脉冲码调制遥测技术在滑雪损伤研究中的应用。一、仪器仪表。

Biotelemetry Pub Date : 1974-01-01
M L Hull, C D Mote
{"title":"脉冲码调制遥测技术在滑雪损伤研究中的应用。一、仪器仪表。","authors":"M L Hull,&nbsp;C D Mote","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Measurement problems can be classified into instrumentation, data transmission and recording, and analysis. This paper focuses on the transmission of multichannel, high-volume, high-frequency, high-accuracy data. Boot-ski dynamometer and skier velocity anemometer data provide 13 channels of max. 8-mV signals requiring 8-microvolt resolution or 4.45-Newton dynamometer resolution. The data transmission system features durability, power consumption approx. 10 Watts, weight 4.54 kp, range greater than 3,500 m, frequency response 250 Hz, accuracy 1 per cent, temperature stability, dynamic range plus or minus 2 inches. The transducer signals are ampflified to plus or minus 10 V for the 100-kbps PCM system. Special AC amplifiers, driven by an amplitude-stabilized power oscillator, were designed for elimination of radio frequency interference (RFI), improved stability and high signal/noise. Sixteen words are sequentially sampled at 521/sec-13 data, 2 frame counters, and 1 sync. The ground station consists of the PCM decoder with real-time capability and an analog tape recorder. Data is subsequently buffered and formatted onto digital tape by mini-computer.</p>","PeriodicalId":75602,"journal":{"name":"Biotelemetry","volume":"1 4","pages":"182-92"},"PeriodicalIF":0.0000,"publicationDate":"1974-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Pulse code modulation telemetry in ski injury research. I. Instrumentation.\",\"authors\":\"M L Hull,&nbsp;C D Mote\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Measurement problems can be classified into instrumentation, data transmission and recording, and analysis. This paper focuses on the transmission of multichannel, high-volume, high-frequency, high-accuracy data. Boot-ski dynamometer and skier velocity anemometer data provide 13 channels of max. 8-mV signals requiring 8-microvolt resolution or 4.45-Newton dynamometer resolution. The data transmission system features durability, power consumption approx. 10 Watts, weight 4.54 kp, range greater than 3,500 m, frequency response 250 Hz, accuracy 1 per cent, temperature stability, dynamic range plus or minus 2 inches. The transducer signals are ampflified to plus or minus 10 V for the 100-kbps PCM system. Special AC amplifiers, driven by an amplitude-stabilized power oscillator, were designed for elimination of radio frequency interference (RFI), improved stability and high signal/noise. Sixteen words are sequentially sampled at 521/sec-13 data, 2 frame counters, and 1 sync. The ground station consists of the PCM decoder with real-time capability and an analog tape recorder. Data is subsequently buffered and formatted onto digital tape by mini-computer.</p>\",\"PeriodicalId\":75602,\"journal\":{\"name\":\"Biotelemetry\",\"volume\":\"1 4\",\"pages\":\"182-92\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1974-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Biotelemetry\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biotelemetry","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

测量问题可分为仪器仪表、数据传输和记录以及分析。本文主要研究多通道、大容量、高频、高精度数据的传输。靴式滑雪测力仪和滑雪者速度风速计数据提供了13个通道的最大风速。8 mv信号需要8微伏分辨率或4.45牛顿测功机分辨率。该数据传输系统的特点是经久耐用,功耗约为。10瓦,重量4.54 kp,范围大于3500米,频率响应250赫兹,精度1%,温度稳定性,动态范围±2英寸。换能器信号被放大到±10v,用于100kbps的PCM系统。特殊的交流放大器,由一个振幅稳定的功率振荡器驱动,设计用于消除射频干扰(RFI),提高稳定性和高信号/噪声。16个字以521/秒-13个数据,2个帧计数器和1个同步顺序采样。地面站由具有实时能力的PCM解码器和模拟磁带录音机组成。数据随后被小型计算机缓冲并格式化到数字磁带上。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Pulse code modulation telemetry in ski injury research. I. Instrumentation.

Measurement problems can be classified into instrumentation, data transmission and recording, and analysis. This paper focuses on the transmission of multichannel, high-volume, high-frequency, high-accuracy data. Boot-ski dynamometer and skier velocity anemometer data provide 13 channels of max. 8-mV signals requiring 8-microvolt resolution or 4.45-Newton dynamometer resolution. The data transmission system features durability, power consumption approx. 10 Watts, weight 4.54 kp, range greater than 3,500 m, frequency response 250 Hz, accuracy 1 per cent, temperature stability, dynamic range plus or minus 2 inches. The transducer signals are ampflified to plus or minus 10 V for the 100-kbps PCM system. Special AC amplifiers, driven by an amplitude-stabilized power oscillator, were designed for elimination of radio frequency interference (RFI), improved stability and high signal/noise. Sixteen words are sequentially sampled at 521/sec-13 data, 2 frame counters, and 1 sync. The ground station consists of the PCM decoder with real-time capability and an analog tape recorder. Data is subsequently buffered and formatted onto digital tape by mini-computer.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信