微波法测定肺水变化。

M F Iskander, C H Durney
{"title":"微波法测定肺水变化。","authors":"M F Iskander,&nbsp;C H Durney","doi":"10.1080/16070658.1983.11689331","DOIUrl":null,"url":null,"abstract":"<p><p>Two microwave methods for measuring changes in lung water content have been investigated. The first is based on measuring changes in the phase of an active microwave signal transmitted through the thorax, while the other is based on measuring the natural microwave radiation emitted by the body with a radiometer. The feasibility of using the active microwave method is investigated by making measurements on phantoms, on anesthetized dogs with induced pulmonary edema, and on isolated dog lungs. The obtained results clearly illustrated that the method is sensitive enough to measure small changes in lung water content. In the radiometer method, on the other hand, both calculations and preliminary measurements in phantoms indicate that the natural microwave emission changes with lung water content and that conventional radiometry systems should be able to detect as little as three to four percent change in lung water content. Initial results from both methods, therefore, indicate the soundness of the basic ideas and justify further development of these methods for clinical use.</p>","PeriodicalId":76653,"journal":{"name":"The Journal of microwave power","volume":"18 3","pages":"265-75"},"PeriodicalIF":0.0000,"publicationDate":"1983-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1080/16070658.1983.11689331","citationCount":"29","resultStr":"{\"title\":\"Microwave methods of measuring changes in lung water.\",\"authors\":\"M F Iskander,&nbsp;C H Durney\",\"doi\":\"10.1080/16070658.1983.11689331\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Two microwave methods for measuring changes in lung water content have been investigated. The first is based on measuring changes in the phase of an active microwave signal transmitted through the thorax, while the other is based on measuring the natural microwave radiation emitted by the body with a radiometer. The feasibility of using the active microwave method is investigated by making measurements on phantoms, on anesthetized dogs with induced pulmonary edema, and on isolated dog lungs. The obtained results clearly illustrated that the method is sensitive enough to measure small changes in lung water content. In the radiometer method, on the other hand, both calculations and preliminary measurements in phantoms indicate that the natural microwave emission changes with lung water content and that conventional radiometry systems should be able to detect as little as three to four percent change in lung water content. Initial results from both methods, therefore, indicate the soundness of the basic ideas and justify further development of these methods for clinical use.</p>\",\"PeriodicalId\":76653,\"journal\":{\"name\":\"The Journal of microwave power\",\"volume\":\"18 3\",\"pages\":\"265-75\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1983-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1080/16070658.1983.11689331\",\"citationCount\":\"29\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"The Journal of microwave power\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1080/16070658.1983.11689331\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Journal of microwave power","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/16070658.1983.11689331","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 29

摘要

研究了两种测量肺含水量变化的微波方法。第一种是基于测量通过胸腔传输的有源微波信号的相位变化,而另一种是基于用辐射计测量人体发出的自然微波辐射。通过对狗的幻影、麻醉后的肺水肿和离体狗的肺进行测量,探讨了主动微波法的可行性。所获得的结果清楚地表明,该方法足够灵敏,可以测量肺含水量的微小变化。另一方面,在辐射计方法中,在模型中的计算和初步测量表明,自然微波发射随肺含水量的变化而变化,传统的辐射测量系统应该能够检测到肺含水量的3%至4%的变化。因此,两种方法的初步结果表明了基本思想的合理性,并证明了这些方法在临床应用中的进一步发展。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Microwave methods of measuring changes in lung water.

Two microwave methods for measuring changes in lung water content have been investigated. The first is based on measuring changes in the phase of an active microwave signal transmitted through the thorax, while the other is based on measuring the natural microwave radiation emitted by the body with a radiometer. The feasibility of using the active microwave method is investigated by making measurements on phantoms, on anesthetized dogs with induced pulmonary edema, and on isolated dog lungs. The obtained results clearly illustrated that the method is sensitive enough to measure small changes in lung water content. In the radiometer method, on the other hand, both calculations and preliminary measurements in phantoms indicate that the natural microwave emission changes with lung water content and that conventional radiometry systems should be able to detect as little as three to four percent change in lung water content. Initial results from both methods, therefore, indicate the soundness of the basic ideas and justify further development of these methods for clinical use.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信