{"title":"红细胞-红细胞分解仪(HEDA)。","authors":"H Kiesewetter, C Mrowietz, H Lazar, F Jung","doi":"10.3233/bir-1984-23s136","DOIUrl":null,"url":null,"abstract":"<p><p>We have developed a device for the determination of the minimum shear force necessary to maintain complete disaggregation of erythrocytes and to simultaneously determine the hematocrit of blood samples (red cells in autologous plasma). A functional relationship between this shear force and the hematocrit was determined. The first derivative of the (measured) gamma Tmin as a function of the hematocrit was found to be identical (within limits) for all normal blood samples tested.</p>","PeriodicalId":79205,"journal":{"name":"Biorheology. Supplement : the official journal of the International Society of Biorheology","volume":"1 ","pages":"213-5"},"PeriodicalIF":0.0000,"publicationDate":"1984-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.3233/bir-1984-23s136","citationCount":"2","resultStr":"{\"title\":\"The hematocrit-erythrocyte-disaggregation-apparatus (HEDA).\",\"authors\":\"H Kiesewetter, C Mrowietz, H Lazar, F Jung\",\"doi\":\"10.3233/bir-1984-23s136\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>We have developed a device for the determination of the minimum shear force necessary to maintain complete disaggregation of erythrocytes and to simultaneously determine the hematocrit of blood samples (red cells in autologous plasma). A functional relationship between this shear force and the hematocrit was determined. The first derivative of the (measured) gamma Tmin as a function of the hematocrit was found to be identical (within limits) for all normal blood samples tested.</p>\",\"PeriodicalId\":79205,\"journal\":{\"name\":\"Biorheology. Supplement : the official journal of the International Society of Biorheology\",\"volume\":\"1 \",\"pages\":\"213-5\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1984-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.3233/bir-1984-23s136\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Biorheology. Supplement : the official journal of the International Society of Biorheology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3233/bir-1984-23s136\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biorheology. Supplement : the official journal of the International Society of Biorheology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3233/bir-1984-23s136","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
The hematocrit-erythrocyte-disaggregation-apparatus (HEDA).
We have developed a device for the determination of the minimum shear force necessary to maintain complete disaggregation of erythrocytes and to simultaneously determine the hematocrit of blood samples (red cells in autologous plasma). A functional relationship between this shear force and the hematocrit was determined. The first derivative of the (measured) gamma Tmin as a function of the hematocrit was found to be identical (within limits) for all normal blood samples tested.