{"title":"论耳部导电器手法对耳部脏器的损伤问题。","authors":"L Faltýnek, C Veselý","doi":"10.1159/000274933","DOIUrl":null,"url":null,"abstract":"The authors studied the effect on microphone potentials of one-minute mechanical manipulation of the conductive apparatus without damage to the stapes and opening of the vestibulum in guinea pigs. A decrease in microphone potentials with a subsequent slow restitution to the initial values was observed. The results of the mechanical manipulation were compared with the effect of white noise, intensity 120 dB. After one-minute manipulation, the decrease in the amplitude of microphone potentials and their restitution simulate the course of changes in microphone potentials after 5-minute deafening with white noise.","PeriodicalId":20405,"journal":{"name":"Practica oto-rhino-laryngologica","volume":"32 3","pages":"149-52"},"PeriodicalIF":0.0000,"publicationDate":"1970-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1159/000274933","citationCount":"1","resultStr":"{\"title\":\"On the problem of damage to the organ of Corti in manipulations on the conductive apparatus of the ear.\",\"authors\":\"L Faltýnek, C Veselý\",\"doi\":\"10.1159/000274933\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The authors studied the effect on microphone potentials of one-minute mechanical manipulation of the conductive apparatus without damage to the stapes and opening of the vestibulum in guinea pigs. A decrease in microphone potentials with a subsequent slow restitution to the initial values was observed. The results of the mechanical manipulation were compared with the effect of white noise, intensity 120 dB. After one-minute manipulation, the decrease in the amplitude of microphone potentials and their restitution simulate the course of changes in microphone potentials after 5-minute deafening with white noise.\",\"PeriodicalId\":20405,\"journal\":{\"name\":\"Practica oto-rhino-laryngologica\",\"volume\":\"32 3\",\"pages\":\"149-52\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1970-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1159/000274933\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Practica oto-rhino-laryngologica\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1159/000274933\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Practica oto-rhino-laryngologica","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1159/000274933","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
On the problem of damage to the organ of Corti in manipulations on the conductive apparatus of the ear.
The authors studied the effect on microphone potentials of one-minute mechanical manipulation of the conductive apparatus without damage to the stapes and opening of the vestibulum in guinea pigs. A decrease in microphone potentials with a subsequent slow restitution to the initial values was observed. The results of the mechanical manipulation were compared with the effect of white noise, intensity 120 dB. After one-minute manipulation, the decrease in the amplitude of microphone potentials and their restitution simulate the course of changes in microphone potentials after 5-minute deafening with white noise.