经皮PO2监测在新生儿常规观察中的应用。

Biotelemetry and patient monitoring Pub Date : 1982-01-01
S Maigaard, J G Klebe, F V Kristiansen
{"title":"经皮PO2监测在新生儿常规观察中的应用。","authors":"S Maigaard,&nbsp;J G Klebe,&nbsp;F V Kristiansen","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>TcPO2 was monitored in 209 of 814 infants admitted to the premature ward connected to our obstetric department. The majority of the infants were monitored less than 14 h. Approximately 77% of the infants were treated with up to 40% O2, while for a period the remaining infants were treated with more than 40% O2. TcPO2 values were generally controlled to the desirable range of 7-12 kPa (50-90 mm Hg). The daily handling of the equipment was performed by the nursing staff, who found good correlation between the TcPO2 measurement and clinical observations. The importance of application of the electrode in the preductal area is stressed to avoid hyperoxemia in the retinal vessels.</p>","PeriodicalId":75603,"journal":{"name":"Biotelemetry and patient monitoring","volume":"9 1","pages":"36-44"},"PeriodicalIF":0.0000,"publicationDate":"1982-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Transcutaneous PO2 monitoring in routine observation of newborns.\",\"authors\":\"S Maigaard,&nbsp;J G Klebe,&nbsp;F V Kristiansen\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>TcPO2 was monitored in 209 of 814 infants admitted to the premature ward connected to our obstetric department. The majority of the infants were monitored less than 14 h. Approximately 77% of the infants were treated with up to 40% O2, while for a period the remaining infants were treated with more than 40% O2. TcPO2 values were generally controlled to the desirable range of 7-12 kPa (50-90 mm Hg). The daily handling of the equipment was performed by the nursing staff, who found good correlation between the TcPO2 measurement and clinical observations. The importance of application of the electrode in the preductal area is stressed to avoid hyperoxemia in the retinal vessels.</p>\",\"PeriodicalId\":75603,\"journal\":{\"name\":\"Biotelemetry and patient monitoring\",\"volume\":\"9 1\",\"pages\":\"36-44\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1982-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Biotelemetry and patient monitoring\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biotelemetry and patient monitoring","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

我们对814名早产儿中的209名进行了TcPO2监测。大多数婴儿的监测时间少于14小时。大约77%的婴儿接受高达40%的氧气治疗,而其余婴儿接受超过40%的氧气治疗一段时间。TcPO2值通常控制在7-12 kPa (50-90 mm Hg)的理想范围内。仪器的日常操作由护理人员完成,护理人员发现TcPO2测量值与临床观察结果有良好的相关性。强调了电极在生产区域应用的重要性,以避免视网膜血管中的高氧血症。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Transcutaneous PO2 monitoring in routine observation of newborns.

TcPO2 was monitored in 209 of 814 infants admitted to the premature ward connected to our obstetric department. The majority of the infants were monitored less than 14 h. Approximately 77% of the infants were treated with up to 40% O2, while for a period the remaining infants were treated with more than 40% O2. TcPO2 values were generally controlled to the desirable range of 7-12 kPa (50-90 mm Hg). The daily handling of the equipment was performed by the nursing staff, who found good correlation between the TcPO2 measurement and clinical observations. The importance of application of the electrode in the preductal area is stressed to avoid hyperoxemia in the retinal vessels.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信