A L Lewis
{"title":"强相通道二分法和克罗泽定律。","authors":"C R Ingling,&nbsp;E Martinez,&nbsp;A L Lewis","doi":"10.1364/josa.73.000183","DOIUrl":null,"url":null,"abstract":"<p><p>The constancy of the dynamic range in a luminance-discrimination task is known as Crozier's law; an old rule says that about half of a log unit spans the range from a low to a high frequency of seeing. For our conditions the slope of the psychometric function is steeper for short than for long test flashes; Crozier's law requires a different constant when temporal parameters change. This result is substantiated by an analysis of Massof's data [Vision Res. 21,995 (1981)] on the variation of the slope of psychometric curves for different wavelengths. The change in Crozier's constant between conditions may reflect the presence of more than one detection channel. If short test flashes are detected by phasic channels and long test flashes by both phasic and tonic channels, then our result implies a shorter dynamic range for phasic (Y-cell) than for tonic (X-cell) channels.</p>","PeriodicalId":17413,"journal":{"name":"Journal of the Optical Society of America","volume":"73 2","pages":"183-9"},"PeriodicalIF":0.0000,"publicationDate":"1983-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1364/josa.73.000183","citationCount":"15","resultStr":"{\"title\":\"Tonic-phasic-channel dichotomy and Crozier's law.\",\"authors\":\"C R Ingling,&nbsp;E Martinez,&nbsp;A L Lewis\",\"doi\":\"10.1364/josa.73.000183\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The constancy of the dynamic range in a luminance-discrimination task is known as Crozier's law; an old rule says that about half of a log unit spans the range from a low to a high frequency of seeing. For our conditions the slope of the psychometric function is steeper for short than for long test flashes; Crozier's law requires a different constant when temporal parameters change. This result is substantiated by an analysis of Massof's data [Vision Res. 21,995 (1981)] on the variation of the slope of psychometric curves for different wavelengths. The change in Crozier's constant between conditions may reflect the presence of more than one detection channel. If short test flashes are detected by phasic channels and long test flashes by both phasic and tonic channels, then our result implies a shorter dynamic range for phasic (Y-cell) than for tonic (X-cell) channels.</p>\",\"PeriodicalId\":17413,\"journal\":{\"name\":\"Journal of the Optical Society of America\",\"volume\":\"73 2\",\"pages\":\"183-9\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1983-02-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1364/josa.73.000183\",\"citationCount\":\"15\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of the Optical Society of America\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1364/josa.73.000183\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the Optical Society of America","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1364/josa.73.000183","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 15

摘要

在亮度识别任务的动态范围的常数被称为克罗泽定律;一个古老的规则说,大约一半的log单位跨越了从低到高的看到频率的范围。在我们的条件下,心理测量函数的斜率在短时间内比在长时间内更陡;当时间参数改变时,克罗泽定律要求一个不同的常数。这一结果被Massof关于不同波长下心理测量曲线斜率变化的数据[Vision Res. 21995(1981)]的分析所证实。克罗齐尔常数在不同条件下的变化可能反映了多个检测通道的存在。如果相位通道检测到短暂的测试闪光,而相位通道和张力通道同时检测到长时间的测试闪光,那么我们的结果表明,相位(y细胞)通道的动态范围比张力(x细胞)通道的动态范围短。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Tonic-phasic-channel dichotomy and Crozier's law.

The constancy of the dynamic range in a luminance-discrimination task is known as Crozier's law; an old rule says that about half of a log unit spans the range from a low to a high frequency of seeing. For our conditions the slope of the psychometric function is steeper for short than for long test flashes; Crozier's law requires a different constant when temporal parameters change. This result is substantiated by an analysis of Massof's data [Vision Res. 21,995 (1981)] on the variation of the slope of psychometric curves for different wavelengths. The change in Crozier's constant between conditions may reflect the presence of more than one detection channel. If short test flashes are detected by phasic channels and long test flashes by both phasic and tonic channels, then our result implies a shorter dynamic range for phasic (Y-cell) than for tonic (X-cell) channels.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊介绍: OSA was published by The Optical Society from January 1917 to December 1983 before dividing into JOSA A: Optics and Image Science and JOSA B: Optical Physics in 1984.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信